{"id":44823,"date":"2026-11-21T16:49:33","date_gmt":"2026-11-21T08:49:33","guid":{"rendered":"https:\/\/www.evb.com\/?p=44823"},"modified":"2026-11-21T16:49:45","modified_gmt":"2026-11-21T08:49:45","slug":"mode-2-vs-mode-3-ev-charging","status":"publish","type":"post","link":"https:\/\/www.evb.com\/fr\/mode-2-vs-mode-3-ev-charging\/","title":{"rendered":"Recharge des v\u00e9hicules \u00e9lectriques en mode 2 ou en mode 3\u00a0: quand utiliser un chargeur portable ou une borne de recharge murale\u00a0?"},"content":{"rendered":"<style>\n.evb-modes-article{font-family:inherit;color:#1f1f1f;font-size:17px;line-height:1.8;overflow-wrap:break-word}\n.evb-modes-article h2,.evb-modes-article h3{color:#0b2239;line-height:1.3}\n.evb-modes-article h2{font-size:30px;font-weight:800;margin:44px 0 14px}\n.evb-modes-article h3{font-size:22px;font-weight:700;margin:26px 0 10px}\n.evb-modes-article p{margin:0 0 18px;color:#3f4852}\n.evb-modes-article a{color:#185fa5;text-decoration:underline;text-underline-offset:2px}\n.evb-modes-article a:focus-visible,.evb-modes-article .evb-table-wrap:focus-visible{outline:2px solid #185fa5;outline-offset:3px}\n.evb-modes-article .evb-eeat-line{margin:0 0 26px;color:#667584;font-size:15px;line-height:1.7}\n.evb-modes-article .evb-article-intro{border-left:4px solid #185fa5;background:#f4f8fc;padding:16px 20px;border-radius:0 8px 8px 0;margin:0 0 24px;font-size:17.5px;line-height:1.72;color:#172b3e}\n.evb-modes-article .evb-example-box{background:#f0f7fb;border:1px solid #cce0ee;border-radius:8px;padding:15px 18px;margin:0 0 22px;font-size:16px;color:#163146}\n.evb-modes-article ul,.evb-modes-article ol{margin:0 0 18px 22px;padding:0}\n.evb-modes-article li{margin:0 0 9px;color:#3f4852}\n.evb-modes-article .evb-table-title{margin:20px 0 8px;color:#0b2239;font-weight:700;font-size:15.5px;line-height:1.45}\n.evb-modes-article .evb-table-wrap{max-width:100%;overflow-x:auto;margin:0 0 12px;-webkit-overflow-scrolling:touch}\n.evb-modes-article .evb-table{width:100%;min-width:600px;border-collapse:collapse;font-size:15px}\n.evb-modes-article .evb-table th,.evb-modes-article .evb-table td{border:1px solid #dfe6ed;padding:11px 13px;text-align:left;vertical-align:top}\n.evb-modes-article .evb-table thead th{background:#0b2239;color:#fff;font-size:13.5px;letter-spacing:.02em}\n.evb-modes-article .evb-table tbody th{background:#f7fafe;color:#0b2239;font-weight:700}\n.evb-modes-article .evb-table tbody tr:nth-child(even) td{background:#fafcfe}\n.evb-modes-article .evb-table-note{font-size:13px;color:#526171;margin:0 0 24px}\n.evb-modes-article .evb-checklist{background:#f7f9fc;border:1px solid #d9e3ee;border-radius:8px;padding:18px 22px;margin:22px 0 26px}\n.evb-modes-article .evb-checklist h3,.evb-modes-article .evb-callout h3{margin-top:0}\n.evb-modes-article .evb-checklist>:last-child,.evb-modes-article .evb-callout>:last-child{margin-bottom:0}\n.evb-modes-article .evb-callout{background:#0b2239;color:#fff;border-radius:10px;padding:24px 26px;margin:32px 0}\n.evb-modes-article .evb-callout h3,.evb-modes-article .evb-callout p{color:#f1f6fb}\n.evb-modes-article .evb-callout a{color:#9fd4ff;font-weight:600}\n.evb-modes-article .evb-cta-btn{display:inline-block;margin-top:8px;background:#185fa5;color:#fff!important;text-decoration:none!important;padding:11px 22px;border-radius:7px;font-weight:700}\n.evb-modes-article .evb-cta-btn:hover{background:#124c85}\n.evb-modes-article .evb-article-figure{max-width:920px;margin:24px 0 28px}\n.evb-modes-article .evb-article-figure a{display:block}\n.evb-modes-article .evb-article-figure img{display:block;width:100%;height:auto;border-radius:10px;border:1px solid #dce5ee}\n.evb-modes-article figcaption{margin-top:9px;color:#526171;font-size:.88em;line-height:1.55}\n@media(max-width:768px){\n  .evb-modes-article{font-size:16px}\n  .evb-modes-article h2{font-size:24px;margin:34px 0 12px}\n  .evb-modes-article h3{font-size:19px}\n}\n<\/style>\n<div class=\"evb-article-wrap evb-modes-article\" lang=\"en\">\n  <div class=\"evb-eeat-line\">EVB.COM \u00b7 Auteur\u00a0: \u00c9quipe Solutions de recharge EVB \u00b7 Mise \u00e0 jour\u00a0: novembre\u00a02026 \u00b7 Temps de lecture\u00a0: 18\u00a0minutes \u00b7 Modes de recharge pour v\u00e9hicules \u00e9lectriques \u00b7 IEC\u00a061851 \u00b7 Recharge CA et CC<\/div>\n\n  <p class=\"evb-article-intro\"><strong>Les modes 2 et 3 permettent tous deux de recharger un v\u00e9hicule \u00e9lectrique avec du courant alternatif.<\/strong> Sur un c\u00e2ble de recharge portable de type 2, le petit bo\u00eetier situ\u00e9 entre la prise murale et le v\u00e9hicule est appel\u00e9 dispositif de contr\u00f4le et de protection int\u00e9gr\u00e9 au c\u00e2ble (IC-CPD). Il attend que le v\u00e9hicule soit pr\u00eat avant de mettre le courant. S&#039;il d\u00e9tecte un courant de fuite excessif pendant la charge, il coupe l&#039;alimentation. Une borne de recharge de type 3 g\u00e8re la charge \u00e0 la station et utilise un circuit d&#039;alimentation d\u00e9di\u00e9. Le mode 2 est pratique pour des recharges occasionnelles sur une prise adapt\u00e9e. Pour une recharge quotidienne \u00e0 un emplacement fixe, privil\u00e9giez le mode 3.<\/p>\n\n  <p>Avant de comparer les normes, les acheteurs et les planificateurs de sites choisissent g\u00e9n\u00e9ralement parmi trois configurations mat\u00e9rielles de climatisation pratiques\u00a0:<\/p>\n  <ul>\n    <li><strong>C\u00e2ble portable Mode 2.<\/strong> Il se branche sur une prise domestique, une prise pour v\u00e9hicule \u00e9lectrique ou une prise industrielle adapt\u00e9e. Conform\u00e9ment aux normes IEC 61851-1 et IEC 62752, la limite du mode 2 est de 32 A. La prise, le circuit et le c\u00e2ble peuvent chacun imposer une limite inf\u00e9rieure.<\/li>\n    <li><strong>Mode 3 avec une prise et un c\u00e2ble s\u00e9par\u00e9 (Cas B).<\/strong> Utilisez un c\u00e2ble compatible, par exemple celui que vous avez dans votre voiture. Branchez une extr\u00e9mit\u00e9 \u00e0 la prise de la borne (par exemple, une prise de type 2) et l&#039;autre \u00e0 la voiture. Une fois la charge termin\u00e9e, d\u00e9branchez les deux extr\u00e9mit\u00e9s et emportez le c\u00e2ble avec vous.<\/li>\n    <li><strong>Mode 3 avec un c\u00e2ble reli\u00e9 \u00e0 la station (Cas C).<\/strong> Saisissez le connecteur du c\u00e2ble de la station et branchez-le \u00e0 la voiture. Une fois termin\u00e9, d\u00e9branchez-le de la voiture et remettez-le dans son support. Le c\u00e2ble reste avec la station.<\/li>\n  <\/ul>\n\n  <div class=\"evb-example-box\"><strong>Exemple de dimensionnement rapide \u2014 V\u00e9rifiez les quatre plafonds ensemble\u00a0:<\/strong> La vitesse de charge CA r\u00e9elle est limit\u00e9e par la limite la plus basse parmi les <em>site d&#039;approvisionnement<\/em>, <em>chargeur<\/em>, <em>c\u00e2ble<\/em>, et <em>chargeur embarqu\u00e9 du v\u00e9hicule (OBC)<\/em>Par exemple, si une voiture accepte au maximum <strong>11 kW<\/strong> courant alternatif triphas\u00e9 et se branche sur un <strong>22 kW<\/strong> Bo\u00eetier mural (avec alimentation \u00e9lectrique et capacit\u00e9 de c\u00e2ble ad\u00e9quates), le v\u00e9hicule consomme toujours au maximum environ <strong>11 kW<\/strong>. Remplacement <strong>22 kWh<\/strong> L&#039;\u00e9nergie n\u00e9cessaire pour conduire quotidiennement prend environ <strong>9,6 heures<\/strong> sur un circuit de mode 2 v\u00e9rifi\u00e9 pour <strong>230 V, 10 A (2,3 kW)<\/strong> charge continue, contre environ <strong>2 heures<\/strong> en mode 3 \u00e0 <strong>11 kW<\/strong> (les deux en ignorant les pertes de conversion) \u2014 ce qui rend le mode 3 AC suffisant pour une utilisation nocturne ou au bureau sans avoir besoin d&#039;une charge rapide en courant continu.<\/div>\n\n  <p>EVB <a href=\"https:\/\/www.evb.com\/fr\/cables-de-charge-pour-vehicules-electriques\/\">Guide des c\u00e2bles de recharge pour v\u00e9hicules \u00e9lectriques<\/a> il d\u00e9crit d\u00e9j\u00e0 en d\u00e9tail les quatre modes de charge, tandis que <a href=\"https:\/\/www.evb.com\/fr\/chargeur-de-vehicule-electrique-avec-ou-sans-fil\/\">Bornes de recharge pour v\u00e9hicules \u00e9lectriques avec ou sans fil<\/a> compare le cas C au cas B et <a href=\"https:\/\/www.evb.com\/fr\/niveaux-de-charge-des-vehicules-electriques\/\">Niveaux de charge des v\u00e9hicules \u00e9lectriques<\/a> Ce guide couvre les niveaux nord-am\u00e9ricains. Il se concentre sur <strong>s\u00e9lection du champ entre le mode 2 et le mode 3<\/strong>, exact <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">CEI 60364-7-722:2018<\/a> et les limites de conformit\u00e9 AFIR de l&#039;UE, ainsi que les configurations des chargeurs EVB.<\/p>\n\n  <h2 id=\"when-to-choose-mode-2-mode-3-or-mode-4\">1. Matrice de s\u00e9lection des champs\u00a0: mode 2 vs mode 3 (quand utiliser chaque mode)<\/h2>\n\n  <p>Commencez par trois entr\u00e9es de site\u00a0:<strong>Combien de kWh par jour les v\u00e9hicules doivent-ils recharger ?<\/strong>, <strong>combien de temps ils restent stationn\u00e9s<\/strong>, et <strong>v\u00e9rifier si la prise ou le tableau de distribution est compatible avec une charge continue de v\u00e9hicule \u00e9lectrique<\/strong>:<\/p>\n\n  <figure class=\"evb-article-figure\">\n    <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/iec-61851-charging-modes-1-2-3-4-architecture.webp\" target=\"_blank\" rel=\"noopener\" title=\"Sch\u00e9ma du circuit de charge CA IEC 61851-1 en mode 2 et en mode 3 (pleine r\u00e9solution)\">\n      <img src=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/iec-61851-charging-modes-1-2-3-4-architecture.webp\" alt=\"Sch\u00e9ma ind\u00e9pendant de toute langue comparant le mode 2 de la norme IEC 61851-1 (prise vers c\u00e2ble IC-CPD vers chargeur embarqu\u00e9 de v\u00e9hicule \u00e9lectrique, jusqu&#039;\u00e0 32 A) et le mode 3 (circuit prot\u00e9g\u00e9 IEC 60364-7-722 vers borne de recharge CA fixe vers chargeur embarqu\u00e9 de v\u00e9hicule \u00e9lectrique, g\u00e9n\u00e9ralement de 3,7 \u00e0 22 kW), avec les ic\u00f4nes des cas de connexion B et C ci-dessous.\" width=\"920\" height=\"500\" loading=\"lazy\" decoding=\"async\" \/>\n    <\/a>\n    <figcaption>Comparaison des modes de charge CA 2 et 3 selon la norme IEC 61851-1:2017. Le mode 2 int\u00e8gre la commande pilote, la protection contre les fuites de courant et la commutation par relais dans un dispositif de protection contre les surintensit\u00e9s (IC-CPD) portable conforme \u00e0 la norme IEC 62752 (\u2264 32 A max. \u00e0 \u2264 250 V monophas\u00e9 ou \u2264 480 V triphas\u00e9, sous r\u00e9serve des limites de la prise\u00a0; la norme IEC 62752:2024 exige la d\u00e9tection de temp\u00e9rature sur les parties conductrices des prises domestiques). Le mode 3 d\u00e9place la commande et la commutation par contacteur vers une borne de recharge CA fixe sur un circuit prot\u00e9g\u00e9 conforme \u00e0 la norme IEC 60364-7-722 (g\u00e9n\u00e9ralement de 3,7 \u00e0 22 kW \u00e0 16 A\/32 A\u00a0; environ 43,5 kW sur certaines configurations triphas\u00e9es 400 V 63 A\u00a0; la gestion de la charge, le syst\u00e8me OCPP et les compteurs MID sont des options disponibles selon le mod\u00e8le). Les ic\u00f4nes du bas illustrent le cas B (c\u00e2ble d\u00e9tachable) et le cas C (chargeur filaire). Appuyez ou cliquez pour afficher la r\u00e9solution maximale.<\/figcaption>\n  <\/figure>\n\n  <p class=\"evb-table-title\" id=\"tbl-selection-title\">Matrice mondiale de s\u00e9lection des modes de recharge pour v\u00e9hicules \u00e9lectriques par site et conditions de fonctionnement<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-selection-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">Sc\u00e9nario de site et d&#039;exploitation<\/th>\n          <th scope=\"col\">Mode de d\u00e9marrage recommand\u00e9<\/th>\n          <th scope=\"col\">Contr\u00f4les critiques d&#039;ing\u00e9nierie et de conformit\u00e9<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\">Sauvegarde en cas de voyage, compl\u00e9ment pour visiteurs ou location temporaire sans autorisation d&#039;installation fixe<\/th>\n          <td><strong>Mode 2<\/strong> (Dispositif de protection contre les surtensions (IC-CPD) portable sur prise domestique ou pour v\u00e9hicule \u00e9lectrique)<\/td>\n          <td>V\u00e9rifiez la conformit\u00e9 \u00e0 la norme IEC 62752 (v\u00e9rifiez les sous-clauses 8.3.1 et 9.36 de l&#039;\u00e9dition 2.0 de 2024 concernant la d\u00e9tection de temp\u00e9rature sur les parties conductrices de courant des prises domestiques), distinguez les prises standard des prises homologu\u00e9es pour v\u00e9hicules \u00e9lectriques, limitez le courant continu en cons\u00e9quence et n&#039;utilisez jamais de rallonges.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Atelier, garage rural ou d\u00e9p\u00f4t temporaire avec prise CEE industrielle certifi\u00e9e (16 A \/ 32 A)<\/th>\n          <td><strong>Mode 2 (CEE)<\/strong> ou passer \u00e0 <strong>Mode 3<\/strong><\/td>\n          <td>V\u00e9rifiez le circuit IEC 60364-7-722 d\u00e9di\u00e9, la protection contre les surintensit\u00e9s en amont et la protection RCD de 30 mA, la capacit\u00e9 nominale continue de la prise CEE et si les r\u00e8gles locales exigent une station fixe de mode 3 pour la recharge permanente sur le lieu de travail.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Recharge r\u00e9sidentielle quotidienne (monophas\u00e9e 7,4 kW ou triphas\u00e9e 11\u201322 kW)<\/th>\n          <td><strong>Mode 3<\/strong> (bo\u00eetier mural fixe, cas B ou cas C)<\/td>\n          <td>Circuit d\u00e9di\u00e9 IEC 60364-7-722, ad\u00e9quation CEM classe B pour les r\u00e9seaux r\u00e9sidentiels, coordination RCD + d\u00e9faut CC v\u00e9rifi\u00e9e, conformit\u00e9 nationale de mise \u00e0 la terre et \u00e9quilibrage de charge dynamique (DLB) en option lorsque l&#039;alimentation principale est limit\u00e9e.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Parking \u00e0 plusieurs baies pour lieux de travail, h\u00f4tels, immeubles d&#039;appartements ou parking public<\/th>\n          <td><strong>Mode 3<\/strong> (CA commercial \u00e0 sortie unique ou double ; ou exception UE Mode 2 \u2264 3,7 kW le cas \u00e9ch\u00e9ant)<\/td>\n          <td>Confirmez le LMS\/DLB optionnel pour \u00e9viter un surdimensionnement du facteur de diversit\u00e9 = 1, v\u00e9rifiez la port\u00e9e de l&#039;OCPP et du MID\/compteur de facturation national sur l&#039;UGS exacte et v\u00e9rifiez l&#039;annexe II \/ art. 5(1) de l&#039;EU AFIR ou le r\u00e8glement britannique sur les points de charge publics de 2023.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Station-service \u00e0 forte consommation d&#039;\u00e9nergie (kWh), axe autoroutier ou plateforme de flotte o\u00f9 le temps d&#039;arr\u00eat ne permet pas de couvrir la consommation \u00e9nerg\u00e9tique quotidienne en courant alternatif.<\/th>\n          <td><strong>Mode 4<\/strong> (chargeur rapide CC externe)<\/td>\n          <td>Estimer l&#039;\u00e9nergie CA rechargeable pendant le temps de stationnement disponible (kW CA disponibles \u00d7 heures de stationnement, en tenant compte des pertes et de la r\u00e9duction de puissance, o\u00f9 les limites CA OBC du v\u00e9hicule sont g\u00e9n\u00e9ralement de 7,4 \u00e0 22 kW et jusqu&#039;\u00e0 43 kW CA sur certains v\u00e9hicules \u00e9lectriques plus anciens tels que les premi\u00e8res Renault ZOE) et comparer avec les kWh requis ; v\u00e9rifier la conformit\u00e9 \u00e0 la norme IEC 61851-23 et la capacit\u00e9 de l&#039;alimentation\/transformateur.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Station-service, d\u00e9p\u00f4t de produits chimiques ou atmosph\u00e8re potentiellement explosive<\/th>\n          <td><strong>Classification des zones dangereuses en premier<\/strong> (avant de choisir un mode de charge)<\/td>\n          <td>Les bornes de recharge pour v\u00e9hicules \u00e9lectriques en mode standard 2\/3\/4 sont con\u00e7ues uniquement pour les emplacements non dangereux ; veuillez v\u00e9rifier les limites de zonage et la conformit\u00e9 Ex\/AHJ avant d&#039;installer une borne de recharge \u00e0 proximit\u00e9 de vapeurs inflammables.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">V\u00e9rifiez toujours les seuils de notification des services publics locaux (par exemple, l&#039;enregistrement aupr\u00e8s du gestionnaire de r\u00e9seau de distribution pour les bornes de recharge fixes) et les normes nationales d&#039;installation \u00e9lectrique avant tout achat. Sur les \u00e9crans \u00e9troits, faites glisser votre doigt horizontalement.<\/p>\n\n  <h2 id=\"mode-2-vs-mode-3-safety-and-standards\">2. S\u00e9curit\u00e9 \u00e9lectrique en mode 2 vs. mode 3\u00a0: quatre limites de conformit\u00e9<\/h2>\n\n  <p>Le passage d&#039;un cordon d&#039;alimentation portable de mode 2 \u00e0 une station fixe de mode 3 modifie quatre niveaux de conformit\u00e9 distincts, chacun ayant une incidence directe sur le dimensionnement du panneau, le choix de la prise et l&#039;approbation du site\u00a0:<\/p>\n\n  <h3 id=\"layer-1-ic-cpd-and-domestic-sockets\">Couche 1 \u2014 Mode 2 IC-CPD et trois niveaux de prises distincts (standard, EV et CEE industriel)<\/h3>\n  <p>Sous <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/66220\" rel=\"nofollow\">CEI 62752:2024<\/a> (\u00c9dition 2.0, publi\u00e9e le 27 mars 2024, rempla\u00e7ant 2016 + A1:2018), un dispositif de protection contre les surintensit\u00e9s (IC-CPD) de mode 2 int\u00e8gre la signalisation pilote de commande, la continuit\u00e9 de la terre et la protection contre les courants de fuite \u00e0 la terre, ainsi que des exigences CEM harmonis\u00e9es avec <strong>CEI 61543<\/strong> et <strong>CEI 61851-21-2<\/strong>et\u2014sous r\u00e9vision <strong>Sous-clause 8.3.1<\/strong> et nouveaux <strong>Sous-clause 9.36<\/strong>\u2014un dispositif de contr\u00f4le de temp\u00e9rature obligatoire d\u00e9tectant la chaleur sur les pi\u00e8ces conductrices \u00e0 l&#039;int\u00e9rieur de la prise domestique.<\/p>\n  <p>\u00c9tant donn\u00e9 que la prise murale et le c\u00e2blage de d\u00e9rivation constituent g\u00e9n\u00e9ralement le goulot d&#039;\u00e9tranglement thermique en mode de charge 2, il est pr\u00e9f\u00e9rable de s\u00e9parer clairement les trois niveaux de prises plut\u00f4t que de traiter toutes les prises de la m\u00eame mani\u00e8re\u00a0:<\/p>\n  <ul>\n    <li><strong>Prises domestiques standard non class\u00e9es\u00a0:<\/strong> L&#039;intensit\u00e9 nominale d&#039;une prise domestique ne suffit pas \u00e0 elle seule \u00e0 d\u00e9terminer si elle convient \u00e0 la recharge prolong\u00e9e d&#039;un v\u00e9hicule \u00e9lectrique. Suivez les recommandations locales et v\u00e9rifiez l&#039;intensit\u00e9 continue admissible pour la prise, le circuit et le cordon d&#039;alimentation install\u00e9s. Au Danemark, par exemple, <a href=\"https:\/\/www.sik.dk\/erhverv\/elinstallationer-og-elanlaeg\/vejledninger\/elinstallationer\/elbiler\/oplad-din-el-bil-sikkert\" rel=\"nofollow\">L&#039;autorit\u00e9 recommande un maximum de 6 A<\/a> pour les charges prolong\u00e9es sur une prise domestique ordinaire et n\u00e9cessite une prise d\u00e9di\u00e9e adapt\u00e9e aux charges \u00e9lev\u00e9es soutenues si la charge est cens\u00e9e d\u00e9passer deux heures d&#039;affil\u00e9e (notez que le BCPP-A1-16 d&#039;EVB commence \u00e0 8 A et ne peut pas \u00eatre utilis\u00e9 pour satisfaire une limite de 6 A).<\/li>\n    <li><strong>Prises domestiques renforc\u00e9es homologu\u00e9es EV et reconnues \u00e0 l&#039;\u00e9chelle nationale\u00a0:<\/strong> Des prises de courant d\u00e9di\u00e9es, con\u00e7ues et test\u00e9es pour un fonctionnement continu avec des v\u00e9hicules \u00e9lectriques, conform\u00e9ment aux r\u00e9glementations nationales, comme celles du Royaume-Uni. <strong>BS 1363-2\/EV<\/strong> (13 A test\u00e9 sous charge cyclique et marqu\u00e9 \u00ab EV \u00bb) ou sorties renforc\u00e9es fran\u00e7aises telles que <a href=\"https:\/\/www.legrand.fr\/pro\/solutions\/prises-et-bornes-de-recharge-pour-vehicules-electriques-ensemble-vers-plus-de-mobilite-verte\" rel=\"nofollow\">Legrand Green&#039;Up<\/a> (jusqu&#039;\u00e0 16 A \/ 3,7 kW lorsqu&#039;il est associ\u00e9 \u00e0 un cordon compatible, un circuit d\u00e9di\u00e9 et des conditions d&#039;installation NF C 15-100).<\/li>\n    <li><strong>Prises industrielles CEE (IEC 60309)\u00a0:<\/strong> Utilis\u00e9 lorsque la charge en mode 2 n\u00e9cessite 16 A ou 32 A (monophas\u00e9 ou triphas\u00e9) en dehors d&#039;un syst\u00e8me de prise domestique renforc\u00e9e reconnu \u00e0 l&#039;\u00e9chelle nationale, n\u00e9cessitant un circuit d\u00e9di\u00e9 v\u00e9rifi\u00e9, une protection RCD\/contre-intensit\u00e9 en amont appropri\u00e9e et des rallonges de cordon z\u00e9ro (explicitement interdites dans les manuels d&#039;installation d&#039;EVB).<\/li>\n  <\/ul>\n\n  <h3 id=\"layer-2-mode-3-rcd-and-dedicated-circuit\">Couche 2 \u2014 Circuits d\u00e9di\u00e9s aux v\u00e9hicules \u00e9lectriques, exception multipoint \u00e0 entr\u00e9e unique et coordination des disjoncteurs diff\u00e9rentiels (IEC 60364-7-722)<\/h3>\n  <p>Au niveau du c\u00e2blage du b\u00e2timent, <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">CEI 60364-7-722:2018<\/a> (\u00c9dition 2.0, publi\u00e9e le 21 septembre 2018) r\u00e9git <strong>tous les circuits d&#039;alimentation d\u00e9di\u00e9s aux v\u00e9hicules \u00e9lectriques<\/strong>\u2014couvrant \u00e0 la fois les bornes fixes de mode 3 et les prises de courant d\u00e9di\u00e9es aux v\u00e9hicules \u00e9lectriques de mode 2. Parall\u00e8lement \u00e0 <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/EV_charging_-_electrical_installation_design\" rel=\"nofollow\">Guide de conception d&#039;installation de v\u00e9hicules \u00e9lectriques de Schneider Electric<\/a>, conception de panneau en forme de quatre clauses\u00a0:<\/p>\n  <ul>\n    <li><strong>Circuit d\u00e9di\u00e9 aux v\u00e9hicules \u00e9lectriques et absence de conducteur PEN (articles 722.314.101 et 722.312.2.1)\u00a0:<\/strong> Un circuit d\u00e9di\u00e9 doit \u00eatre pr\u00e9vu pour le transfert d&#039;\u00e9nergie vers\/depuis le v\u00e9hicule \u00e9lectrique, et dans les syst\u00e8mes TN, le circuit final alimentant un point de connexion ne doit pas inclure de conducteur PEN combin\u00e9.<\/li>\n    <li><strong>Protection individuelle vs. exception \u00e0 entr\u00e9e unique multipoint (article 722.533.101)\u00a0:<\/strong> Chaque point de connexion doit \u00eatre aliment\u00e9 individuellement par un circuit final prot\u00e9g\u00e9 contre les surintensit\u00e9s.<em>sauf<\/em> o\u00f9 la norme IEC 61851-1 EVSE comportant plusieurs points de connexion int\u00e8gre les dispositifs de protection internes contre les surintensit\u00e9s requis par <strong>CEI 61851-1:2017, 13.1<\/strong>Pour les chargeurs \u00e0 double sortie (tels que le BCPCM \u00e0 entr\u00e9e unique d&#039;EVB ou un BCPCV command\u00e9 avec une ou deux entr\u00e9es), v\u00e9rifiez s\u00e9par\u00e9ment le c\u00e2ble d&#039;alimentation principal, la protection interne par point et le tableau de distribution en amont sur le sch\u00e9ma de c\u00e2blage de chaque mod\u00e8le.<\/li>\n    <li><strong>Facteur de diversit\u00e9 = 1 Sans contr\u00f4le de charge (article 722.311)\u00a0:<\/strong> Les installations \u00e0 plusieurs chargeurs doivent supposer une pleine charge simultan\u00e9e (facteur de diversit\u00e9 = <strong>1<\/strong>) sauf si la gestion de charge v\u00e9rifi\u00e9e (LMS \/ DLB - une fonctionnalit\u00e9 optionnelle sur de nombreux mod\u00e8les EVSE) limite activement le courant agr\u00e9g\u00e9.<\/li>\n    <li><strong>Protection individuelle contre les surintensit\u00e9s de 30 mA + protection CC lisse, ou s\u00e9paration \u00e9lectrique (articles 722.411.3.3, 722.531.2.101 \/ HD 722.531.3.101 et 722.413)\u00a0:<\/strong> Chaque point de raccordement CA prot\u00e9g\u00e9 par d\u00e9connexion automatique n\u00e9cessite un \u2264<strong>30 mA<\/strong> Disjoncteur diff\u00e9rentiel (type A minimum) coupant tous les conducteurs sous tension. Sauf disposition contraire de la clause <strong>722.413<\/strong> s\u00e9paration \u00e9lectrique via une <strong>CEI 61558-2-4<\/strong> transformateur d&#039;isolement (\u2264500 V, alimentant <strong>un seul v\u00e9hicule \u00e9lectrique<\/strong>Si le mode 3 est utilis\u00e9, chaque point \u00e9quip\u00e9 d&#039;une prise ou d&#039;un connecteur IEC 62196 n\u00e9cessite \u00e9galement des mesures de protection contre les courants de d\u00e9faut continus, soit un <strong>DDR de type B<\/strong> (CEI 62423) <em>ou<\/em> un <strong>Dispositif diff\u00e9rentiel r\u00e9siduel (DDR) de type A\/F associ\u00e9 \u00e0 un d\u00e9tecteur de courant continu diff\u00e9rentiel (DCR-DD, seuil continu lisse de 6 mA) conforme \u00e0 la norme <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32963\" rel=\"nofollow\">CEI 62955:2018<\/a><\/strong>.<\/li>\n  <\/ul>\n  <p><strong>Choisir la protection d&#039;un bo\u00eetier mural EVB.<\/strong> Le <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Wall-mounted-AC-EV-Charger-2024.09.06.pdf\">bo\u00eetier mural OCPP de premi\u00e8re g\u00e9n\u00e9ration<\/a> et <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-2nd-Generation-OCPP-Wall-mounted-AC-EV-Charger-2025.11.04.pdf\">bo\u00eetier mural \u00e0 c\u00e2ble fixe de deuxi\u00e8me g\u00e9n\u00e9ration<\/a> Les deux mod\u00e8les int\u00e8grent un capteur de courant de fuite de 6 mA. Consultez le sch\u00e9ma de c\u00e2blage du mod\u00e8le s\u00e9lectionn\u00e9 pour identifier le dispositif de coupure en cas de d\u00e9faut et le disjoncteur diff\u00e9rentiel (DDR) requis en amont. Pour un DDR de type A ou F associ\u00e9 \u00e0 un module de commande diff\u00e9rentielle (RDC-DD), v\u00e9rifiez la documentation IEC 62955 applicable aupr\u00e8s d&#039;EVB.<\/p>\n\n  <h3 id=\"layer-3-emc-earthing-and-public-billing\">Couches 3 et 4 \u2014 Classe CEM A vs B, exception au mode 2 AFIR de l&#039;UE, mise \u00e0 la terre nationale et zones non dangereuses<\/h3>\n  <ul>\n    <li><strong>AFIR de l&#039;UE (<a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2023\/1804\/2026-01-08\/eng\" rel=\"nofollow\">R\u00e8glement (UE) 2023\/1804, consolid\u00e9 le 8 janvier 2026<\/a>) \u2014 Exception de socket en mode 2 et terminal de paiement du pool\u00a0:<\/strong> Sous <strong>Annexe II, Section 1.1<\/strong>, bornes de recharge CA \u00e0 puissance normale pour v\u00e9hicules \u00e9lectriques l\u00e9gers install\u00e9es ou r\u00e9nov\u00e9es \u00e0 partir de <strong>8 janvier 2026<\/strong> doit \u00eatre \u00e9quip\u00e9, pour l&#039;interop\u00e9rabilit\u00e9, au moins avec <strong>EN IEC 62196-2:2022 Type 2<\/strong> prises\/connecteurs\u2014<strong>ou, si la puissance est \u2264 3,7 kW et principalement destin\u00e9e \u00e0 la recharge en mode 2, les prises de courant sont conformes \u00e0 la norme IEC 60884-1:2022.<\/strong>. Par ailleurs, <strong>Article 5(1)<\/strong> d\u00e9finit des r\u00e8gles de paiement ad hoc pour les points de paiement payants accessibles au public d\u00e9ploy\u00e9s \u00e0 partir du 13 avril 2024 (les points gratuits sont exempt\u00e9s, un terminal ou appareil de paiement peut desservir plusieurs points). <strong>au sein de la m\u00eame piscine de recharge<\/strong>et les bornes TEN-T\/stationnement s\u00e9curis\u00e9 existantes d&#039;une puissance \u2265 50 kW s&#039;appliquent \u00e0 compter du 1er janvier 2027) ; les sites britanniques suivent la <a href=\"https:\/\/www.gov.uk\/government\/publications\/the-public-charge-point-regulations-2023-guidance\/public-charge-point-regulations-2023-guidance\" rel=\"nofollow\">R\u00e8glement de 2023 sur les bornes de recharge publiques<\/a>.<\/li>\n    <li><strong>CEI 61851-21-2 Classe A vs. Classe B\u00a0:<\/strong> Comme indiqu\u00e9 dans le <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/EV_charging_station_design\" rel=\"nofollow\">Guide de conception des bornes de recharge pour v\u00e9hicules \u00e9lectriques de Schneider Electric<\/a>, <strong>Classe B<\/strong> Les \u00e9quipements de recharge hors-bord conviennent aux \u00e9tablissements r\u00e9sidentiels et aux sites directement raccord\u00e9s \u00e0 un r\u00e9seau r\u00e9sidentiel basse tension, tandis que <strong>Classe A<\/strong> L&#039;utilisation de cet \u00e9quipement est limit\u00e9e aux lieux non r\u00e9sidentiels.<\/li>\n    <li><strong>M\u00e9trologie nationale de la mise \u00e0 la terre et de la facturation\u00a0:<\/strong> Les concepteurs de projets doivent v\u00e9rifier les r\u00e8gles de mise \u00e0 la terre sp\u00e9cifiques \u00e0 chaque pays\u00a0; par exemple, les installations au Royaume-Uni doivent confirmer les mesures de protection exactes pour les alimentations PME (TN-CS) et les emplacements de charge ext\u00e9rieurs par rapport \u00e0 l\u2019\u00e9dition actuelle de <a href=\"https:\/\/electrical.theiet.org\/bs-7671-18th-edition-wiring-regulations\/ensure-you-are-up-to-date-with-bs-7671\" rel=\"nofollow\">BS 7671 Section 722<\/a>Certains v\u00e9hicules \u00e9lectriques limitent la charge en modes 1 \u00e0 3 sur les syst\u00e8mes de mise \u00e0 la terre IT. Lorsque la facturation au kWh s&#039;applique, v\u00e9rifiez la port\u00e9e de l&#039;indicateur de charge int\u00e9gr\u00e9e (ou de l&#039;\u00e9talonnage national) par mod\u00e8le et par phase\u00a0; par exemple, la fiche technique de Mennekes AMTRON limite son homologation MID int\u00e9gr\u00e9e \u00e0 <strong>connexion triphas\u00e9e uniquement<\/strong>.<\/li>\n    <li><strong>Limites environnementales et non dangereuses des emplacements\u00a0:<\/strong> Conform\u00e9ment \u00e0 la norme IEC 61851-1, les \u00e9quipements de base fonctionnent jusqu&#039;\u00e0 2\u00a0000\u00a0m d&#039;altitude et jusqu&#039;\u00e0 \u221225\u00a0\u00b0C en ext\u00e9rieur (\u22125\u00a0\u00b0C en int\u00e9rieur). Les bornes de recharge standard pour v\u00e9hicules \u00e9lectriques sont destin\u00e9es \u00e0\u00a0: <strong>uniquement les emplacements non dangereux<\/strong>\u2014Comme indiqu\u00e9 dans le manuel d&#039;installation BCPCV d&#039;EVB, ne jamais installer \u00e0 proximit\u00e9 de vapeurs inflammables, explosives ou combustibles sans qualification distincte pour les zones dangereuses.<\/li>\n  <\/ul>\n\n  <h2 id=\"evb-mode-2-and-mode-3-hardware-comparison\">3. Choisir un chargeur EVB de mode 2 ou de mode 3<\/h2>\n\n  <p>Commencez par \u00e9valuer la puissance disponible sur place. Pour une borne de recharge fixe, d\u00e9terminez si les conducteurs apporteront leur propre c\u00e2ble ou utiliseront celui fourni par la borne. Les fiches techniques sp\u00e9cifiques \u00e0 chaque mod\u00e8le, pr\u00e9sent\u00e9es dans le tableau, proviennent de\u2026 <a href=\"https:\/\/www.evb.com\/fr\/guides-videos\/\">Centre de t\u00e9l\u00e9chargement EVB<\/a>.<\/p>\n\n  <figure class=\"evb-article-figure\">\n    <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-mode-2-vs-mode-3-hardware-and-rcd-matrix.webp\" target=\"_blank\" rel=\"noopener\" title=\"Aper\u00e7u des chemins de protection IEC 60364-7-722 en pleine r\u00e9solution et du format EVB\">\n      <img src=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-mode-2-vs-mode-3-hardware-and-rcd-matrix.webp\" alt=\"Diagramme neutre en termes de langue montrant trois options de protection IEC 60364-7-722 Mode 3 (30 mA Type A ou F plus IEC 62955 RDC-DD, 30 mA Type B RCD ou transformateur d&#039;isolement Clause 722.413 pour un EV) au-dessus de quatre silhouettes minimalistes de facteur de forme EVB : BCPP-A1-16, BCPP-A1-32, BCP-A2N\/B2N et BCPCM\/BCPCV.\" width=\"920\" height=\"480\" loading=\"lazy\" decoding=\"async\" \/>\n    <\/a>\n    <figcaption>En haut\u00a0: Chemins de protection CA autoris\u00e9s selon la norme IEC 60364-7-722 pour les points du mode 3 (disjoncteur diff\u00e9rentiel 30\u00a0mA type A\/F + disjoncteur diff\u00e9rentiel 6\u00a0mA CC IEC 62955, disjoncteur diff\u00e9rentiel 30\u00a0mA type B selon la norme IEC 62423, ou s\u00e9paration \u00e9lectrique selon la clause 722.413 via un transformateur d\u2019isolement IEC 61558-2-4 alimentant un seul v\u00e9hicule \u00e9lectrique). En bas\u00a0: Quatre formats de chargeurs EVB. Les chargeurs marqu\u00e9s d\u2019un ast\u00e9risque sont indiqu\u00e9s par un ast\u00e9risque. <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2024\/11\/7KW-wall-mountedportable-ac-ev-charger-1112.pdf\">BCPP-A1-32<\/a> Sa longueur standard est de 5 m. Les mod\u00e8les portables \u00e0 \u00e9cran tactile du tableau ci-dessous ont une longueur standard de 7 m. Appuyez ou cliquez pour afficher la r\u00e9solution maximale.<\/figcaption>\n  <\/figure>\n\n  <p class=\"evb-table-title\" id=\"tbl-evb-title\">Sp\u00e9cifications des chargeurs EVB Mode 2 et Mode 3 par mod\u00e8le<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-evb-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">S\u00e9rie EVB et lien<\/th>\n          <th scope=\"col\">Mode de charge et fiche technique<\/th>\n          <th scope=\"col\">Puissance, tension et courant<\/th>\n          <th scope=\"col\">Connexions et fonctionnalit\u00e9s<\/th>\n          <th scope=\"col\">Que faut-il pr\u00e9ciser lors de la commande ?<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/fr\/article-de-produit\/chargeur-portable-ca-ev-2\/\">Chargeur portable BCPP-A1-16<\/a><\/th>\n          <td><strong>Mode 2<\/strong>. Le <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-Unsmart-Portable-AC-EV-Charger-2025.08.13.pdf\">Fiche technique BCPP-A1-16<\/a> liste les normes IEC 62752 et IEC 61851-21-2.<\/td>\n          <td>Jusqu&#039;\u00e0 <strong>3,7 kW<\/strong> 230 V monophas\u00e9. R\u00e9glable de 8 \u00e0 16 A.<\/td>\n          <td>IP66. Longueur hors tout standard 7 m. Plage de fonctionnement \u221230 \u00e0 +50 \u00b0C, en dessous de 2 000 m.<\/td>\n          <td>Choisissez la prise adapt\u00e9e au site. La prise britannique est con\u00e7ue pour 13 A \u00e0 250 V et la prise am\u00e9ricaine pour 15 A \u00e0 125 V. V\u00e9rifiez l&#039;intensit\u00e9 admissible en continu et la protection thermique de la prise pour l&#039;installation. Le r\u00e9glage minimal de l&#039;appareil est de 8 A.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/fr\/article-de-produit\/support-mural-portable-2-en-1\/\">Chargeur portable intelligent BCPP-A2N-32 \/ BCPP-AT2N-32<\/a><\/th>\n          <td><strong>Mode 2<\/strong> avec une prise CEE industrielle. Voir le <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-Smart-Portable-Wall-mounted-AC-EV-Charger-2024.09.06.pdf\">fiche technique pour appareil portable\/mural intelligent<\/a>.<\/td>\n          <td><strong>7,4 kW<\/strong> \u00e0 230 V monophas\u00e9 (A2N) ou <strong>22 kW<\/strong> triphas\u00e9 400 V (AT2N). Les deux sont r\u00e9glables de 6 \u00e0 32 A.<\/td>\n          <td>\u00c9cran tactile de 4,3 pouces. La fiche technique indique un indice de protection IP65 et une longueur hors tout standard de 7 m. L&#039;\u00e9quilibrage dynamique de la charge est optionnel.<\/td>\n          <td>V\u00e9rifiez que la prise CEE correspond \u00e0 l&#039;alimentation du site. Si le projet requiert un indice de protection IP66, veuillez l&#039;indiquer dans votre demande de devis afin qu&#039;EVB puisse confirmer le bo\u00eetier adapt\u00e9 \u00e0 l&#039;unit\u00e9 command\u00e9e.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Bo\u00eetier mural OCPP de premi\u00e8re g\u00e9n\u00e9ration \u00b7 <a href=\"https:\/\/www.evb.com\/fr\/article-de-produit\/chargeur-ve-ac-avec-cable-2\/\">c\u00e2ble fixe<\/a> ou <a href=\"https:\/\/www.evb.com\/fr\/article-de-produit\/chargeur-ve-ac-avec-prise-2\/\">Prise de type 2<\/a><\/th>\n          <td><strong>Mode 3<\/strong>. Le <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Wall-mounted-AC-EV-Charger-2024.09.06.pdf\">fiche technique du bo\u00eetier mural de premi\u00e8re g\u00e9n\u00e9ration<\/a> couvre les deux connexions.<\/td>\n          <td>Les mod\u00e8les 32 A d\u00e9livrent jusqu&#039;\u00e0 <strong>7,4 kW<\/strong> monophas\u00e9 ou <strong>22 kW<\/strong> triphas\u00e9. Les versions 16 A ont une puissance nominale de 3,7 ou 11 kW, respectivement.<\/td>\n          <td>C\u00e2ble fixe de 5 m (Cas C), IP65, sur BCP-A2N-P \/ BCP-AT2N-P. Prise de type 2 pour un c\u00e2ble d\u00e9tachable (Cas B), IP55, sur BCP-B2N-P \/ BCP-BT2N-P.<\/td>\n          <td>Choisissez d&#039;abord le type de connexion et le nombre de phases. Les quatre mod\u00e8les 32 A sont compatibles avec la norme OCPP 1.6-J. L&#039;\u00e9quilibrage dynamique de la charge et un compteur MID externe sont disponibles en option.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/fr\/article-de-produit\/2nd-generation-ocpp-wall-mounted-ac-ev-charger\/\">Bo\u00eetier mural OCPP de deuxi\u00e8me g\u00e9n\u00e9ration<\/a> \u00b7 BCP-A2M-P \/ BCP-AT2M-P<\/th>\n          <td><strong>Mode 3<\/strong> avec un c\u00e2ble fixe. Voir le <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-2nd-Generation-OCPP-Wall-mounted-AC-EV-Charger-2025.11.04.pdf\">fiche technique du bo\u00eetier mural de deuxi\u00e8me g\u00e9n\u00e9ration<\/a>.<\/td>\n          <td>Le BCP-A2M-P d\u00e9livre jusqu&#039;\u00e0 <strong>7,4 kW<\/strong> \u00e0 230 V monophas\u00e9. Le BCP-AT2M-P d\u00e9livre jusqu&#039;\u00e0 <strong>22 kW<\/strong> \u00e0 400 V triphas\u00e9. Les deux sont des mod\u00e8les 32 A.<\/td>\n          <td>C\u00e2ble fixe de 5 m (Cas C), IP65, IK10 et OCPP 1,6-J. L&#039;\u00e9quilibrage dynamique de la charge et un compteur MID externe sont en option.<\/td>\n          <td>Pour un site limit\u00e9 \u00e0 16 A par phase, sp\u00e9cifiez BCP-A2M-P-16 (3,7 kW) ou BCP-AT2M-P-16 (11 kW).<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/fr\/article-de-produit\/chargeur-ev-type-2-mode-3\/\">Chargeur mural \u00e0 double c\u00e2ble BCPCM<\/a><\/th>\n          <td><strong>Mode 3<\/strong> avec deux c\u00e2bles fixes. Voir le <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Wall-mounted-Dual-Cable-AC-EV-Charger-Metal-Enclosure-2025.04.07.pdf\">Fiche technique du c\u00e2ble double BCPCM<\/a>.<\/td>\n          <td>BCPCM-C2N-P\u00a0: <strong>2 \u00d7 7,4 kW<\/strong> \u00e0 230 V monophas\u00e9. \u00c0 400 V triphas\u00e9, le BCPCM-CT2N-P-16 fournit <strong>2 \u00d7 11 kW<\/strong> et BCPCM-CT2N-P <strong>2 \u00d7 22 kW<\/strong>.<\/td>\n          <td>Deux c\u00e2bles de 5 m, IP65, deux compteurs MID et OCPP 1,6-J.<\/td>\n          <td>Les deux points de charge partagent une seule entr\u00e9e d&#039;alimentation. Utilisez le sch\u00e9ma de c\u00e2blage du mod\u00e8le s\u00e9lectionn\u00e9 pour dimensionner le c\u00e2ble d&#039;alimentation et coordonner la protection de chaque point.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/fr\/article-de-produit\/chargeur-de-vehicule-electrique-a-courant-alternatif-monte-au-sol-avec-prise\/\">Chargeur double BCPCV mont\u00e9 au sol<\/a> \u00b7 DT2N \/ CT2N<\/th>\n          <td><strong>Mode 3<\/strong>Voir le <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Floor-mounted-AC-EV-Charger-2025.07.11.pdf\">Fiche technique du socle BCPCV s\u00e9rie N<\/a>.<\/td>\n          <td>Sur un r\u00e9seau triphas\u00e9 de 400 V, les mod\u00e8les BCPCV-DT2N-P et BCPCV-CT2N-P sont class\u00e9s <strong>2 \u00d7 22 kW<\/strong>Leurs variantes -16 sont class\u00e9es <strong>2 \u00d7 11 kW<\/strong>.<\/td>\n          <td>Le DT2N poss\u00e8de deux prises. Le CT2N est \u00e9quip\u00e9 de deux c\u00e2bles fixes de 5 m. Les deux mod\u00e8les offrent une protection IP54, un compteur int\u00e9gr\u00e9 et une alimentation OCPP 1.6-J.<\/td>\n          <td>Sp\u00e9cifiez le type d&#039;alimentation (simple ou double) et le compteur de facturation requis pour le site. Figure 4 de la <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2024\/02\/Floor-Mounted-AC-EV-Charger-0228.pdf\">Manuel d&#039;installation BCPCV<\/a> Illustre la configuration \u00e0 double entr\u00e9e. Utilisez le sch\u00e9ma de c\u00e2blage fourni pour la configuration command\u00e9e.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">Pour les zones commerciales o\u00f9 l&#039;\u00e9nergie CA renouvelable pendant le temps de stationnement disponible (puissance CA disponible en kW \u00d7 dur\u00e9e de stationnement, en tenant compte des pertes et du d\u00e9classement) est inf\u00e9rieure \u00e0 la consommation quotidienne en kWh, voir le mode 4 de l&#039;EVB. <a href=\"https:\/\/www.evb.com\/fr\/article-de-produit\/floor-mounted-dc-2-guns-ev-dc-fast-charger\/\">Chargeurs rapides CC \u00e0 double canon BDC 60\u2013320 kW<\/a>Balayez horizontalement sur les \u00e9crans \u00e9troits.<\/p>\n\n  <h2 id=\"iec-61851-charging-modes-comparison\">4. R\u00e9f\u00e9rence compl\u00e8te \u00e0 la norme IEC 61851-1\u00a0: O\u00f9 s\u2019int\u00e8grent les modes 1 et 4 (mode Plus vs bo\u00eetier vs connecteur)<\/h2>\n\n  <p>Sous <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/33644\" rel=\"nofollow\">CEI 61851-1:2017<\/a> (\u00c9dition 3.0, borne de recharge conductrice pour v\u00e9hicules \u00e9lectriques (EVSE) de puissance nominale \u2264<strong>1\u00a0000 V CA ou 1\u00a0500 V CC<\/strong>; voir aussi le <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/Electric_Vehicle_and_EV_charging_fundamentals\" rel=\"nofollow\">Guide des principes fondamentaux des v\u00e9hicules \u00e9lectriques de Schneider Electric<\/a>Les modes 1 \u00e0 3 alimentent en courant alternatif le chargeur embarqu\u00e9 du v\u00e9hicule, tandis que <strong>Le mode 4 fournit du courant continu directement au v\u00e9hicule \u00e0 partir d&#039;une station externe.<\/strong> (<a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32973\" rel=\"nofollow\">CEI 61851-23:2023<\/a> couvre \u00e0 la fois les chargeurs CC externes \u00e0 entr\u00e9e CA et \u00e0 entr\u00e9e CC (une armoire redresseuse aliment\u00e9e en CA n&#039;en est que l&#039;exemple le plus courant) :<\/p>\n\n  <p class=\"evb-table-title\" id=\"tbl-modes-title\">Norme CEI 61851-1 Modes de charge 1 \u00e0 4\u00a0: Caract\u00e9ristiques, chemin de contr\u00f4le et limites pratiques<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-modes-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">Mode de charge<\/th>\n          <th scope=\"col\">Interface et mat\u00e9riel d&#039;alimentation<\/th>\n          <th scope=\"col\">\u00c9valuations standard<\/th>\n          <th scope=\"col\">Pilote de contr\u00f4le (CP) et protection<\/th>\n          <th scope=\"col\">Port\u00e9e pratique et mise en garde importante<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\">Mode 1<\/th>\n          <td>Prise secteur standard non d\u00e9di\u00e9e avec un simple cordon et une fiche<\/td>\n          <td>\u2264<strong>16 A<\/strong>; \u2264<strong>250 V CA<\/strong> (1P) ou \u2264<strong>480 V CA<\/strong> (3P)<\/td>\n          <td><strong>Pas de signalisation CP\/PP<\/strong>; repose uniquement sur la protection du circuit existant du b\u00e2timent<\/td>\n          <td>L&#039;utilisation de ces installations est restreinte ou interdite pour les v\u00e9hicules \u00e9lectriques routiers dans de nombreux codes de c\u00e2blage nationaux en raison des risques de surcharge des circuits partag\u00e9s et d&#039;incendie\/d&#039;\u00e9lectrocution.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Mode 2<\/th>\n          <td>Prise domestique, prise domestique pour v\u00e9hicules \u00e9lectriques ou prise industrielle CEE via un appareil portable <strong>IC-CPD<\/strong> (<a href=\"https:\/\/webstore.iec.ch\/en\/publication\/66220\" rel=\"nofollow\">CEI 62752:2024<\/a>)<\/td>\n          <td>\u2264<strong>32 A<\/strong>; \u2264<strong>250 V CA<\/strong> (1P) ou \u2264<strong>480 V CA<\/strong> (3P)<\/td>\n          <td><strong>C\u00e2ble IC-CPD<\/strong> assure la communication CP et la protection contre les fuites de courant\u00a0; l\u2019\u00e9dition 2.0 de 2024 (sous-sections 8.3.1 et 9.36) exige la d\u00e9tection de temp\u00e9rature sur les parties conductrices des prises domestiques.<\/td>\n          <td>Id\u00e9al pour les voyages\/secours, prises homologu\u00e9es pour v\u00e9hicules \u00e9lectriques (par exemple, BS 1363-2\/EV, Green&#039;Up) ou prises CEE v\u00e9rifi\u00e9es ; l&#039;annexe II \u00a71.1 de l&#039;AFIR de l&#039;UE autorise les points de courant alternatif l\u00e9gers de puissance normale de mode 2 \u22643,7 kW \u00e0 utiliser des prises de courant IEC 60884-1:2022.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Mode 3<\/th>\n          <td>Borne d&#039;alimentation pour v\u00e9hicule \u00e9lectrique (bo\u00eetier mural ou borne sur socle) connect\u00e9e en permanence \u00e0 un <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">CEI 60364-7-722<\/a> circuit<\/td>\n          <td>Commun\u00e9ment <strong>3,7\u201322 kW<\/strong> (16 A \/ 32 A, 1P ou 3P); <strong>~43,5 kW<\/strong> sur des configurations sp\u00e9cifiques 400 V triphas\u00e9es 63 A<\/td>\n          <td><strong>Commande du chargeur et commutation du contacteur :<\/strong> Signalisation CP\/PP, contacteur et v\u00e9rification PE. <strong>Protection du circuit d&#039;installation (IEC 60364-7-722)\u00a0:<\/strong> Disjoncteur diff\u00e9rentiel de type A\/F 30 mA + disjoncteur diff\u00e9rentiel CC IEC 62955 6 mA, disjoncteur diff\u00e9rentiel de type B 30 mA ou s\u00e9paration \u00e9lectrique selon la clause 722.413 (v\u00e9rifier l&#039;emplacement du panneau interne ou en amont selon le sch\u00e9ma de c\u00e2blage du SKU)<\/td>\n          <td>Configuration de base pour les sites r\u00e9sidentiels, de travail et publics utilisant la climatisation au quotidien ; les compteurs de gestion de charge (DLB), OCPP et MID sont des options d\u00e9pendantes du mod\u00e8le.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Mode 4<\/th>\n          <td>Station de recharge CC externe (<a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32973\" rel=\"nofollow\">CEI 61851-23:2023<\/a>; Alimentation par entr\u00e9e CA ou CC)<\/td>\n          <td>Alimentation \u2264 1\u00a0000 V CA \/ 1\u00a0500 V CC\u00a0; sortie \u2264<strong>1\u00a0500 V CC<\/strong> (g\u00e9n\u00e9ralement 50\u2013480 kW+)<\/td>\n          <td>Communication BMS num\u00e9rique de haut niveau, surveillance de l&#039;isolation, s\u00e9paration \u00e9lectrique, c\u00e2ble de type C reli\u00e9<\/td>\n          <td>Fournit du courant continu directement \u00e0 la batterie, contournant les limites de puissance du chargeur embarqu\u00e9 du v\u00e9hicule (g\u00e9n\u00e9ralement de 7,4 \u00e0 22 kW\u00a0; jusqu\u2019\u00e0 43 kW en courant alternatif sur certains v\u00e9hicules \u00e9lectriques plus anciens, comme les premiers mod\u00e8les). <a href=\"https:\/\/www.press.renault.co.uk\/releases\/502\" rel=\"nofollow\">Renault ZOE<\/a>).<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">Compilation bas\u00e9e sur les normes IEC 61851-1:2017, IEC 62752:2024, IEC 60364-7-722:2018, IEC 62955:2018, IEC 61851-23:2023 et le Guide d&#039;installation \u00e9lectrique de Schneider Electric. Sur les \u00e9crans \u00e9troits, faites glisser votre doigt horizontalement.<\/p>\n\n  <h3 id=\"mode-vs-case-vs-type-vs-level\">Ne confondez pas les modes de charge, les bo\u00eetiers de connexion, les connecteurs et les niveaux nord-am\u00e9ricains.<\/h3>\n  <ul>\n    <li><strong>Mode de charge (modes 1 \u00e0 4 de la norme CEI 61851-1)\u00a0:<\/strong> D\u00e9finit l&#039;architecture d&#039;approvisionnement et l&#039;emplacement des syst\u00e8mes de contr\u00f4le et de protection.<\/li>\n    <li><strong>Bo\u00eetier de connexion (cas A, B et C de la norme CEI 61851-1)\u00a0:<\/strong> D\u00e9finit la fixation du c\u00e2ble \u2014<strong>Cas A<\/strong> (fix\u00e9 au v\u00e9hicule), <strong>Cas B<\/strong> (d\u00e9tachables aux deux extr\u00e9mit\u00e9s, par exemple les c\u00e2bles de mode 2 ou les bornes de prise de mode 3), et <strong>Cas C<\/strong> (reli\u00e9 en permanence \u00e0 la borne de recharge pour v\u00e9hicules \u00e9lectriques).<\/li>\n    <li><strong>Famille de connecteurs (IEC 62196 \/ SAE J1772 \/ SAE J3400)\u00a0:<\/strong> D\u00e9finit la g\u00e9om\u00e9trie physique de la prise\u00a0: CA type\u00a01 ou type\u00a02\u00a0; CC CCS1, CCS2 ou CHAdeMO\u00a0; et nord-am\u00e9ricaine <strong>NACS (<a href=\"https:\/\/driveelectric.gov\/charging-connector\" rel=\"nofollow\">SAE J3400<\/a>)<\/strong>, qui soutient <strong>\u00e0 la fois monophas\u00e9 CA et CC<\/strong> via un connecteur compact.<\/li>\n    <li><strong>Classification des tarifs nord-am\u00e9ricains (<a href=\"https:\/\/afdc.energy.gov\/fuels\/electricity-stations\" rel=\"nofollow\">D\u00e9partement de l&#039;\u00c9nergie des \u00c9tats-Unis AFDC<\/a>):<\/strong> Groupes facturant comme <strong>Niveau 1 de la climatisation<\/strong> (120 V), <strong>Niveau 2 de la climatisation<\/strong> (208\/240 V), et <strong>Charge rapide en courant continu<\/strong> (parfois appel\u00e9 famili\u00e8rement \u00ab Niveau 3 \u00bb) \u2014 il ne s\u2019agit pas d\u2019un simple changement de nom des modes CEI.<\/li>\n  <\/ul>\n\n  <h2 id=\"north-america-ul-2594-parallel\">5. Note r\u00e9gionale\u00a0: Correspondance avec les normes UL 2594 et UL 2231 en Am\u00e9rique du Nord<\/h2>\n\n  <p>Pour les flottes internationales d\u00e9ploy\u00e9es sur les r\u00e9seaux IEC et nord-am\u00e9ricains, veuillez sp\u00e9cifier les listes r\u00e9gionales s\u00e9par\u00e9ment\u00a0:<\/p>\n  <ul>\n    <li><strong><a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2594\" rel=\"nofollow\">ANSI\/UL 2594<\/a> (\u00c9dition 3 active, 15 d\u00e9cembre 2022)<\/strong> r\u00e9git la conductivit\u00e9 <strong>CA<\/strong> \u00c9quipements d&#039;alimentation pour v\u00e9hicules \u00e9lectriques (\u2264 1\u00a0000\u00a0V CA, 50\/60\u00a0Hz)\u00a0; exemples d&#039;\u00e9quipements couverts par la clause\u00a01.2\u00a0: <strong>ensembles de cordons d&#039;alimentation pour v\u00e9hicules \u00e9lectriques<\/strong>, <strong>stations de recharge pour v\u00e9hicules \u00e9lectriques fix\u00e9es en place<\/strong>, <strong>stations de recharge fixes pour v\u00e9hicules \u00e9lectriques<\/strong>, et <strong>bornes de recharge fixes pour v\u00e9hicules \u00e9lectriques<\/strong> (La 3e \u00e9dition a supprim\u00e9 l&#039;ancienne exigence selon laquelle les unit\u00e9s de plus de 125 V devaient \u00eatre fix\u00e9es en place).<\/li>\n    <li><strong><a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2231-1\" rel=\"nofollow\">ANSI\/UL 2231-1<\/a> (\u00c9dition 3, 6 novembre 2026) &amp; <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2231-2\" rel=\"nofollow\">UL 2231-2<\/a> (r\u00e9vis\u00e9 le 15 d\u00e9cembre 2020)<\/strong> couvrir les syst\u00e8mes de protection du personnel (tels que CCID) pour les circuits d&#039;alimentation des v\u00e9hicules \u00e9lectriques en Am\u00e9rique du Nord.<\/li>\n    <li><strong>Points pratiques \u00e0 retenir\u00a0:<\/strong> Garder <strong>Niveau 2 de la climatisation am\u00e9ricaine<\/strong> distinct des modes IEC 2 et 3, car le mode IEC 2 est limit\u00e9 \u00e0 <strong>32 A<\/strong>L&#039;appellation \u00ab\u00a0prise avec cordon et fiche nord-am\u00e9ricaine 240\u00a0V \/ 40\u00a0A\u00a0\u00bb ou \u00ab\u00a0station c\u00e2bl\u00e9e 48\u00a0A\u201380\u00a0A conforme \u00e0 la norme UL\u00a02594\u00a0\u00bb d\u00e9crit simplement les m\u00e9thodes de connexion et de montage (v\u00e9rifiez la cat\u00e9gorie d&#039;installation UL\u00a02594 du mod\u00e8le concern\u00e9 lors de l&#039;achat) et non les modes CEI. Indiquez toujours explicitement la norme r\u00e9gionale applicable (CE\/CB\/UKCA + CEI\u00a061851-1 \/ CEI\u00a062752 ou UL\/CSA + UL\u00a02594 \/ UL\u00a02231 + NEC\/CEC) dans les demandes de prix intermarch\u00e9s.<\/li>\n  <\/ul>\n\n  <h2 id=\"rfq-and-commissioning-checklist\">6. Liste de contr\u00f4le de pr\u00e9commande et de mise en service pour les projets en mode 2 et en mode 3<\/h2>\n\n  <div class=\"evb-checklist\">\n    <h3>5 v\u00e9rifications techniques avant l&#039;\u00e9mission d&#039;un bon de commande<\/h3>\n    <ol>\n      <li><strong>Dimensionnement par rapport aux quatre plafonds (r\u00e9seau, borne de recharge pour v\u00e9hicules \u00e9lectriques, c\u00e2ble, chargeur embarqu\u00e9 du v\u00e9hicule) + kWh journalier\u00a0:<\/strong> Faites correspondre la demande \u00e9nerg\u00e9tique quotidienne et le temps de s\u00e9jour au mode 2 (alimentation de secours \/ prise pour VE \/ CEE), au mode 3 (CA quotidien) ou au mode 4 (CC hors-bord), et sp\u00e9cifiez la connexion (cas C) par rapport \u00e0 la prise (cas B).<\/li>\n      <li><strong>Coordonnez le chargeur et le tableau de distribution.<\/strong> Demandez le sch\u00e9ma de c\u00e2blage du mod\u00e8le et les dispositifs de protection en amont recommand\u00e9s. Si le dispositif utilise un DDR de type A ou F avec RDC-DD, v\u00e9rifiez la conformit\u00e9 avec la norme CEI 62955 relative \u00e0 la d\u00e9tection et \u00e0 la coupure. Pour un chargeur double aliment\u00e9 par une seule source, rep\u00e9rez la protection contre les surintensit\u00e9s de chaque prise (article 722.533.101). V\u00e9rifiez les exigences locales en mati\u00e8re de mise \u00e0 la terre, telles que la norme BS 7671, section 722, au Royaume-Uni.<\/li>\n      <li><strong>Confirmer la gestion de charge optionnelle, l&#039;OCPP et le comptage par SKU\u00a0:<\/strong> Traitez les compteurs DLB\/LMS, OCPP et MID\/national comme des options d\u00e9pendantes du mod\u00e8le \u2014 verrouillez-les explicitement sur le devis avant de dimensionner les d\u00e9parts selon la clause 722.311 de la norme IEC 60364-7-722 (facteur de diversit\u00e9 = 1 sans contr\u00f4le de charge actif).<\/li>\n      <li><strong>Preuves d&#039;essais de produits distincts, classe CEM et acc\u00e8s au march\u00e9\u00a0:<\/strong> Demander les preuves de test IEC 61851-1 \/ IEC 62752 sp\u00e9cifiques \u00e0 l&#039;UGS, confirmer la classe B de CEM IEC 61851-21-2 pour les r\u00e9seaux r\u00e9sidentiels (par rapport \u00e0 la classe A commerciale), v\u00e9rifier la port\u00e9e de facturation MID monophas\u00e9e par rapport \u00e0 triphas\u00e9e et demander la documentation EU DoC, UKCA ou UL\/CSA du march\u00e9 de destination.<\/li>\n      <li><strong>Inspection de l&#039;installation sur site et des limites non dangereuses lors de la remise\u00a0:<\/strong> Avant la mise sous tension, v\u00e9rifiez l&#039;\u00e9tiquetage du circuit d\u00e9di\u00e9, l&#039;indice de protection IP\/IK du bo\u00eetier pour le mod\u00e8le et le raccordement exacts, l&#039;absence de rallonges de c\u00e2ble, la v\u00e9rification du d\u00e9gagement en zone non dangereuse et les enregistrements des tests de continuit\u00e9 de la terre\/RCD fonctionnels.<\/li>\n    <\/ol>\n  <\/div>\n\n  <div class=\"evb-callout\">\n    <h3>Sp\u00e9cifier un chargeur secteur portable de mode 2 ou un chargeur secteur commercial de mode 3\u00a0?<\/h3>\n    <p>Partagez votre march\u00e9 cible (UE\/AFIR, Royaume-Uni, APAC ou Am\u00e9rique du Nord), votre alimentation CA (230 V monophas\u00e9 ou 400 V triphas\u00e9), le nombre de baies, la consommation quotidienne en kWh par v\u00e9hicule et les exigences optionnelles OCPP\/DLB\/MID avec l&#039;\u00e9quipe d&#039;ing\u00e9nierie d&#039;EVB pour confirmer les sch\u00e9mas de c\u00e2blage exacts des SKU et la coordination de la protection en amont.<\/p>\n    <a class=\"evb-cta-btn\" href=\"https:\/\/www.evb.com\/fr\/personnalisation-du-chargeur-ve\/\">Demande de sp\u00e9cifications et de personnalisation du chargeur EVB<\/a>\n  <\/div>\n\n  <h2 id=\"frequently-asked-questions\">7. Foire aux questions<\/h2>\n\n  <h3 id=\"faq-mode-2-daily-charging\">Puis-je utiliser un chargeur portable de mode 2 (\u00ab \u00e0 3 broches \u00bb ou \u00ab grand-m\u00e8re \u00bb) tous les jours \u00e0 la maison ?<\/h3>\n  <p>Un dispositif de protection contre les surintensit\u00e9s de type 2 (IC-CPD) conforme \u00e0 la norme IEC 62752 est con\u00e7u pour une recharge portable et occasionnelle en toute s\u00e9curit\u00e9, et non comme une solution de remplacement \u00e0 long terme pour une borne de recharge murale de type 3 install\u00e9e sur une prise domestique standard. L&#039;intensit\u00e9 nominale d&#039;une prise domestique ne garantissant pas \u00e0 elle seule son aptitude \u00e0 supporter une charge quotidienne prolong\u00e9e pour un v\u00e9hicule \u00e9lectrique, il est recommand\u00e9 de suivre les recommandations locales (par exemple, la r\u00e9glementation danoise exige une prise con\u00e7ue pour supporter des charges \u00e9lev\u00e9es et soutenues si la dur\u00e9e de la recharge d\u00e9passe deux heures), d&#039;utiliser une prise domestique homologu\u00e9e pour v\u00e9hicules \u00e9lectriques sur un circuit d\u00e9di\u00e9 avec un cordon compatible (tel que la norme britannique BS 1363-2\/EV ou la norme fran\u00e7aise Green&#039;Up, le cas \u00e9ch\u00e9ant), ou \u2013 solution optimale pour une recharge quotidienne r\u00e9guli\u00e8re \u2013 d&#039;installer une borne de recharge murale de type 3 d\u00e9di\u00e9e, v\u00e9rifi\u00e9e par un \u00e9lectricien qualifi\u00e9.<\/p>\n\n  <h3 id=\"faq-mode-2-cee-22kw\">Un chargeur de mode 2 peut-il fournir 11 kW ou 22 kW via une prise CEE industrielle\u00a0?<\/h3>\n  <p>Oui, la norme IEC 61851-1 autorise le mode 2 jusqu&#039;\u00e0 <strong>32 A \u00e0 250 V CA (monophas\u00e9) ou 480 V CA (triphas\u00e9)<\/strong>La puissance de sortie d\u00e9pend de la prise CEE sp\u00e9cifique, du nombre de phases et de la capacit\u00e9 du circuit\u00a0: sur <strong>triphas\u00e9 400 V<\/strong>, <strong>16 A d\u00e9livrent environ 11 kW<\/strong> et <strong>32 A d\u00e9livrent environ 22 kW<\/strong>; sur <strong>230 V monophas\u00e9<\/strong>, <strong>16 A d\u00e9livrent ~3,7 kW<\/strong> et <strong>32 A d\u00e9livrent environ 7,4 kW<\/strong> (Comme propos\u00e9 sur la gamme de chargeurs portables 2-en-1 7,4 kW \/ 22 kW d&#039;EVB), la puissance maximale est toujours celle de l&#039;alimentation du site, de la prise\/du cordon d&#039;alimentation, du chargeur portable et du chargeur embarqu\u00e9 du v\u00e9hicule. La prise CEE industrielle doit \u00eatre raccord\u00e9e \u00e0 un circuit d\u00e9di\u00e9 conforme \u00e0 la norme IEC 60364-7-722 avec protection diff\u00e9rentielle\/contre-intensit\u00e9 en amont v\u00e9rifi\u00e9e. Il convient de se renseigner sur la r\u00e9glementation nationale avant d&#039;utiliser le mode 2 CEE pour la recharge permanente sur un lieu de travail ou dans un espace public.<\/p>\n\n  <h3 id=\"faq-mode-3-type-a-vs-type-b-rcd\">Un chargeur de mode 3 avec capteur CC int\u00e9gr\u00e9 de 6 mA a-t-il toujours besoin d&#039;un disjoncteur diff\u00e9rentiel de type B\u00a0?<\/h3>\n  <p>Sous <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">CEI 60364-7-722:2018<\/a>, chaque point de connexion Mode 3 prot\u00e9g\u00e9 par d\u00e9connexion automatique n\u00e9cessite soit un <strong>DDR de type B de 30 mA<\/strong> <em>ou<\/em> un <strong>DDR de type A (ou de type F) de 30 mA associ\u00e9 \u00e0 un <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32963\" rel=\"nofollow\">CEI 62955<\/a> 6 mA CC RDC-DD<\/strong> (Sauf si la s\u00e9paration \u00e9lectrique pr\u00e9vue \u00e0 l&#039;article 722.413, via un transformateur d&#039;isolement IEC 61558-2-4, alimente un seul v\u00e9hicule \u00e9lectrique). Consultez le sch\u00e9ma de c\u00e2blage et les instructions d&#039;installation du mod\u00e8le pour identifier les dispositifs de d\u00e9tection et de d\u00e9connexion, puis s\u00e9lectionnez le disjoncteur diff\u00e9rentiel en amont adapt\u00e9 au site, conform\u00e9ment \u00e0 la r\u00e9glementation nationale applicable.<\/p>\n\n  <h3 id=\"faq-mode-vs-type-and-level\">Quelle est la diff\u00e9rence entre les modes 2\/3, type 1\/2 et la charge rapide CA niveau 1\/niveau 2\/CC\u00a0?<\/h3>\n  <p><strong>Modes 1 \u00e0 4<\/strong> (IEC 61851-1) d\u00e9crit l&#039;architecture de charge et l&#039;emplacement des commandes\/protections. <strong>Type 1 et type 2<\/strong> (IEC 62196-2) d\u00e9crit la g\u00e9om\u00e9trie physique des connecteurs CA \u2014 les c\u00e2bles de mode 2 et les stations de mode 3 utilisent couramment des connecteurs de type 2 en Europe et sur les march\u00e9s mondiaux de la CEI. <strong>Charge rapide CA niveau 1, CA niveau 2 et CC<\/strong> (parfois appel\u00e9s famili\u00e8rement \u00ab niveau 3 \u00bb) sont des classifications nord-am\u00e9ricaines utilis\u00e9es en parall\u00e8le <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2594\" rel=\"nofollow\">ANSI\/UL 2594<\/a> (pour les bornes de recharge pour v\u00e9hicules \u00e9lectriques CA) plut\u00f4t que les modes CEI.<\/p>\n\n  <h3 id=\"faq-extension-cord-ev-charging\">Pourquoi les rallonges \u00e9lectriques sont-elles interdites avec les c\u00e2bles de charge de mode 2 et de mode 3\u00a0?<\/h3>\n  <p>Les rallonges \u00e9lectriques standard augmentent la r\u00e9sistance de contact non contr\u00f4l\u00e9e, ne disposent pas de capteur thermique au niveau de la jonction fiche-prise, peuvent surchauffer fortement lorsqu&#039;elles sont enroul\u00e9es sous charge \u00e9lectrique continue et peuvent compromettre la continuit\u00e9 de la mise \u00e0 la terre ou l&#039;\u00e9tanch\u00e9it\u00e9 IP. Les recommandations d&#039;installation IEC et les manuels officiels de l&#039;EVB interdisent formellement l&#039;utilisation de rallonges\u00a0; il est recommand\u00e9 de commander un c\u00e2ble homologu\u00e9 par le fabricant et suffisamment long pour atteindre la prise du v\u00e9hicule, ou de d\u00e9placer le bo\u00eetier Mode 3 fixe.<\/p>\n\n  <h2 id=\"references\">8. Normes primaires et r\u00e9f\u00e9rences techniques<\/h2>\n  <ul>\n    <li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/33644\" rel=\"nofollow\">CEI 61851-1:2017 (\u00c9dition 3.0)<\/a> \u2014 Syst\u00e8me de charge conductrice pour v\u00e9hicules \u00e9lectriques, Partie 1 : Exigences g\u00e9n\u00e9rales (publi\u00e9 le 7 f\u00e9vrier 2017 ; consult\u00e9 le 21 novembre 2026).<\/li>\n    <li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/66220\" rel=\"nofollow\">CEI 62752:2024 (\u00c9dition 2.0)<\/a> \u2014 Dispositif de commande et de protection int\u00e9gr\u00e9 au c\u00e2ble (IC-CPD) pour la charge en mode 2 des v\u00e9hicules routiers \u00e9lectriques (publi\u00e9 le 27 mars 2024 ; sous-clauses 8.3.1 et 9.36 ; consult\u00e9 le 21 novembre 2026).<\/li>\n    <li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">CEI 60364-7-722:2018 (\u00c9dition 2.0)<\/a> (Articles 722.311, 722.312.2.1, 722.314.101, 722.411.3.3, 722.413, 722.531.2.101, 722.533.101) et <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32963\" rel=\"nofollow\">CEI 62955:2018 (\u00c9dition 1.0)<\/a> (RDC-DD pour le mode 3 ; consult\u00e9 le 21 novembre 2026).<\/li>\n    <li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32973\" rel=\"nofollow\">CEI 61851-23:2023 (\u00c9dition 2.0)<\/a> \u2014 \u00c9quipements d&#039;alimentation pour v\u00e9hicules \u00e9lectriques CC (stations CC externes \u00e0 entr\u00e9e CA et CC ; publi\u00e9 le 13 d\u00e9cembre 2023 ; consult\u00e9 le 21 novembre 2026).<\/li>\n    <li><a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2023\/1804\/2026-01-08\/eng\" rel=\"nofollow\">EUR-Lex \u2014 R\u00e8glement (UE) 2023\/1804 (AFIR, consolid\u00e9 le 8 janvier 2026)<\/a> (Annexe II \u00a71.1 Mode 2 \u22643,7 kW Exception IEC 60884-1:2022 et article 5(1) points publics payants) et <a href=\"https:\/\/www.gov.uk\/government\/publications\/the-public-charge-point-regulations-2023-guidance\/public-charge-point-regulations-2023-guidance\" rel=\"nofollow\">Gouvernement britannique \u2014 Guide relatif \u00e0 la r\u00e9glementation de 2023 sur les bornes de recharge publiques<\/a> (consult\u00e9 le 21 novembre 2026).<\/li>\n    <li><a href=\"https:\/\/www.electrical-installation.org\/enwiki\/Electric_Vehicle_and_EV_charging_fundamentals\" rel=\"nofollow\">Guide d&#039;installation \u00e9lectrique de Schneider Electric \u2014 Principes fondamentaux des v\u00e9hicules \u00e9lectriques<\/a>, <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/EV_charging_station_design\" rel=\"nofollow\">Conception de la gare<\/a>, et <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/EV_charging_-_electrical_installation_design\" rel=\"nofollow\">Conception d&#039;installations \u00e9lectriques<\/a>; <a href=\"https:\/\/electrical.theiet.org\/bs-7671-18th-edition-wiring-regulations\/ensure-you-are-up-to-date-with-bs-7671\" rel=\"nofollow\">IET \u2014 BS 7671 18e \u00e9dition R\u00e8glementation sur les c\u00e2blages<\/a> &amp; <a href=\"https:\/\/electrical.theiet.org\/wiring-matters\/years\/2019\/76-july-2019\/latest-developments-in-international-standards-for-supplies-for-electric-vehicles\/\" rel=\"nofollow\">L&#039;importance du c\u00e2blage IET \u2014 Normes internationales pour les alimentations des v\u00e9hicules \u00e9lectriques<\/a>; <a href=\"https:\/\/www.sik.dk\/erhverv\/elinstallationer-og-elanlaeg\/vejledninger\/elinstallationer\/elbiler\/oplad-din-el-bil-sikkert\" rel=\"nofollow\">Autorit\u00e9 danoise des technologies de s\u00e9curit\u00e9 (Sikkerhedsstyrelsen) \u2014 Guide de recharge s\u00fbre des v\u00e9hicules \u00e9lectriques<\/a>; <a href=\"https:\/\/www.legrand.fr\/pro\/solutions\/prises-et-bornes-de-recharge-pour-vehicules-electriques-ensemble-vers-plus-de-mobilite-verte\" rel=\"nofollow\">Legrand \u2014 Documentation sur la prise Green&#039;Up pour v\u00e9hicules \u00e9lectriques<\/a>; et <a href=\"https:\/\/www.press.renault.co.uk\/releases\/502\" rel=\"nofollow\">Communiqu\u00e9 de presse Renault Royaume-Uni \u2014 Recharge CA ZOE 43 kW<\/a> (consult\u00e9 le 21 novembre 2026).<\/li>\n    <li><a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2594\" rel=\"nofollow\">ANSI\/UL 2594 (\u00e9d. 3, 2022-12-15)<\/a>, <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2231-1\" rel=\"nofollow\">ANSI\/UL 2231-1 (\u00e9d. 3, 2026-11-06)<\/a>, <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2231-2\" rel=\"nofollow\">UL 2231-2 (r\u00e9v. 2020-12-15)<\/a>, <a href=\"https:\/\/driveelectric.gov\/charging-connector\" rel=\"nofollow\">Bureau conjoint de l&#039;\u00e9nergie et des transports \u2014 Connecteur SAE J3400<\/a>, et <a href=\"https:\/\/afdc.energy.gov\/fuels\/electricity-stations\" rel=\"nofollow\">Programme AFDC du D\u00e9partement de l&#039;\u00c9nergie des \u00c9tats-Unis \u2014 D\u00e9veloppement des infrastructures de recharge pour v\u00e9hicules \u00e9lectriques<\/a> (consult\u00e9 le 21 novembre 2026).<\/li>\n    <li><a href=\"https:\/\/media.mennekes.org\/1367402_en_53674_originaldatei.pdf\" rel=\"nofollow\">Fiche technique Mennekes AMTRON Professional+ PnC 22<\/a> \u2014 voir les sp\u00e9cifications de comptage pour la configuration triphas\u00e9e MID (consult\u00e9es le 21 novembre 2026).<\/li>\n    <li><a href=\"https:\/\/www.evb.com\/fr\/guides-videos\/\">Fiches techniques des \u00e9quipements EVB<\/a> pour le <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-Unsmart-Portable-AC-EV-Charger-2025.08.13.pdf\">BCPP-A1-16<\/a>, <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-Smart-Portable-Wall-mounted-AC-EV-Charger-2024.09.06.pdf\">chargeurs portables intelligents<\/a>, <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Wall-mounted-AC-EV-Charger-2024.09.06.pdf\">bo\u00eetiers muraux de premi\u00e8re g\u00e9n\u00e9ration<\/a>, <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-2nd-Generation-OCPP-Wall-mounted-AC-EV-Charger-2025.11.04.pdf\">bo\u00eetiers muraux de deuxi\u00e8me g\u00e9n\u00e9ration<\/a>, <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Wall-mounted-Dual-Cable-AC-EV-Charger-Metal-Enclosure-2025.04.07.pdf\">Bo\u00eetier mural \u00e0 double c\u00e2ble BCPCM<\/a> et <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Floor-mounted-AC-EV-Charger-2025.07.11.pdf\">Socle BCPCV s\u00e9rie N<\/a>Voir le <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2024\/02\/Floor-Mounted-AC-EV-Charger-0228.pdf\">Manuel d&#039;installation BCPCV<\/a> pour l&#039;installation \u00e0 double entr\u00e9e illustr\u00e9e.<\/li>\n  <\/ul>\n<\/div>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>EVB.COM &middot; Author: EVB Charging Solutions Team &middot; Updated November 2026 &middot; 18-minute read &middot; EV Charging Modes &middot; IEC 61851 &middot; AC &amp; DC Charging Mode 2 and Mode 3 both charge an EV with AC power. On a portable Mode 2 cable, the small box between the wall plug and the car is [&hellip;]<\/p>","protected":false},"author":3,"featured_media":42369,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[26],"tags":[486,484,485],"class_list":["post-44823","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-ac-ev-charging","tag-ev-charging-modes","tag-iec-61851"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB<\/title>\n<meta name=\"description\" content=\"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.evb.com\/fr\/mode-2-vs-mode-3-ev-charging\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB\" \/>\n<meta property=\"og:description\" content=\"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.evb.com\/fr\/mode-2-vs-mode-3-ev-charging\/\" \/>\n<meta property=\"og:site_name\" content=\"EVB\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-21T08:49:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-21T08:49:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"720\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"EVB Editorial Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"\u00c9crit par\" \/>\n\t<meta name=\"twitter:data1\" content=\"EVB Editorial Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data2\" content=\"22 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/\"},\"author\":{\"name\":\"EVB Editorial Team\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/person\\\/fe8f0137976034abdfd2ae4f8c5682d0\"},\"headline\":\"Mode 2 vs Mode 3 EV Charging: When to Use a Portable Charger or Wallbox\",\"datePublished\":\"2026-11-21T08:49:33+00:00\",\"dateModified\":\"2026-11-21T08:49:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/\"},\"wordCount\":4388,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/EVB-MODE-3-AC-EV-charger.webp\",\"keywords\":[\"AC EV Charging\",\"EV Charging Modes\",\"IEC 61851\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/\",\"url\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/\",\"name\":\"Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/EVB-MODE-3-AC-EV-charger.webp\",\"datePublished\":\"2026-11-21T08:49:33+00:00\",\"dateModified\":\"2026-11-21T08:49:45+00:00\",\"description\":\"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/EVB-MODE-3-AC-EV-charger.webp\",\"contentUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/EVB-MODE-3-AC-EV-charger.webp\",\"width\":720,\"height\":720,\"caption\":\"EVB MODE 3 AC EV charger\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.evb.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Mode 2 vs Mode 3 EV Charging: When to Use a Portable Charger or Wallbox\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#website\",\"url\":\"https:\\\/\\\/www.evb.com\\\/\",\"name\":\"EVB\",\"description\":\"Smart EV Charging &amp; Energy Storage Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.evb.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\",\"name\":\"EVB\",\"url\":\"https:\\\/\\\/www.evb.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/evb-3.png\",\"contentUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/evb-3.png\",\"width\":605,\"height\":626,\"caption\":\"EVB\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/person\\\/fe8f0137976034abdfd2ae4f8c5682d0\",\"name\":\"EVB Editorial Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"caption\":\"EVB Editorial Team\"},\"description\":\"The EVB Editorial Team creates expert content on EV charging infrastructure, commercial charging solutions, energy storage integration, and global charging projects, with input from EVB product and engineering specialists.\",\"sameAs\":[\"https:\\\/\\\/www.evb.com\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB","description":"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.evb.com\/fr\/mode-2-vs-mode-3-ev-charging\/","og_locale":"fr_FR","og_type":"article","og_title":"Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB","og_description":"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.","og_url":"https:\/\/www.evb.com\/fr\/mode-2-vs-mode-3-ev-charging\/","og_site_name":"EVB","article_published_time":"2026-11-21T08:49:33+00:00","article_modified_time":"2026-11-21T08:49:45+00:00","og_image":[{"width":720,"height":720,"url":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp","type":"image\/webp"}],"author":"EVB Editorial Team","twitter_card":"summary_large_image","twitter_misc":{"\u00c9crit par":"EVB Editorial Team","Dur\u00e9e de lecture estim\u00e9e":"22 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#article","isPartOf":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/"},"author":{"name":"EVB Editorial Team","@id":"https:\/\/www.evb.com\/#\/schema\/person\/fe8f0137976034abdfd2ae4f8c5682d0"},"headline":"Mode 2 vs Mode 3 EV Charging: When to Use a Portable Charger or Wallbox","datePublished":"2026-11-21T08:49:33+00:00","dateModified":"2026-11-21T08:49:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/"},"wordCount":4388,"commentCount":0,"publisher":{"@id":"https:\/\/www.evb.com\/#organization"},"image":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#primaryimage"},"thumbnailUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp","keywords":["AC EV Charging","EV Charging Modes","IEC 61851"],"articleSection":["Blog"],"inLanguage":"fr-FR","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/","url":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/","name":"Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB","isPartOf":{"@id":"https:\/\/www.evb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#primaryimage"},"image":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#primaryimage"},"thumbnailUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp","datePublished":"2026-11-21T08:49:33+00:00","dateModified":"2026-11-21T08:49:45+00:00","description":"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.","breadcrumb":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#primaryimage","url":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp","contentUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp","width":720,"height":720,"caption":"EVB MODE 3 AC EV charger"},{"@type":"BreadcrumbList","@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.evb.com\/"},{"@type":"ListItem","position":2,"name":"Mode 2 vs Mode 3 EV Charging: When to Use a Portable Charger or Wallbox"}]},{"@type":"WebSite","@id":"https:\/\/www.evb.com\/#website","url":"https:\/\/www.evb.com\/","name":"EVB","description":"Smart EV Charging &amp; Energy Storage Solutions","publisher":{"@id":"https:\/\/www.evb.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.evb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"},{"@type":"Organization","@id":"https:\/\/www.evb.com\/#organization","name":"EVB","url":"https:\/\/www.evb.com\/","logo":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/www.evb.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.evb.com\/wp-content\/uploads\/2021\/03\/evb-3.png","contentUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2021\/03\/evb-3.png","width":605,"height":626,"caption":"EVB"},"image":{"@id":"https:\/\/www.evb.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.evb.com\/#\/schema\/person\/fe8f0137976034abdfd2ae4f8c5682d0","name":"EVB Editorial Team","image":{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","caption":"EVB Editorial Team"},"description":"The EVB Editorial Team creates expert content on EV charging infrastructure, commercial charging solutions, energy storage integration, and global charging projects, with input from EVB product and engineering specialists.","sameAs":["https:\/\/www.evb.com\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.evb.com\/fr\/wp-json\/wp\/v2\/posts\/44823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.evb.com\/fr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.evb.com\/fr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.evb.com\/fr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.evb.com\/fr\/wp-json\/wp\/v2\/comments?post=44823"}],"version-history":[{"count":2,"href":"https:\/\/www.evb.com\/fr\/wp-json\/wp\/v2\/posts\/44823\/revisions"}],"predecessor-version":[{"id":44827,"href":"https:\/\/www.evb.com\/fr\/wp-json\/wp\/v2\/posts\/44823\/revisions\/44827"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.evb.com\/fr\/wp-json\/wp\/v2\/media\/42369"}],"wp:attachment":[{"href":"https:\/\/www.evb.com\/fr\/wp-json\/wp\/v2\/media?parent=44823"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.evb.com\/fr\/wp-json\/wp\/v2\/categories?post=44823"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.evb.com\/fr\/wp-json\/wp\/v2\/tags?post=44823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}