{"id":44861,"date":"2026-11-25T13:05:41","date_gmt":"2026-11-25T05:05:41","guid":{"rendered":"https:\/\/www.evb.com\/?p=44861"},"modified":"2026-11-25T13:05:50","modified_gmt":"2026-11-25T05:05:50","slug":"pull-through-ev-charging-station-design","status":"publish","type":"post","link":"https:\/\/www.evb.com\/da\/pull-through-ev-charging-station-design\/","title":{"rendered":"Planl\u00e6gning af gennemk\u00f8rselsladestationer: m\u00e5l, indretning &amp; opdelt DC-udstyr til lastbiler &amp; vogntog"},"content":{"rendered":"<style>\n.evb-pullthrough-article{font-family:inherit;color:#1f1f1f;font-size:17px;line-height:1.8;overflow-wrap:break-word}\n.evb-pullthrough-article h2,.evb-pullthrough-article h3{color:#0b2239;line-height:1.3}\n.evb-pullthrough-article h2{font-size:30px;font-weight:800;margin:44px 0 14px}\n.evb-pullthrough-article h3{font-size:22px;font-weight:700;margin:26px 0 10px}\n.evb-pullthrough-article p{margin:0 0 18px;color:#3f4852}\n.evb-pullthrough-article a{color:#185fa5;text-decoration:underline;text-underline-offset:2px}\n.evb-pullthrough-article a:focus-visible,.evb-pullthrough-article .evb-table-wrap:focus-visible{outline:2px solid #185fa5;outline-offset:3px}\n.evb-pullthrough-article .evb-eeat-line{margin:0 0 26px;color:#667584;font-size:15px;line-height:1.7}\n.evb-pullthrough-article .evb-article-intro{border-left:4px solid #185fa5;background:#f4f8fc;padding:16px 20px;border-radius:0 8px 8px 0;margin:0 0 24px;font-size:17.5px;line-height:1.72;color:#172b3e}\n.evb-pullthrough-article .evb-example-box{background:#f0f7fb;border:1px solid #cce0ee;border-radius:8px;padding:15px 18px;margin:0 0 22px;font-size:16px;color:#163146}\n.evb-pullthrough-article ul,.evb-pullthrough-article ol{margin:0 0 18px 22px;padding:0}\n.evb-pullthrough-article li{margin:0 0 9px;color:#3f4852}\n.evb-pullthrough-article .evb-table-title{margin:20px 0 8px;color:#0b2239;font-weight:700;font-size:15.5px;line-height:1.45}\n.evb-pullthrough-article .evb-table-wrap{max-width:100%;overflow-x:auto;margin:0 0 12px;-webkit-overflow-scrolling:touch}\n.evb-pullthrough-article .evb-table{width:100%;min-width:620px;border-collapse:collapse;font-size:15px}\n.evb-pullthrough-article .evb-table th,.evb-pullthrough-article .evb-table td{border:1px solid #dfe6ed;padding:11px 13px;text-align:left;vertical-align:top}\n.evb-pullthrough-article .evb-table thead th{background:#0b2239;color:#fff;font-size:13.5px;letter-spacing:.02em}\n.evb-pullthrough-article .evb-table tbody th{background:#f7fafe;color:#0b2239;font-weight:700}\n.evb-pullthrough-article .evb-table tbody tr:nth-child(even) td{background:#fafcfe}\n.evb-pullthrough-article .evb-table-note{font-size:13px;color:#526171;margin:0 0 24px}\n.evb-pullthrough-article .evb-checklist{background:#f7f9fc;border:1px solid #d9e3ee;border-radius:8px;padding:18px 22px;margin:22px 0 26px}\n.evb-pullthrough-article .evb-checklist h3,.evb-pullthrough-article .evb-callout h3{margin-top:0}\n.evb-pullthrough-article .evb-checklist>:last-child,.evb-pullthrough-article .evb-callout>:last-child{margin-bottom:0}\n.evb-pullthrough-article .evb-callout{background:#0b2239;color:#fff;border-radius:10px;padding:24px 26px;margin:32px 0}\n.evb-pullthrough-article .evb-callout h3,.evb-pullthrough-article .evb-callout p{color:#f1f6fb}\n.evb-pullthrough-article .evb-callout a{color:#9fd4ff;font-weight:600}\n.evb-pullthrough-article .evb-cta-btn{display:inline-block;margin-top:8px;background:#185fa5;color:#fff!important;text-decoration:none!important;padding:11px 22px;border-radius:7px;font-weight:700}\n.evb-pullthrough-article .evb-cta-btn:hover{background:#124c85}\n.evb-pullthrough-article .evb-article-figure{max-width:920px;margin:24px 0 28px}\n.evb-pullthrough-article .evb-article-figure a{display:block}\n.evb-pullthrough-article .evb-article-figure img{display:block;width:100%;height:auto;border-radius:10px;border:1px solid #dce5ee}\n.evb-pullthrough-article figcaption{margin-top:9px;color:#526171;font-size:.88em;line-height:1.55}\n@media(max-width:768px){\n  .evb-pullthrough-article{font-size:16px}\n  .evb-pullthrough-article h2{font-size:24px;margin:34px 0 12px}\n  .evb-pullthrough-article h3{font-size:19px}\n}\n<\/style>\n<div class=\"evb-article-wrap evb-pullthrough-article\" lang=\"en\">\n  <div class=\"evb-eeat-line\">EVB.COM &middot; Forfatter: EVB-teamet for ladel\u00f8sninger &middot; Opdateret november 2026 &middot; 15 minutters l\u00e6setid &middot; Gennemk\u00f8rselsladning til elbiler &middot; Erhvervsm\u00e6ssig DC-hurtigladning &middot; El-lastbiler<\/div>\n\n  <p class=\"evb-article-intro\"><strong>Gennemk\u00f8rselsladestationer giver el-lastbiler og vogntog mulighed for at k\u00f8re lige ind og ud uden at koble anh\u00e6ngeren fra eller bakke.<\/strong> Dimension\u00e9r hver lige ladeplads efter det faktiske dimensionerende k\u00f8ret\u00f8js l\u00e6ngde med separate stopmargener foran og bagved. Kontroll\u00e9r herefter separat anh\u00e6ngerens sporafvigelse, bagendens udsving og overgangen ved ind- og udk\u00f8rsel. For tilg\u00e6ngelige gennemk\u00f8rselspladser i USA anbefaler U.S. Access Board mindst <strong>16 ft (4,880 mm)<\/strong> til ladepladsens bredde og kabelforbindelse til et k\u00f8ret\u00f8j placeret <strong>5 ft (1,525 mm)<\/strong> v\u00e6k. Ved at placere ensretterskabe adskilt fra de smalle DC-ladestandere undg\u00e5r man pladskr\u00e6vende omformere p\u00e5 smalle lade\u00f8er.<\/p>\n\n  <p>Almindelige personb\u00e5se til forl\u00e6ns eller bagl\u00e6ns parkering passer ikke til elektriske pickupper med anh\u00e6nger og s\u00e6ttevognstog. F\u00f8rerne ender med at optage flere pladser, blokere k\u00f8regange eller springe ladestationen over. Denne vejledning gennemg\u00e5r dimensionering, ensrettede k\u00f8rselsforl\u00f8b, tilg\u00e6ngelighedsm\u00e5l, p\u00e5k\u00f8rselsbeskyttelse, kontrol af blandede tank- og ladeanl\u00e6g samt valg af opdelt DC-ladeudstyr.<\/p>\n\n  <div class=\"evb-example-box\"><strong>Hvad skal placeres p\u00e5 lade\u00f8en?<\/strong> I integrerede ladere sidder effektmoduler og styring i samme kabinet. Med EVB-systemet p\u00e5 720 kW, <strong>BSDC720-250D5<\/strong> , er ensretterskab og ladeterminaler adskilt. Skabet p\u00e5 <strong>1,700 &times; 1,000 &times; 2,150 mm<\/strong> (&le;1,100 kg) kan st\u00e5 p\u00e5 et separat fundament, mens kun terminalen p\u00e5 <strong>600 &times; 230 &times; 1,700 mm<\/strong> (&le;110 kg) placeres p\u00e5 \u00f8en. Afs\u00e6t plads til fundament og pullerter, \u00e5bne skabsd\u00f8re og teknikerens arbejdsomr\u00e5de.<\/div>\n\n  <p>Se ogs\u00e5 EVB\u2019s vejledninger om <a href=\"https:\/\/www.evb.com\/da\/ada-ev-charging-requirements\/\">tilg\u00e6ngelig opladning af elk\u00f8ret\u00f8jer<\/a>, <a href=\"https:\/\/www.evb.com\/da\/ev-charging-station-signage\/\">skiltning ved ladestationer<\/a>, <a href=\"https:\/\/www.evb.com\/da\/ev-charger-cable-management\/\">kabelf\u00f8ring ved erhvervsladere<\/a>, og <a href=\"https:\/\/www.evb.com\/da\/fleet-depot-charging-power-requirements\/\">og effektbehov i fl\u00e5dedepoter<\/a>.<\/p>\n\n  <h2 id=\"when-pull-through-bays-are-required\">1. Hvorn\u00e5r gennemk\u00f8rselspladser eller bakkepladser er bedst<\/h2>\n\n  <p>Hver gennemk\u00f8rselsbane kr\u00e6ver sammenh\u00e6ngende ind- og udk\u00f8rsel i stedet for \u00e9n blind k\u00f8regang. En gennemk\u00f8rselsladeplads fylder derfor v\u00e6sentligt mere belagt areal end en almindelig vinkelret plads. Bestem antallet ud fra eftersp\u00f8rgslen p\u00e5 stedet:<\/p>\n\n  <ul>\n    <li><strong>Fasts\u00e6t antallet efter spidsbelastningen:<\/strong> Beregn andelen af gennemk\u00f8rselsbaner ud fra forventede ankomster af vogntog og lastbiler pr. time, gennemsnitlig ladetid og den h\u00f8jeste \u00f8nskede ventetid. Motorvejsanl\u00e6g til fritidsvogne og godskorridorer beh\u00f8ver en st\u00f8rre andel end butiksladepladser i byomr\u00e5der.<\/li>\n    <li><strong>Tilpas logistikdepoter til driftsm\u00f8nstret:<\/strong> Ensrettede gennemk\u00f8rselspladser letter mellemladning i 30\u201390 minutter under et skift. Natdepoter med l\u00e6ngere ophold kan ogs\u00e5 bruge pladser til forl\u00e6ns eller bagl\u00e6ns indk\u00f8rsel, n\u00e5r bakkearealer eller k\u00f8rselsassistenter er indarbejdet i anl\u00e6gget.<\/li>\n    <li><strong>Undg\u00e5 blokering i ensrettede baner med pladser i forl\u00e6ngelse af hinanden:<\/strong> I en s\u00e5dan bane uden overhalingsmulighed g\u00e6lder: <strong>er det bageste k\u00f8ret\u00f8j f\u00e6rdigt f\u00f8rst, m\u00e5 det vente p\u00e5 k\u00f8ret\u00f8jet foran<\/strong> f\u00f8r det kan k\u00f8re ud. Det forreste k\u00f8ret\u00f8j kan k\u00f8re lige ud. Giv hver offentlig gennemk\u00f8rselsplads en selvst\u00e6ndig lige udk\u00f8rsel eller en sidebane.<\/li>\n    <li><strong>Koordin\u00e9r tanke- og ladeomr\u00e5der tidligt:<\/strong> Er der diesel- eller benzinstandere p\u00e5 samme grund, skal tegninger over farezoner for flydende br\u00e6ndstoffer og k\u00f8omr\u00e5der for tunge k\u00f8ret\u00f8jer kortl\u00e6gges, f\u00f8r ladepladserne fastl\u00e6gges.<\/li>\n  <\/ul>\n\n  <h2 id=\"pull-through-bay-dimensions-and-site-geometry\">2. Indretning og m\u00e5l for gennemk\u00f8rselsladestationer<\/h2>\n\n  <p>Et enkelt s\u00e6t m\u00e5l passer ikke til alle k\u00f8ret\u00f8jer og regels\u00e6t. Fastl\u00e6g den lige ladeplads ud fra en bestemt k\u00f8ret\u00f8jskombination og stopmargener: <strong>L\u00e6ngde p\u00e5 lige ladeplads = samlet l\u00e6ngde p\u00e5 dimensionerende k\u00f8ret\u00f8j + stopmargin foran + frirum bagved<\/strong>. K\u00f8r derefter en selvst\u00e6ndig k\u00f8rekurvesimulering, f.eks. AutoTURN, for at kontrollere anh\u00e6ngerens sporafvigelse, bagudh\u00e6ngets udsving og tilslutningen ved ind- og udk\u00f8rsel.<\/p>\n\n  <figure class=\"evb-article-figure\">\n    <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/pull-through-ev-charging-bay-geometry-plan-v2.webp\" target=\"_blank\" rel=\"noopener\" title=\"\u00c5bn planen over gennemk\u00f8rsel og k\u00f8rekurver i fuld opl\u00f8sning\">\n      <img src=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/pull-through-ev-charging-bay-geometry-plan-v2.webp\" alt=\"Sprogneutral plantegning af ensrettede gennemk\u00f8rselsbaner fra venstre mod h\u00f8jre. En pickup med anh\u00e6nger og et s\u00e6ttevognstog deler en smal lade\u00f8. Henvisningerne 1 til 6 viser ensvendte k\u00f8ret\u00f8jsfronter og udk\u00f8rsler, anh\u00e6ngerens k\u00f8rekurve, sideafstand til ladestanderen med kabel frem til k\u00f8ret\u00f8jets ladeindtag, sideplacerede pullerter, ensretterskabets separate fundament og underjordisk DC-kabelf\u00f8ring.\" width=\"1600\" height=\"900\" loading=\"lazy\" decoding=\"async\" \/>\n    <\/a>\n    <figcaption>Plantegning af ensrettet gennemk\u00f8rsel. K\u00f8ret\u00f8jsfronter, pile og udk\u00f8rsler er orienteret fra venstre mod h\u00f8jre. Henvisninger: <strong>&#9312;<\/strong> ensrettet indk\u00f8rsel, lige ladeplads og s\u00e6rskilt lige udk\u00f8rsel uden blokering mellem k\u00f8ret\u00f8jer bag hinanden; <strong>&#9313;<\/strong> k\u00f8rekurven er s\u00e6rskilt kontrolleret for anh\u00e6ngerens sporafvigelse og bagendens udsving; <strong>&#9314;<\/strong> sideafstand mellem k\u00f8ret\u00f8j og ladestander. U.S. Access Board anbefaler kabelforbindelse til et k\u00f8ret\u00f8j 5 ft \/ 1,525 mm v\u00e6k. Ladekablet f\u00f8res til k\u00f8ret\u00f8jets faktiske ladeindtag; <strong>&#9315;<\/strong> sideplacerede beskyttelsespullerter omkring smalle, separate DC-ladestandere p\u00e5 lade\u00f8en; <strong>&#9316;<\/strong> separat fundament til modul\u00e6rt ensretterskab uden for lade\u00f8en; <strong>&#9317;<\/strong> underjordisk r\u00f8r til DC-f\u00f8dekabel. Ladepladsernes n\u00f8jagtige m\u00e5l afh\u00e6nger af beregningen for det dimensionerende k\u00f8ret\u00f8j og de lokale standarder i tabellen nedenfor.<\/figcaption>\n  <\/figure>\n\n  <p class=\"evb-table-title\" id=\"tbl-dimensions-title\">Regneeksempler for gennemk\u00f8rselspladser &amp; grundlag for anl\u00e6gskontrol (ikke faste lovkrav)<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-dimensions-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">Planl\u00e6gningskontrol<\/th>\n          <th scope=\"col\">Eksempel A: let pickup + lastanh\u00e6nger<\/th>\n          <th scope=\"col\">Eksempel B: EU-s\u00e6ttevognstog p\u00e5 16.5 m (<a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/1996\/53\/oj\/eng\" rel=\"nofollow\" style=\"color:#9fd4ff\">Direktiv 96\/53\/EC<\/a>)<\/th>\n          <th scope=\"col\">Eksempel C: amerikansk tr\u00e6kker + 53 ft s\u00e6ttevogn<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\">Valgt k\u00f8ret\u00f8jskombination (samlet l\u00e6ngde)<\/th>\n          <td>50 ft (15.2 m) i eksemplet (~20 ft pickup + 30 ft tilkoblet anh\u00e6nger; beregn igen ved mere end 50 ft)<\/td>\n          <td>16.50 m (54.1 ft) for et s\u00e6ttevognstog efter direktiv 96\/53\/EC, bilag I (vogntog op til 18.75 m)<\/td>\n          <td>~73.5 ft (22.4 m) for en typisk amerikansk fjerntransporttr\u00e6kker + 53 ft s\u00e6ttevogn (kontroll\u00e9r delstatens l\u00e6ngdegr\u00e6nser)<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Beregnet l\u00e6ngde p\u00e5 lige ladeplads (k\u00f8ret\u00f8j + margin foran + margin bagved)<\/th>\n          <td><strong>60 ft (18.3 m)<\/strong> = 50 ft vogntog + 5 ft stopmargin foran + 5 ft frirum bagved (beregn igen ved l\u00e6ngere anh\u00e6ngere)<\/td>\n          <td><strong>21.5 m (~70.5 ft)<\/strong> = 16.5 m lastbil + 2.5 m margin foran + 2.5 m frirum bagved (udvid til vogntog p\u00e5 18.75 m)<\/td>\n          <td><strong>93.5 ft (~28.5 m)<\/strong> = 73.5 ft vogntog + 10 ft margin foran + 10 ft frirum bagved; tilf\u00f8j separate, lige ind- og udk\u00f8rselsforl\u00f8b<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Ladepladsbredde &amp; regionale tilg\u00e6ngelighedskrav<\/th>\n          <td>Tilg\u00e6ngelig amerikansk gennemk\u00f8rselsplads: <strong>&ge;16 ft (4,880 mm)<\/strong> if\u00f8lge <a href=\"https:\/\/www.access-board.gov\/tad\/ev\/#pull-through-ev-charging-stations-design\" rel=\"nofollow\">U.S. Access Board<\/a>. Uden for USA f\u00f8lges de nationale krav til k\u00f8rebane og tilg\u00e6ngelighed.<\/td>\n          <td>F\u00f8lg nationale EU-krav til k\u00f8rebanebredde for tunge k\u00f8ret\u00f8jer og lokale tilg\u00e6ngelighedsregler. Den amerikanske anbefaling p\u00e5 16 ft g\u00e6lder ikke generelt i Europa.<\/td>\n          <td>Tilg\u00e6ngelig amerikansk gennemk\u00f8rselsplads: <strong>&ge;16 ft (4,880 mm)<\/strong> if\u00f8lge U.S. Access Board; kontroll\u00e9r behovet for st\u00f8rre frirum, n\u00e5r spejle og f\u00f8rerhustrin p\u00e5 tunge k\u00f8ret\u00f8jer er afg\u00f8rende.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Fri h\u00f8jde (overd\u00e6kning, belysning &amp; kabelarme)<\/th>\n          <td>Kontroll\u00e9r h\u00f8je campingvogne og tagb\u00f8jler i forhold til den laveste overd\u00e6kningsbj\u00e6lke eller oph\u00e6ngte kabelarm.<\/td>\n          <td>Over EU\u2019s lovbestemte k\u00f8ret\u00f8jsh\u00f8jde p\u00e5 4.00 m (direktiv 96\/53\/EC, bilag I) plus lokal sikkerhedsmargin til broer eller overd\u00e6kning og plads til fast udstyr over k\u00f8rebanen.<\/td>\n          <td><strong>Ingen f\u00e6lles amerikansk f\u00f8deral h\u00f8jdegr\u00e6nse for erhvervsk\u00f8ret\u00f8jer<\/strong> (<a href=\"https:\/\/ops.fhwa.dot.gov\/freight\/publications\/size_regs_final_rpt\/index.htm\" rel=\"nofollow\">FHWA<\/a>); kontroll\u00e9r delstatens h\u00f8jdegr\u00e6nser (typisk 13.5\u201314 ft), de anvendte ruter og k\u00f8ret\u00f8jer samt den laveste del af overd\u00e6kningen.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Kontrol af sving og k\u00f8rekurver &amp; man\u00f8vreareal<\/th>\n          <td>Modell\u00e9r hele anh\u00e6ngerens sporafvigelse og bagendens udsving fra kantstenss\u00e6nkning til udk\u00f8rsel med k\u00f8rekurvesoftware.<\/td>\n          <td>Direktiv 96\/53\/EC, bilag I &sect;1.5, specificerer k\u00f8ret\u00f8jets drejeevne (<strong>12.50 m ydre radius \/ 5.30 m indre radius<\/strong>). Det er et k\u00f8ret\u00f8jsm\u00e5l og <em>ikke<\/em> en svingradius til anl\u00e6gsplanen. Modell\u00e9r bredere kurver, s\u00e5 der er sikkert frirum.<\/td>\n          <td>Modell\u00e9r s\u00e6ttevognstogets n\u00f8jagtige akselafh\u00e6ngige sporafvigelse, forendens udvendige overh\u00e6ng og overgangene med AutoTURN eller tilsvarende software.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">Eksemplerne viser, hvordan l\u00e6ngden udledes af k\u00f8ret\u00f8jernes geometri og udtrykkelige margener. Kontroll\u00e9r altid regionale og nationale m\u00e5lgr\u00e6nser (<a href=\"https:\/\/ops.fhwa.dot.gov\/freight\/publications\/size_regs_final_rpt\/index.htm\" rel=\"nofollow\">FHWA: dimensioner &amp; v\u00e6gt<\/a>; <a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/1996\/53\/oj\/eng\" rel=\"nofollow\">Direktiv 96\/53\/EC<\/a>), <a href=\"https:\/\/driveelectric.gov\/\" rel=\"nofollow\">F\u00e6lles amerikansk kontor<\/a> , retningslinjer og k\u00f8rekurveskabeloner inden anl\u00e6gsarbejdet.<\/p>\n\n  <h3>Regler for k\u00f8rselsforl\u00f8b, k\u00f8areal &amp; vejvisning<\/h3>\n  <ul>\n    <li><strong>H\u00e5ndh\u00e6v ensretning:<\/strong> Brug k\u00f8rebanepile med h\u00f8j kontrast, p\u00e5malede stoplinjer ud for de typiske ladeindtagspositioner og tydelig retningsskiltning efter <a href=\"https:\/\/mutcd.fhwa.dot.gov\/\" rel=\"nofollow\">FHWA MUTCD<\/a>, s\u00e5 f\u00f8rerne ikke skal vende eller bakke uden udsyn under overd\u00e6kningen.<\/li>\n    <li><strong>Dimension\u00e9r k\u00f8baner uden for motorvejen:<\/strong> Indret et s\u00e6rskilt k\u00f8areal p\u00e5 grunden foran ladepladserne, is\u00e6r ved godskorridorer. Lastbiler i k\u00f8 m\u00e5 ikke blokere motorvejsramper eller tilst\u00f8dende baner.<\/li>\n    <li><strong>Plac\u00e9r s\u00f8jler uden for k\u00f8rekurverne:<\/strong> Flugt overd\u00e6kningens s\u00f8jler med lade\u00f8erne, ikke med de indvendige indk\u00f8rselshj\u00f8rner, hvor anh\u00e6ngerens bagaksel kan afvige s\u00e5 meget, at den rammer fritst\u00e5ende st\u00e5ls\u00f8jler.<\/li>\n  <\/ul>\n\n  <h2 id=\"island-protection-accessibility-and-fuel-separation\">3. Tilg\u00e6ngelighed, p\u00e5k\u00f8rselsbeskyttelse &amp; kontrol af blandede tank- og ladeanl\u00e6g<\/h2>\n\n  <p>P\u00e5 gennemk\u00f8rsels\u00f8er m\u00f8des tilg\u00e6ngelighed og p\u00e5k\u00f8rselsbeskyttelse. Ved tankanl\u00e6g med forskellige br\u00e6ndstoffer skal omr\u00e5der med ant\u00e6ndelige dampe ogs\u00e5 klassificeres. Kontroll\u00e9r hvert krav separat efter det relevante regels\u00e6t.<\/p>\n\n  <figure class=\"evb-article-figure\">\n    <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/pull-through-island-clearance-and-protection-section-v2.webp\" target=\"_blank\" rel=\"noopener\" title=\"\u00c5bn diagrammet over tilg\u00e6ngelig adgang og kabelr\u00e6kkevidde i fuld opl\u00f8sning\">\n      <img src=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/pull-through-island-clearance-and-protection-section-v2.webp\" alt=\"Sprogneutral teknisk tegning af en k\u00f8restolsbruger ved en niveaufri, separat DC-ladestander ved en gennemk\u00f8rselsbane. Henvisningerne 1 til 5 viser fri gulvplads, forl\u00e6ns eller parallel adgang, h\u00f8jdeomr\u00e5de for sk\u00e6rm og stikholder, sideplacerede pullerter og ladekablets vej frem til k\u00f8ret\u00f8jets ladeindtag.\" width=\"1600\" height=\"900\" loading=\"lazy\" decoding=\"async\" \/>\n    <\/a>\n    <figcaption>Tilg\u00e6ngelig adgang og kabelr\u00e6kkevidde ved et niveaufrit gennemk\u00f8rselsanl\u00e6g. Henvisninger: <strong>&#9312;<\/strong> frit gulv- eller terr\u00e6nareal (ADA &sect;305) i terr\u00e6nniveau uden h\u00e6vet kantsten eller med niveaufri kantstenss\u00e6nkning; <strong>&#9313;<\/strong> forl\u00e6ns eller parallel k\u00f8restolsadgang kontrolleret s\u00e6rskilt for eventuel forhindringsdybde; <strong>&#9314;<\/strong> r\u00e6kkeviddezone for sk\u00e6rm, betalingsterminal og stikholder (ADA &sect;308); <strong>&#9315;<\/strong> sideplacerede st\u00e5lpullerter beskytter ladestanderen uden at blokere det frie areal og r\u00e6kkevidden foran den; <strong>&#9316;<\/strong> ladekabel f\u00f8rt fra standerens kabeludgang via kabeloprullerens tr\u00e6kvej til k\u00f8ret\u00f8jets ladeindtag. Kontroll\u00e9r r\u00e6kkevidden ved det planlagte stoppunkt med margin for parkeringsafvigelser. U.S. Access Board anbefaler forbindelse ved 5 ft \/ 1,525 mm afstand.<\/figcaption>\n  <\/figure>\n\n  <h3>Tre s\u00e6rskilte krav fra U.S. Access Board &amp; kontrol efter ADA kapitel 3<\/h3>\n  <p><a href=\"https:\/\/www.access-board.gov\/tad\/ev\/#pull-through-ev-charging-stations-design\" rel=\"nofollow\">U.S. Access Boards vejledning om gennemk\u00f8rselsladning<\/a> beskriver tre forskellige forhold, der skal kontrolleres s\u00e6rskilt:<\/p>\n  <ul>\n    <li><strong>Afm\u00e6rkning:<\/strong> P\u00e5 gennemk\u00f8rselsladestationer til elk\u00f8ret\u00f8jer beh\u00f8ver ladepladserne ikke individuel opstregning eller afm\u00e6rkning.<\/li>\n    <li><strong>Ladepladsens bredde:<\/strong> S\u00f8rg for mindst <strong>16 ft (4,880 mm)<\/strong> bredde til ladepladsen. (Det er U.S. Access Boards anbefaling; i Europa og andre regioner f\u00f8lges national lovgivning om tilg\u00e6ngelighed.)<\/li>\n    <li><strong>Kabelr\u00e6kkevidde:<\/strong> Ladekablet skal kunne forbindes med et k\u00f8ret\u00f8j placeret <strong>5 ft (1,525 mm)<\/strong> v\u00e6k.<\/li>\n  <\/ul>\n\n  <p>Separat g\u00e6lder efter <a href=\"https:\/\/www.access-board.gov\/ada\/chapter\/ch03\/#308-reach-ranges\" rel=\"nofollow\">ADA-standardernes kapitel 3 (&sect;305 og &sect;308)<\/a>, at tilg\u00e6ngelige ladestandere kr\u00e6ver uhindret <strong>frit gulv- eller terr\u00e6nareal (&sect;305)<\/strong>. Undg\u00e5 derfor h\u00f8je kantsten, eller lav en niveaufri kantstenss\u00e6nkning. Kontroll\u00e9r ogs\u00e5 <strong>adgangsretningen<\/strong> (forl\u00e6ns eller parallel), <strong>r\u00e6kkevidden hen over eventuelle forhindringer<\/strong>, og <strong>betjeningsdelenes h\u00f8jde (&sect;308)<\/strong> (h\u00f8jst 48 in \/ 1,220 mm ved uhindret forl\u00e6ns eller parallel adgang; gr\u00e6nsen afh\u00e6nger af adgangsretning og forhindringsdybde). Hvis de lokale brandmyndigheder h\u00e5ndh\u00e6ver <strong>IFC-afsnit 312<\/strong>, er kravene til beskyttelsespullerter (IFC &sect;312.2: betonfyldt st\u00e5lr\u00f8r &ge;4 in \/ 102 mm, centerafstand &le;4 ft OC, mindst 3 ft (914 mm) dybt i betonfundamenter med mindst 15 in (381 mm) diameter, h\u00f8jde &ge;3 ft og vandret afstand &ge;3 ft fra det beskyttede objekt) afg\u00f8rende for vandret beskyttelse. ADA &sect;305\/&sect;308 regulerer frit gulvareal, adgangsretning, r\u00e6kkeviddedybde og betjeningsh\u00f8jde. Kontroll\u00e9r alle fire ADA-forhold sammen med p\u00e5k\u00f8rselsbeskyttelsen. Plac\u00e9r pullerterne ved standerens til- og frak\u00f8rselssider som anbefalet af U.S. Access Board, eller indsend en AHJ-godkendt <strong>IFC &sect;312.3<\/strong> funktionsbaseret barriere (eller brug kriterierne fra 2012-udgaven p\u00e5 &ge;36 in \/ 12,000 lb, hvor de stadig g\u00e6lder lokalt).<\/p>\n\n  <h3>Overholdelsesmatrix med fire niveauer (Nordamerika &amp; Europa)<\/h3>\n\n  <p class=\"evb-table-title\" id=\"tbl-standards-title\">Fire kravsniveauer ved gennemk\u00f8rselsanl\u00e6g med DC-ladning<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-standards-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">Kravsniveau<\/th>\n          <th scope=\"col\">Nordamerika (USA \/ Canada)<\/th>\n          <th scope=\"col\">Europa \/ internationalt (IEC \/ EU)<\/th>\n          <th scope=\"col\">Teknisk kontrol p\u00e5 stedet<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\">1. Anl\u00e6gsforhold, tilg\u00e6ngelighed &amp; korridorm\u00e5l<\/th>\n          <td><a href=\"https:\/\/www.access-board.gov\/tad\/ev\/#pull-through-ev-charging-stations-design\" rel=\"nofollow\">U.S. Access Boards vejledning om opladning af elk\u00f8ret\u00f8jer<\/a>; <a href=\"https:\/\/www.access-board.gov\/ada\/chapter\/ch03\/#308-reach-ranges\" rel=\"nofollow\">ADA &sect;305\/&sect;308<\/a>; <a href=\"https:\/\/mutcd.fhwa.dot.gov\/\" rel=\"nofollow\">FHWA MUTCD<\/a>; delstaternes krav til k\u00f8ret\u00f8jsm\u00e5l<\/td>\n          <td><a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2023\/1804\/oj\" rel=\"nofollow\">EU AFIR (forordning 2023\/1804)<\/a> Art. 4(1)(a\u2013d) &amp; 4(2) om ladeparker til tunge k\u00f8ret\u00f8jer i hver k\u00f8rselsretning: 15% (inden 2025) og 50% (inden 2027) g\u00e6lder samlet TEN-T-vejl\u00e6ngde pr. medlemsstat (d\u00e6kket i 2027: <strong>hovednettet<\/strong> &ge;2.8 MW med &ge;2 &times; 350 kW; <strong>det samlede net<\/strong> &ge;1.4 MW med &ge;1 &times; 350 kW); inden 2030 fuld d\u00e6kning af <strong>hovednettet<\/strong> (&le;60 km) &ge;3.6 MW (&ge;2 &times; 350 kW) og <strong>det samlede net<\/strong> (&le;100 km) &ge;1.5 MW (&ge;1 &times; 350 kW); nationale regler om adgang<\/td>\n          <td>Kontroll\u00e9r banevidde, niveaufrit terr\u00e6n eller kantstenss\u00e6nkning, frit areal efter ADA &sect;305\/&sect;308 &amp; r\u00e6kkevidde, k\u00f8rekurver og ensretningsskilte s\u00e6rskilt. En ekstra bred ladeplads erstatter ikke en kantstenss\u00e6nkning.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">2. Sikkerhed for komplet EVSE-enhed &amp; protokoller<\/th>\n          <td>UL 2202 (DC-EVSE); certificering for NACS \/ CCS1 \/ MCS-stik; muligheder for OCPP &amp; ISO 15118<\/td>\n          <td><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/33644\" rel=\"nofollow\">EN IEC 61851-1<\/a> &amp; IEC 61851-23 \/ -24; EU-overensstemmelseserkl\u00e6ring (CE); muligheder for ISO 15118-2 \/ -20 &amp; MID\/PTB<\/td>\n          <td>Bekr\u00e6ft den pr\u00e6cise regionale AC-netsp\u00e6nding, f.eks. den UL-listede nordamerikanske variant p\u00e5 480 V AC sammenlignet med 380\u2013415 V AC efter IEC\/CE. Kontroll\u00e9r protokolmulighederne pr. varenummer i tilbudsanmodningen.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">3. Elinstallation &amp; p\u00e5k\u00f8rselsbeskyttelse<\/th>\n          <td><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" rel=\"nofollow\">NFPA 70 (NEC)<\/a> Art. 625 (dimensionering til vedvarende belastning ved 125%, &sect;625.43 frakobling), &sect;110.26 arbejdsareal; IFC &sect;312; canadisk elinstallationsforskrift del I<\/td>\n          <td><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">IEC 60364-7-722:2018<\/a>; IEC 60529 (IP) &amp; IEC 62262 (IK) kun for kabinetters beskyttelse mod indtr\u00e6ngning og slag; nationale regler om barrierer<\/td>\n          <td>Kontroll\u00e9r arbejdsarealet omkring ensretterskabe og d\u00f8re. IP- og IK-klassifikation dokumenterer ikke korrosionsbestandighed ved kysten. Kontroll\u00e9r overfladebehandlingen s\u00e6rskilt.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">4. Klassificering af farezoner (blandede br\u00e6ndstoffer + elk\u00f8ret\u00f8jer)<\/th>\n          <td>Lokalt anvendte udgaver af <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-30a-standard-development\/30a\" rel=\"nofollow\">NFPA 30A<\/a>, NEC Art. 514 (tabeller til farezoneklassificering &amp; &sect;514.11 frakobling af br\u00e6ndstofstandere) og NEC &sect;625.28<\/td>\n          <td><a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/1999\/92\/oj\/eng\" rel=\"nofollow\">EU\u2019s ATEX-arbejdspladsdirektiv 1999\/92\/EC<\/a>, direktiv 2014\/34\/EU og nationale afstandskrav for tankanl\u00e6g<\/td>\n          <td>Standardudstyr til DC-opladning, EVSE, er beregnet til <strong>ufarlige (ikke-klassificerede) omr\u00e5der<\/strong>. Reglerne adskiller sig i USA og EU. Kontroll\u00e9r udstyret og hele kablets bev\u00e6gelsesomr\u00e5de i forhold til de faktiske br\u00e6ndstoffer (benzin eller diesel), p\u00e5fyldnings- og udluftningspunkter, den anvendte forskriftsudgave og det farezonekort, som AHJ har godkendt.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">Bekr\u00e6ft altid den lokale forskriftsudgave, farezonekortet for det konkrete br\u00e6ndstof og netselskabets tilslutningskrav med den kompetente myndighed (AHJ).<\/p>\n\n  <h2 id=\"charge-port-placement-cable-reach-and-mcs\">4. Ladeindtagets placering, kabelr\u00e6kkevidde &amp; klarg\u00f8ring til MCS<\/h2>\n\n  <p>En bred gennemk\u00f8rselsbane fungerer ikke, hvis kablerne sl\u00e6ber hen over bel\u00e6gningen eller kun vanskeligt n\u00e5r ladeindtagene:<\/p>\n\n  <ol>\n    <li><strong>CharIN MCS-vejledning om ladeindtag sammenholdt med blandede bilfl\u00e5der:<\/strong> <a href=\"https:\/\/www.charin.global\/media\/pages\/technology\/knowledge-base\/0c2cc2c8da-1747654352\/250508_whitepaper_megawatt_charging_system_2.0.pdf#page=15\" rel=\"nofollow\">CharIN-fagrapporten om megawattladesystem (MCS) 2.0 (s. 15 og 17)<\/a> anbefaler, at tunge lastbilers ladeindtag placeres p\u00e5 <strong>k\u00f8ret\u00f8jets venstre side<\/strong>bag den forreste aksel. De adspurgte producenter oplyste placeringer i en l\u00e6ngdeafstand p\u00e5 <strong>2.0 m til 4.8 m<\/strong> fra k\u00f8ret\u00f8jets front, og rapporten anbefaler en maksimal kabell\u00e6ngde p\u00e5 <strong>15 m<\/strong>. Kontroll\u00e9r den reelle r\u00e6kkevidde p\u00e5 stedet for den valgte stander og kabelf\u00f8ring. P\u00e5 elektriske pickupper, varevogne og \u00e6ldre CCS1\/CCS2-lastbiler er ladeindtagene b\u00e5de til venstre, h\u00f8jre, foran og bagp\u00e5.<\/li>\n    <li><strong>Kontroll\u00e9r r\u00e6kkevidden for et 5 m standardkabel p\u00e5 stedet:<\/strong> Mange h\u00f8jtydende DC-ladestandere leveres med et standardkabel p\u00e5 <strong>5 m (16.4 ft)<\/strong> . Om et 5 m kabel n\u00e5r en parkeret lastbil eller et vogntog, ogs\u00e5 ved U.S. Access Boards referenceafstand p\u00e5 5 ft, kan ikke afg\u00f8res af l\u00e6ngden alene. Kontroll\u00e9r <strong>tolerancen ved standsning, kabeludgangens sted og h\u00f8jde, ladeindtagets n\u00f8jagtige placering samt kabeloprullerens vandring eller svingarmens bev\u00e6gelse<\/strong>. Ved blandede fl\u00e5der med ladeindtag p\u00e5 begge sider b\u00f8r tosidede lade\u00f8er eller kabelf\u00f8ring over k\u00f8ret\u00f8jerne overvejes.<\/li>\n    <li><strong>Klarg\u00f8r kabelr\u00f8r til MCS:<\/strong> Kontroll\u00e9r reservekapacitet i h\u00f8jsp\u00e6ndingsr\u00f8r og fundamenter, n\u00e5r der graves til ladestandere p\u00e5 350\u2013500 kW med CCS2\/CCS1 langs godskorridorer. S\u00e5 kan fremtidig opgradering til <a href=\"https:\/\/www.evb.com\/da\/mcs-vs-ccs-for-electric-trucks-2026-engineering-roi-grid-reality\/\">megawattladesystemer (MCS sammenlignet med CCS)<\/a> udf\u00f8res uden at sk\u00e6re i f\u00e6rdige k\u00f8rearealer.<\/li>\n  <\/ol>\n\n  <h2 id=\"hardware-architecture-and-evb-selection\">5. Valg mellem opdelte og integrerede DC-ladere<\/h2>\n\n  <p>Sammenlign de opdelte EVB-systemer BSDC720 og BDCS, hvis flere pladser deler et ensretterskab uden for lade\u00f8en. Overvej EVB BDC240-D, hvis to gennemk\u00f8rselspladser ved siden af hinanden kan dele en lader p\u00e5 \u00f8en. De to stik deler en samlet effekt p\u00e5 240 kW. Mark\u00e9r begge k\u00f8ret\u00f8jers ladeindtag p\u00e5 planen, og kontroll\u00e9r r\u00e6kkevidden med begge k\u00f8ret\u00f8jer parkeret.<\/p>\n\n  <p class=\"evb-table-title\" id=\"tbl-evb-hardware-title\">Sammenligning af EVB DC-ladere til gennemk\u00f8rselsanl\u00e6g<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-evb-hardware-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">Model &amp; konfiguration<\/th>\n          <th scope=\"col\">Systemeffekt &amp; effekt pr. stik<\/th>\n          <th scope=\"col\">Udstyrsm\u00e5l &amp; kabell\u00e6ngde<\/th>\n          <th scope=\"col\">AC-indgang, standarder &amp; protokoller<\/th>\n          <th scope=\"col\">Egnede anl\u00e6g &amp; kontrolpunkter<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/da\/product-item\/720kw-liquid-cooling-dc-ev-charging-stations-with-independent-duct\/\">BSDC720-250D5<\/a><br>(720 kW opdelt DC-anl\u00e6g)<\/th>\n          <td>Systemet leverer op til <strong>720 kW<\/strong> samlet, med en spidseffekt p\u00e5 <strong>500 kW<\/strong> pr. terminal. Levering af 500 kW via \u00e9t stik kr\u00e6ver cirka 1,000 V ved k\u00f8ret\u00f8jet, 500 A ved stikket og tilstr\u00e6kkelig tildelt effekt p\u00e5 terminalen. Den <strong>v\u00e6skek\u00f8lede variant til 0\u2013500 A<\/strong> f\u00e5s kun til <strong>CCS2 \/ GB\/T<\/strong> . <strong>CCS1 \/ NACS<\/strong> support <strong>0\u2013250 A<\/strong> med luftk\u00f8lede kabler (150\u20131,000 V DC). CHAdeMO underst\u00f8tter 0\u2013150 A ved 150\u2013500 V DC. Enkelt- og dobbeltterminaler d\u00e6kker op til 10 stik pr. system. Kontroll\u00e9r, hvordan den valgte terminal fordeler effekten ved brug af begge stik.<\/td>\n          <td>Ladeterminal: <strong>600 &times; 230 &times; 1,700 mm<\/strong> (&le;110 kg). Ensretterskab: 1,700 &times; 1,000 &times; 2,150 mm (&le;1,100 kg). Standardkabel: <strong>5 m<\/strong>; IP55, IK10 (sk\u00e6rm IK08).<\/td>\n          <td><strong>380\u2013415 V AC<\/strong>, 3P+N+PE, 50\/60 Hz, m\u00e6rkeindgangsstr\u00f8m <strong>1,100 A<\/strong>; standarder: EN IEC 61851-1\/-23\/-24\/-21-2; OCPP 1.6J.<\/td>\n          <td><strong>Erhvervsanl\u00e6g med flere ladepladser og lastbilrastepladser.<\/strong> Angiv netsp\u00e6nding, k\u00f8ret\u00f8jssp\u00e6nding og stiktype for nordamerikanske anl\u00e6g. Sp\u00f8rg efter en passende model og dokumentation, hvis installationen kr\u00e6ver 480 V AC og UL-listning. Bed EVB bekr\u00e6fte CCS1\/NACS-str\u00f8mstyrke, effektfordeling og muligheder for l\u00e6ngere kabler eller kabelf\u00f8ring ovenfra.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/da\/product-item\/floor-mounted-split-dc-megawatt-charging-system\/\">BDCS500\u2013BDCS2000<\/a><br>(500 kW\u20132 MW opdelt megawatt-DC-ladesystem)<\/th>\n          <td><strong>500 \/ 1,000 \/ 1,500 \/ 2,000 kW<\/strong> modul\u00e6re ensretterskabe; enkelt <strong>MCS<\/strong> stik (0\u20131,250 V DC, <strong>0\u20131,500 A<\/strong> v\u00e6skek\u00f8let) eller dobbelt <strong>CCS2<\/strong> (150\u20131,000 V DC, <strong>0\u2013650 A<\/strong> v\u00e6skek\u00f8let pr. stik).<\/td>\n          <td>Modul\u00e6re ensretterskabe (&le;730 kg pr. 500 kW-blok, op til &times;4); ladeterminal &le;110 kg (bekr\u00e6ft fundamenttegningens n\u00f8jagtige B &times; D &times; H i projektmaterialet). Standardkabel: <strong>5 m<\/strong>; IP55, IK10 (sk\u00e6rm IK08).<\/td>\n          <td><strong>380\u2013415 V AC<\/strong>, 3P+N+PE, 50\/60 Hz (m\u00e6rkeindgangsstr\u00f8m 760\u20133,039 A); virkningsgrad &ge;97%; EN IEC 61851-1\/-23\/-24\/-21-2; OCPP 1.6J.<\/td>\n          <td><strong>EU\u2019s TEN-T-korridorer for tunge k\u00f8ret\u00f8jer, som er omfattet af AFIR, og megawattladeanl\u00e6g til lastbiler.<\/strong> Oplys EVB om transformatorens m\u00e6rkeeffekt, k\u00f8ret\u00f8jskrav og den planlagte kabelvej for at f\u00e5 bekr\u00e6ftet effektkonfiguration, muligheder for ISO 15118 og kabelr\u00e6kkevidde. Sp\u00f8rg ved et nordamerikansk projekt, om der findes en model til 480 V med den kr\u00e6vede UL-listning.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/da\/product-item\/floor-mounted-dc-2-guns-ev-dc-fast-charger\/\">BDC240-D<\/a><br>(240 kW gulvmonteret DC-lader med to stik)<\/th>\n          <td><strong>240 kW samlet<\/strong>, fordelt dynamisk n\u00e5r to k\u00f8ret\u00f8jer lader. CCS1, CCS2, GB\/T og NACS underst\u00f8tter 150\u20131,000 V DC og op til 250 A. CHAdeMO underst\u00f8tter 150\u2013500 V DC og op til 150 A. Effekten ved hvert k\u00f8ret\u00f8j afh\u00e6nger af sp\u00e6ndingen, den \u00f8nskede str\u00f8mstyrke og den effekt, som stikket har til r\u00e5dighed.<\/td>\n          <td>Skab: <strong>800 &times; 800 &times; 1,800 mm<\/strong> (&le;440 kg). Standardkabell\u00e6ngde: <strong>5 m<\/strong>. Kapslingsklasse: IP55.<\/td>\n          <td><strong>380\u2013415 V AC<\/strong>, trefaset med nulleder og beskyttelsesjord, 50\/60 Hz. M\u00e6rkeindgangsstr\u00f8m: <strong>365 A<\/strong>. IEC 61851-1, -23 og -24. OCPP 1.6J.<\/td>\n          <td><strong>To gennemk\u00f8rselspladser ved siden af hinanden, som deler \u00e9n lader.<\/strong> Afs\u00e6t plads til skabsd\u00f8re og pullerter. Oplys EVB om netsp\u00e6nding, n\u00f8dvendig godkendelse og stikkombination p\u00e5 et anl\u00e6g med 480 V, s\u00e5 EVB kan v\u00e6lge en passende konfiguration.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">Hent specifikationerne for <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2025\/12\/BENY-Datasheet%EF%BC%88Beny-720kW-Floor-Mounted-Split-DC-EV-Charger-Station%EF%BC%89-2025.12.25.pdf\">BSDC720-250D5 v20251225-01 (PDF-datablad)<\/a>, <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/04\/BENY-Datasheetof-Split-Megawatt-Power-DC-EV-Charger-500kW-to-2MW%EF%BC%88BDCS%EF%BC%892026.03.03.pdf\">BDCS500\u20132000 v20260310-01 (PDF-datablad)<\/a>, og <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet%EF%BC%88Beny-2-Guns-DC-EV-Charging-Station%EF%BC%892025.12.29.pdf#page=6\">BDC240-D (PDF, side 6)<\/a>. De to opdelte systemer og BDC240-D-konfigurationen i tabellen er beregnet til anl\u00e6g under 2,000 m og omgivelsestemperaturer fra &minus;30 til +50 &deg;C. F\u00e5 bekr\u00e6ftet UL-listning eller CE-dokumentation, muligheder for ISO 15118, kabell\u00e6ngde og fundamentsforankring i projekttilbuddet.<\/p>\n\n  <h2 id=\"rfq-and-design-verification-checklist\">6. Tjekliste for gennemk\u00f8rselsanl\u00e6g &amp; tilbudsanmodning<\/h2>\n\n  <div class=\"evb-checklist\">\n    <h3>Otte forhold at kontrollere f\u00f8r byggetilladelse &amp; indk\u00f8bsordrer<\/h3>\n    <ol>\n      <li><strong>Beregning med dimensionerende k\u00f8ret\u00f8j &amp; kontrol af k\u00f8rekurver:<\/strong> Dokument\u00e9r k\u00f8ret\u00f8jets n\u00f8jagtige l\u00e6ngde og stopmargener foran og bagved. Brug derefter AutoTURN eller lignende fra kantstenss\u00e6nkning til udk\u00f8rsel for at kontrollere sporafvigelse, bagendens udsving og fri afstand til overd\u00e6kningens s\u00f8jler.<\/li>\n      <li><strong>Antal gennemk\u00f8rselspladser ud fra k\u00f8beregning:<\/strong> Find antal baner ud fra spidsankomster for lastbiler og vogntog, ladetid og acceptabel ventetid. Med individuelle lige udk\u00f8rsler bliver et f\u00e6rdigladet k\u00f8ret\u00f8j aldrig blokeret af k\u00f8ret\u00f8jet foran.<\/li>\n      <li><strong>Separate kontroller af tilg\u00e6ngelighed:<\/strong> Kontroll\u00e9r p\u00e5 anl\u00e6g i USA pladsbredde (&ge;16 ft \/ 4,880 mm), niveaufri udformning eller kantstenss\u00e6nkning, fri gulvplads efter ADA &sect;305, adgangsretning, r\u00e6kkeviddedybde og -h\u00f8jde efter &sect;308 samt kabeltilslutning til et k\u00f8ret\u00f8j 5 ft (1,525 mm) v\u00e6k. F\u00f8lg nationale regler uden for USA.<\/li>\n      <li><strong>Koordin\u00e9r p\u00e5k\u00f8rselsbeskyttelse med adgang:<\/strong> Bekr\u00e6ft de lokale krav i IFC &sect;312.2 eller funktionskrav i &sect;312.3 med AHJ. Plac\u00e9r pullerterne i linje med standerens sider, eller brug godkendte barrierer uden at indskr\u00e6nke k\u00f8restolens frie plads.<\/li>\n      <li><strong>Lokale farezoner ved blandede br\u00e6ndstoffer:<\/strong> Gennemg\u00e5 de faktiske br\u00e6ndstoffer, p\u00e5fyldningsforbindelser, ventilation, anvendt forskriftsudgave (NFPA 30A \/ NEC Art. 514 \/ ATEX) og det farezonekort, AHJ har godkendt. B\u00e5de EVSE og hele kablets bev\u00e6gelsesomr\u00e5de skal v\u00e6re uden for klassificerede omr\u00e5der.<\/li>\n      <li><strong>Placering af effektskab uden for lade\u00f8en:<\/strong> Kontroll\u00e9r afstande ved ensretterskabets fundament (arbejdsplads efter NEC &sect;110.26 \/ IEC), plads til \u00e5ben d\u00f8r, p\u00e5k\u00f8rselsbeskyttelse og k\u00f8leluft uden for aktive lastbilbaner.<\/li>\n      <li><strong>Kontrol af faktisk kabelr\u00e6kkevidde:<\/strong> Kontroll\u00e9r med et standardkabel p\u00e5 <strong>5 m<\/strong> r\u00e6kkevidden i forhold til stopmargin, kabeludgangens h\u00f8jde, ladeindtagets koordinater og kabeloprullerens vandring. Angiv ellers l\u00e6ngere kabler eller kabelf\u00f8ring ovenfra i tilbudsanmodningen.<\/li>\n      <li><strong>Anl\u00e6ggets effekt og gr\u00e6nser for stik.<\/strong> Tilpas laderens AC-m\u00e6rkeindgangssp\u00e6nding og -str\u00f8m til den tilg\u00e6ngelige nettilslutning. Oplys EVB om BDC240-D-stikkombinationen og hver bils effektbehov, n\u00e5r begge pladser bruges. Reserv\u00e9r kabelr\u00f8r til senere udvidelse.<\/li>\n    <\/ol>\n  <\/div>\n\n  <div class=\"evb-callout\">\n    <h3>Planl\u00e6gger du en gennemk\u00f8rselsladeplads eller et ladedepot til el-lastbiler?<\/h3>\n    <p>Send anl\u00e6gsplan, k\u00f8ret\u00f8jstyper og tilg\u00e6ngelig nettilslutning til EVB\u2019s teknikere. De kan hj\u00e6lpe med at placere terminaler, kontrollere kabelr\u00e6kkevidde og tilpasse stikstr\u00f8mmen til k\u00f8ret\u00f8jerne. Oplys eventuelle regionale godkendelseskrav. Se EVB\u2019s <a href=\"https:\/\/www.evb.com\/da\/by-vehicle-type\/electric-truck-charging\/\">ladel\u00f8sninger til el-lastbiler<\/a> og <a href=\"https:\/\/www.evb.com\/da\/by-industry\/fleet-charging\/\">Opladningsl\u00f8sninger til elbilfl\u00e5der<\/a>, eller anmod om et projekttilbud.<\/p>\n    <a class=\"evb-cta-btn\" href=\"https:\/\/www.evb.com\/da\/ev-charger-customization\/\">Bed om tilbud p\u00e5 gennemk\u00f8rselslayout &amp; ladeudstyr<\/a>\n  <\/div>\n\n  <h2 id=\"frequently-asked-questions\">7. Ofte stillede sp\u00f8rgsm\u00e5l<\/h2>\n\n  <h3>Hvor bred b\u00f8r en gennemk\u00f8rselsladeplads til elk\u00f8ret\u00f8jer v\u00e6re?<\/h3>\n  <p>U.S. Access Board kr\u00e6ver ikke individuel afm\u00e6rkning af gennemk\u00f8rselsladepladser i USA. Anbefalingen er en bredde p\u00e5 mindst <strong>16 ft (4,880 mm)<\/strong> og et kabel, der kan n\u00e5 et k\u00f8ret\u00f8j parkeret <strong>5 ft (1,525 mm)<\/strong> fra ladestanderen. Uden for USA skal bredde og adgang f\u00f8lge nationale krav til tunge k\u00f8ret\u00f8jer og tilg\u00e6ngelighed.<\/p>\n\n  <h3>Hvordan beregner man l\u00e6ngden p\u00e5 en gennemk\u00f8rselsladeplads til en pickup med anh\u00e6nger eller et s\u00e6ttevognstog?<\/h3>\n  <p>Start med den n\u00f8jagtige k\u00f8ret\u00f8jsl\u00e6ngde og tilf\u00f8j s\u00e6rskilte margener foran og bagved. Et vogntog med pickup og anh\u00e6nger p\u00e5 50 ft plus 5 ft foran og 5 ft bagved giver for eksempel en <strong>60 ft (18.3 m)<\/strong> lang lige plads. Et EU-s\u00e6ttevognstog p\u00e5 16.5 m plus 2.5 m foran og bagved giver <strong>21.5 m<\/strong>; et amerikansk s\u00e6ttevognstog p\u00e5 73.5 ft plus 10 ft foran og bagved giver <strong>93.5 ft (28.5 m)<\/strong>. Kontroll\u00e9r derefter de lige ind- og udk\u00f8rselsstr\u00e6kninger og anh\u00e6ngerens sporafvigelse med en k\u00f8rekurvesimulering.<\/p>\n\n  <h3>Hvordan kombineres pullerter med tilg\u00e6ngelighedskrav p\u00e5 en gennemk\u00f8rsels\u00f8?<\/h3>\n  <p>Kontroll\u00e9r vandret p\u00e5k\u00f8rselsbeskyttelse og ADA kapitel 3 s\u00e6rskilt. Betonfyldte st\u00e5lpullerter ved standerens til- og frak\u00f8rselssider eller en AHJ-godkendt funktionsbarriere efter IFC &sect;312.3 beskytter skabet, samtidig med at det niveaufri gulvareal efter &sect;305, uhindret adgang og r\u00e6kkevidden efter &sect;308 bevares.<\/p>\n\n  <h3>Kan gennemk\u00f8rsels-hurtigladere st\u00e5 p\u00e5 samme grund som benzin- eller dieselstandere?<\/h3>\n  <p>Ja, hvis almindeligt EVSE uden eksplosionsbeskyttelse er placeret uden for klassificerede farezoner. Afstandskrav afh\u00e6nger af br\u00e6ndstoffet (benzin eller diesel) og lokalt g\u00e6ldende forskrifter (USA: NFPA 30A \/ NEC Art. 514; Europa: ATEX-direktiv 1999\/92\/EC og nationale regler). Kontroll\u00e9r kabinet og hele kabelf\u00f8ringen efter grundens AHJ-godkendte farezonekort.<\/p>\n\n  <h3>Hvorfor sammenligner mange gennemk\u00f8rselsanl\u00e6g opdelte DC-ladere med integrerede systemer?<\/h3>\n  <p>Med BSDC720 kan det <strong>1,700 &times; 1,000 &times; 2,150 mm<\/strong> store ensretterskab placeres p\u00e5 et separat fundament. S\u00e5 sidder kun den kompakte <strong>600 &times; 230 &times; 1,700 mm<\/strong> store ladeterminal p\u00e5 \u00f8en ved k\u00f8ret\u00f8jet. Sammenlign \u00f8ens bredde, serviceplads, p\u00e5k\u00f8rselsbeskyttelse og levetidsomkostninger med et integreret anl\u00e6g p\u00e5 tegningerne.<\/p>\n\n  <h3>Er et 5 m langt ladekabel tilstr\u00e6kkeligt til en gennemk\u00f8rselsladeplads?<\/h3>\n  <p>Afg\u00f8r f\u00f8rst geometrisk, om 5 m (16.4 ft) r\u00e6kker. Kontroll\u00e9r stopafvigelse, kabeludgangens h\u00f8jde, ladeindtagets placering og oprullerens vandring ved den n\u00f8dvendige sideafstand mellem k\u00f8ret\u00f8j og stander (f.eks. 5 ft efter U.S. Access Boards vejledning). Angiv tosidede lade\u00f8er, l\u00e6ngere kabler eller kabelf\u00f8ring ovenfra, hvis ladeindtagene kr\u00e6ver ekstra r\u00e6kkevidde.<\/p>\n\n  <h2 id=\"references\">8. V\u00e6sentlige standarder og tekniske referencer<\/h2>\n  <ul>\n    <li><a href=\"https:\/\/www.access-board.gov\/tad\/ev\/#pull-through-ev-charging-stations-design\" rel=\"nofollow\">U.S. Access Board \u2014 anbefalinger til tilg\u00e6ngelige ladestationer til elk\u00f8ret\u00f8jer (gennemk\u00f8rselsladestationer)<\/a>: afm\u00e6rkning, &ge;16 ft (4,880 mm) ladepladsbredde og 5 ft (1,525 mm) r\u00e6kkevidde for tilslutningskabel (tilg\u00e5et 24. november 2026).<\/li>\n    <li><a href=\"https:\/\/www.access-board.gov\/ada\/chapter\/ch03\/#308-reach-ranges\" rel=\"nofollow\">U.S. Access Board \u2014 ADA-standardernes kapitel 3 (&sect;305 frit gulv- eller terr\u00e6nareal &amp; &sect;308 r\u00e6kkevidde)<\/a>: niveaufrit areal, forl\u00e6ns eller parallel adgang, forhindringsdybde og r\u00e6kkevidde for betjeningsdele (tilg\u00e5et 24. november 2026).<\/li>\n    <li><a href=\"https:\/\/ops.fhwa.dot.gov\/freight\/publications\/size_regs_final_rpt\/index.htm\" rel=\"nofollow\">USA\u2019s f\u00f8derale vejmyndighed (FHWA) \u2014 program for erhvervsk\u00f8ret\u00f8jers dimensioner og v\u00e6gt<\/a> &amp; <a href=\"https:\/\/mutcd.fhwa.dot.gov\/\" rel=\"nofollow\">FHWA\u2019s h\u00e5ndbog i ensartet trafikskiltning og trafikregulering (MUTCD)<\/a>: f\u00f8derale m\u00e5lgr\u00e6nser for erhvervsk\u00f8ret\u00f8jer og principper for trafikskiltning (tilg\u00e5et 24. november 2026).<\/li>\n    <li><a href=\"https:\/\/driveelectric.gov\/\" rel=\"nofollow\">F\u00e6lles amerikansk kontor for energi og transport \u2014 vejledning om offentlig &amp; erhvervsm\u00e6ssig opladning af elk\u00f8ret\u00f8jer<\/a>: ressourcer om anl\u00e6gsindretning, korridorplanl\u00e6gning og tilg\u00e6ngelighed (tilg\u00e5et 24. november 2026).<\/li>\n    <li><a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/1996\/53\/oj\/eng\" rel=\"nofollow\">Den Europ\u00e6iske Union \u2014 R\u00e5dets direktiv 96\/53\/EC (bilag I)<\/a>: h\u00f8jeste tilladte k\u00f8ret\u00f8jsm\u00e5l (16.50 m s\u00e6ttevognstog, 18.75 m vogntog, 4.00 m h\u00f8jde) og k\u00f8ret\u00f8jets drejeomr\u00e5de (12.50 m ydre radius \/ 5.30 m indre radius; tilg\u00e5et 24. november 2026).<\/li>\n    <li><a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2023\/1804\/oj\" rel=\"nofollow\">Den Europ\u00e6iske Union \u2014 forordning (EU) 2023\/1804 (AFIR), artikel 4<\/a>: bindende milep\u00e6le for ladeparker til tunge k\u00f8ret\u00f8jer p\u00e5 TEN-T-hovednettet og det samlede net i 2025, 2027 og 2030 (tilg\u00e5et 24. november 2026).<\/li>\n    <li><a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/1999\/92\/oj\/eng\" rel=\"nofollow\">Den Europ\u00e6iske Union \u2014 direktiv 1999\/92\/EC (ATEX-arbejdspladsdirektivet)<\/a>: mindstekrav til klassificering af omr\u00e5der med eksplosiv atmosf\u00e6re p\u00e5 anl\u00e6g med blandede br\u00e6ndstoffer (tilg\u00e5et 24. november 2026).<\/li>\n    <li><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" rel=\"nofollow\">NFPA 70 (amerikanske elinstallationsregler \u2014 artikel 110.26, 514 &amp; 625)<\/a> &amp; <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-30a-standard-development\/30a\" rel=\"nofollow\">NFPA 30A (forskrift for anl\u00e6g til br\u00e6ndstofp\u00e5fyldning og reparationsv\u00e6rksteder)<\/a>: effektoverf\u00f8rende kredsl\u00f8b for elk\u00f8ret\u00f8jer, frirum ved elarbejde og klassificering af br\u00e6ndstofomr\u00e5der (tilg\u00e5et 24. november 2026).<\/li>\n    <li>International Code Council (ICC) \u2014 international brandforskrift (IFC), afsnit 312 (p\u00e5k\u00f8rselsbeskyttelse): foreskrevne pullerter efter &sect;312.2 og funktionsbaserede barrierer efter &sect;312.3 (bekr\u00e6ft den lokale udgave med AHJ).<\/li>\n    <li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/33644\" rel=\"nofollow\">IEC 61851-1:2017<\/a> (Konduktivt ladesystem til elektriske k\u00f8ret\u00f8jer, del 1) &amp; <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">IEC 60364-7-722:2018<\/a> (Lavsp\u00e6ndingsinstallationer \u2014 forsyning til elektriske k\u00f8ret\u00f8jer; tilg\u00e5et 24. november 2026).<\/li>\n    <li><a href=\"https:\/\/www.charin.global\/media\/pages\/technology\/knowledge-base\/0c2cc2c8da-1747654352\/250508_whitepaper_megawatt_charging_system_2.0.pdf#page=15\" rel=\"nofollow\">CharIN \u2014 fagrapport om megawattladesystem (MCS) 2.0 (s. 15 &amp; 17)<\/a>: anbefalet placering af tunge lastbilers ladeindtag til venstre, producenternes angivne afstand fra front til ladeindtag p\u00e5 2.0\u20134.8 m og bem\u00e6rkning om kabel p\u00e5 15 m (tilg\u00e5et 24. november 2026).<\/li>\n    <li>EVB-produktspecifikationer: <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2025\/12\/BENY-Datasheet%EF%BC%88Beny-720kW-Floor-Mounted-Split-DC-EV-Charger-Station%EF%BC%89-2025.12.25.pdf\">BSDC720-250D5 720 kW opdelt DC-hurtigladestation (v20251225-01)<\/a> og <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/04\/BENY-Datasheetof-Split-Megawatt-Power-DC-EV-Charger-500kW-to-2MW%EF%BC%88BDCS%EF%BC%892026.03.03.pdf\">BDCS500\u20132000 opdelt megawatt-DC-lader til elk\u00f8ret\u00f8jer (v20260310-01)<\/a> (tilg\u00e5et 24. november 2026).<\/li>\n    <li><a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet%EF%BC%88Beny-2-Guns-DC-EV-Charging-Station%EF%BC%892025.12.29.pdf#page=6\">EVB BDC240-D DC-lader med to stik, modelspecifikationer (version 20251229-01, PDF side 6)<\/a> (tilg\u00e5et 25. november 2026).<\/li>\n  <\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>EVB.COM &middot; Author: EVB Charging Solutions Team &middot; Updated November 2026 &middot; 15-minute read &middot; Pull-Through EV Charging &middot; Commercial DC Fast Charging &middot; Electric Trucks Pull-through EV charging station design lets electric trucks and towing rigs drive straight in and straight out without unhitching or reversing. Size each straight bay from your actual design-vehicle [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":44856,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[26],"tags":[214,172,487,236],"class_list":["post-44861","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-commercial-ev-charging","tag-electric-truck-charging","tag-pull-through-ev-charging","tag-split-dc-charger"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Pull-Through EV Charging Station Design for Trucks | EVB<\/title>\n<meta name=\"description\" content=\"Plan pull-through EV charging stations for trucks and trailers, check bay dimensions and clearances, and compare split and all-in-one DC fast chargers.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.evb.com\/da\/pull-through-ev-charging-station-design\/\" \/>\n<meta property=\"og:locale\" content=\"da_DK\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pull-Through EV Charging Station Design for Trucks | EVB\" \/>\n<meta property=\"og:description\" content=\"Plan pull-through EV charging stations for trucks and trailers, check bay dimensions and clearances, and compare split and all-in-one DC fast chargers.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.evb.com\/da\/pull-through-ev-charging-station-design\/\" \/>\n<meta property=\"og:site_name\" content=\"EVB\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-25T05:05:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-25T05:05:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"EVB Editorial Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Skrevet af\" \/>\n\t<meta name=\"twitter:data1\" content=\"EVB Editorial Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Estimeret l\u00e6setid\" \/>\n\t<meta name=\"twitter:data2\" content=\"19 minutter\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/\"},\"author\":{\"name\":\"EVB Editorial Team\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/person\\\/fe8f0137976034abdfd2ae4f8c5682d0\"},\"headline\":\"Pull-Through EV Charging Station Design: Dimensions, Layout &amp; Split-DC Hardware for Trucks &amp; Towing\",\"datePublished\":\"2026-11-25T05:05:41+00:00\",\"dateModified\":\"2026-11-25T05:05:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/\"},\"wordCount\":3924,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/evb-pull-through-ev-charging-station-design-cover.webp\",\"keywords\":[\"commercial EV charging\",\"electric truck charging\",\"Pull-Through EV Charging\",\"split DC charger\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"da-DK\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/\",\"url\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/\",\"name\":\"Pull-Through EV Charging Station Design for Trucks | EVB\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/evb-pull-through-ev-charging-station-design-cover.webp\",\"datePublished\":\"2026-11-25T05:05:41+00:00\",\"dateModified\":\"2026-11-25T05:05:50+00:00\",\"description\":\"Plan pull-through EV charging stations for trucks and trailers, check bay dimensions and clearances, and compare split and all-in-one DC fast chargers.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#breadcrumb\"},\"inLanguage\":\"da-DK\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/evb-pull-through-ev-charging-station-design-cover.webp\",\"contentUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/evb-pull-through-ev-charging-station-design-cover.webp\",\"width\":1600,\"height\":900,\"caption\":\"evb pull through ev charging station design cover\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.evb.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pull-Through EV Charging Station Design: Dimensions, Layout &amp; Split-DC Hardware for Trucks &amp; Towing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#website\",\"url\":\"https:\\\/\\\/www.evb.com\\\/\",\"name\":\"EVB\",\"description\":\"Smart EV Charging &amp; Energy Storage Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.evb.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"da-DK\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\",\"name\":\"EVB\",\"url\":\"https:\\\/\\\/www.evb.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/evb-3.png\",\"contentUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/evb-3.png\",\"width\":605,\"height\":626,\"caption\":\"EVB\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/person\\\/fe8f0137976034abdfd2ae4f8c5682d0\",\"name\":\"EVB Editorial Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"da-DK\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"caption\":\"EVB Editorial Team\"},\"description\":\"The EVB Editorial Team creates expert content on EV charging infrastructure, commercial charging solutions, energy storage integration, and global charging projects, with input from EVB product and engineering specialists.\",\"sameAs\":[\"https:\\\/\\\/www.evb.com\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Planl\u00e6gning af gennemk\u00f8rselsladestationer til el-lastbiler | EVB","description":"Planl\u00e6g gennemk\u00f8rselsladestationer til lastbiler og vogntog, kontroll\u00e9r ladepladsernes m\u00e5l og frirum, og sammenlign opdelte og integrerede DC-hurtigladere.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.evb.com\/da\/pull-through-ev-charging-station-design\/","og_locale":"da_DK","og_type":"article","og_title":"Pull-Through EV Charging Station Design for Trucks | EVB","og_description":"Plan pull-through EV charging stations for trucks and trailers, check bay dimensions and clearances, and compare split and all-in-one DC fast chargers.","og_url":"https:\/\/www.evb.com\/da\/pull-through-ev-charging-station-design\/","og_site_name":"EVB","article_published_time":"2026-11-25T05:05:41+00:00","article_modified_time":"2026-11-25T05:05:50+00:00","og_image":[{"width":1600,"height":900,"url":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp","type":"image\/webp"}],"author":"EVB Editorial Team","twitter_card":"summary_large_image","twitter_misc":{"Skrevet af":"EVB Editorial Team","Estimeret l\u00e6setid":"19 minutter"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#article","isPartOf":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/"},"author":{"name":"EVB Editorial Team","@id":"https:\/\/www.evb.com\/#\/schema\/person\/fe8f0137976034abdfd2ae4f8c5682d0"},"headline":"Pull-Through EV Charging Station Design: Dimensions, Layout &amp; Split-DC Hardware for Trucks &amp; Towing","datePublished":"2026-11-25T05:05:41+00:00","dateModified":"2026-11-25T05:05:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/"},"wordCount":3924,"commentCount":0,"publisher":{"@id":"https:\/\/www.evb.com\/#organization"},"image":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#primaryimage"},"thumbnailUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp","keywords":["commercial EV charging","electric truck charging","Pull-Through EV Charging","split DC charger"],"articleSection":["Blog"],"inLanguage":"da-DK","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/","url":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/","name":"Planl\u00e6gning af gennemk\u00f8rselsladestationer til el-lastbiler | EVB","isPartOf":{"@id":"https:\/\/www.evb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#primaryimage"},"image":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#primaryimage"},"thumbnailUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp","datePublished":"2026-11-25T05:05:41+00:00","dateModified":"2026-11-25T05:05:50+00:00","description":"Planl\u00e6g gennemk\u00f8rselsladestationer til lastbiler og vogntog, kontroll\u00e9r ladepladsernes m\u00e5l og frirum, og sammenlign opdelte og integrerede DC-hurtigladere.","breadcrumb":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#breadcrumb"},"inLanguage":"da-DK","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/"]}]},{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#primaryimage","url":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp","contentUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp","width":1600,"height":900,"caption":"evb pull through ev charging station design cover"},{"@type":"BreadcrumbList","@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.evb.com\/"},{"@type":"ListItem","position":2,"name":"Pull-Through EV Charging Station Design: Dimensions, Layout &amp; Split-DC Hardware for Trucks &amp; Towing"}]},{"@type":"WebSite","@id":"https:\/\/www.evb.com\/#website","url":"https:\/\/www.evb.com\/","name":"EVB","description":"Smarte ladel\u00f8sninger til elbiler og energilagring","publisher":{"@id":"https:\/\/www.evb.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.evb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"da-DK"},{"@type":"Organization","@id":"https:\/\/www.evb.com\/#organization","name":"EVB","url":"https:\/\/www.evb.com\/","logo":{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/www.evb.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.evb.com\/wp-content\/uploads\/2021\/03\/evb-3.png","contentUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2021\/03\/evb-3.png","width":605,"height":626,"caption":"EVB"},"image":{"@id":"https:\/\/www.evb.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.evb.com\/#\/schema\/person\/fe8f0137976034abdfd2ae4f8c5682d0","name":"EVB-redaktionen","image":{"@type":"ImageObject","inLanguage":"da-DK","@id":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","caption":"EVB Editorial Team"},"description":"EVB-redaktionen udarbejder fagligt indhold om ladeinfrastruktur til elbiler, kommercielle ladel\u00f8sninger, integration af energilagring og ladeprojekter verden over med input fra EVB's produktspecialister og ingeni\u00f8rer.","sameAs":["https:\/\/www.evb.com\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.evb.com\/da\/wp-json\/wp\/v2\/posts\/44861","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.evb.com\/da\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.evb.com\/da\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.evb.com\/da\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.evb.com\/da\/wp-json\/wp\/v2\/comments?post=44861"}],"version-history":[{"count":1,"href":"https:\/\/www.evb.com\/da\/wp-json\/wp\/v2\/posts\/44861\/revisions"}],"predecessor-version":[{"id":44869,"href":"https:\/\/www.evb.com\/da\/wp-json\/wp\/v2\/posts\/44861\/revisions\/44869"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.evb.com\/da\/wp-json\/wp\/v2\/media\/44856"}],"wp:attachment":[{"href":"https:\/\/www.evb.com\/da\/wp-json\/wp\/v2\/media?parent=44861"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.evb.com\/da\/wp-json\/wp\/v2\/categories?post=44861"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.evb.com\/da\/wp-json\/wp\/v2\/tags?post=44861"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}