{"id":44823,"date":"2026-11-21T16:49:33","date_gmt":"2026-11-21T08:49:33","guid":{"rendered":"https:\/\/www.evb.com\/?p=44823"},"modified":"2026-11-21T16:49:45","modified_gmt":"2026-11-21T08:49:45","slug":"mode-2-vs-mode-3-ev-charging","status":"publish","type":"post","link":"https:\/\/www.evb.com\/pl\/mode-2-vs-mode-3-ev-charging\/","title":{"rendered":"\u0141adowanie pojazd\u00f3w elektrycznych w trybie 2 a w trybie 3: kiedy u\u017cywa\u0107 \u0142adowarki przeno\u015bnej lub \u015bciennej"},"content":{"rendered":"<style>\n.evb-modes-article{font-family:inherit;color:#1f1f1f;font-size:17px;line-height:1.8;overflow-wrap:break-word}\n.evb-modes-article h2,.evb-modes-article h3{color:#0b2239;line-height:1.3}\n.evb-modes-article h2{font-size:30px;font-weight:800;margin:44px 0 14px}\n.evb-modes-article h3{font-size:22px;font-weight:700;margin:26px 0 10px}\n.evb-modes-article p{margin:0 0 18px;color:#3f4852}\n.evb-modes-article a{color:#185fa5;text-decoration:underline;text-underline-offset:2px}\n.evb-modes-article a:focus-visible,.evb-modes-article .evb-table-wrap:focus-visible{outline:2px solid #185fa5;outline-offset:3px}\n.evb-modes-article .evb-eeat-line{margin:0 0 26px;color:#667584;font-size:15px;line-height:1.7}\n.evb-modes-article .evb-article-intro{border-left:4px solid #185fa5;background:#f4f8fc;padding:16px 20px;border-radius:0 8px 8px 0;margin:0 0 24px;font-size:17.5px;line-height:1.72;color:#172b3e}\n.evb-modes-article .evb-example-box{background:#f0f7fb;border:1px solid #cce0ee;border-radius:8px;padding:15px 18px;margin:0 0 22px;font-size:16px;color:#163146}\n.evb-modes-article ul,.evb-modes-article ol{margin:0 0 18px 22px;padding:0}\n.evb-modes-article li{margin:0 0 9px;color:#3f4852}\n.evb-modes-article .evb-table-title{margin:20px 0 8px;color:#0b2239;font-weight:700;font-size:15.5px;line-height:1.45}\n.evb-modes-article .evb-table-wrap{max-width:100%;overflow-x:auto;margin:0 0 12px;-webkit-overflow-scrolling:touch}\n.evb-modes-article .evb-table{width:100%;min-width:600px;border-collapse:collapse;font-size:15px}\n.evb-modes-article .evb-table th,.evb-modes-article .evb-table td{border:1px solid #dfe6ed;padding:11px 13px;text-align:left;vertical-align:top}\n.evb-modes-article .evb-table thead th{background:#0b2239;color:#fff;font-size:13.5px;letter-spacing:.02em}\n.evb-modes-article .evb-table tbody th{background:#f7fafe;color:#0b2239;font-weight:700}\n.evb-modes-article .evb-table tbody tr:nth-child(even) td{background:#fafcfe}\n.evb-modes-article .evb-table-note{font-size:13px;color:#526171;margin:0 0 24px}\n.evb-modes-article .evb-checklist{background:#f7f9fc;border:1px solid #d9e3ee;border-radius:8px;padding:18px 22px;margin:22px 0 26px}\n.evb-modes-article .evb-checklist h3,.evb-modes-article .evb-callout h3{margin-top:0}\n.evb-modes-article .evb-checklist>:last-child,.evb-modes-article .evb-callout>:last-child{margin-bottom:0}\n.evb-modes-article .evb-callout{background:#0b2239;color:#fff;border-radius:10px;padding:24px 26px;margin:32px 0}\n.evb-modes-article .evb-callout h3,.evb-modes-article .evb-callout p{color:#f1f6fb}\n.evb-modes-article .evb-callout a{color:#9fd4ff;font-weight:600}\n.evb-modes-article .evb-cta-btn{display:inline-block;margin-top:8px;background:#185fa5;color:#fff!important;text-decoration:none!important;padding:11px 22px;border-radius:7px;font-weight:700}\n.evb-modes-article .evb-cta-btn:hover{background:#124c85}\n.evb-modes-article .evb-article-figure{max-width:920px;margin:24px 0 28px}\n.evb-modes-article .evb-article-figure a{display:block}\n.evb-modes-article .evb-article-figure img{display:block;width:100%;height:auto;border-radius:10px;border:1px solid #dce5ee}\n.evb-modes-article figcaption{margin-top:9px;color:#526171;font-size:.88em;line-height:1.55}\n@media(max-width:768px){\n  .evb-modes-article{font-size:16px}\n  .evb-modes-article h2{font-size:24px;margin:34px 0 12px}\n  .evb-modes-article h3{font-size:19px}\n}\n<\/style>\n<div class=\"evb-article-wrap evb-modes-article\" lang=\"en\">\n  <div class=\"evb-eeat-line\">EVB.COM \u00b7 Autor: Zesp\u00f3\u0142 EVB Charging Solutions \u00b7 Aktualizacja: listopad 2026 \u00b7 Czas czytania: 18 minut \u00b7 Tryby \u0142adowania pojazd\u00f3w elektrycznych \u00b7 IEC 61851 \u00b7 \u0141adowanie pr\u0105dem przemiennym i sta\u0142ym<\/div>\n\n  <p class=\"evb-article-intro\"><strong>Zar\u00f3wno tryb 2, jak i tryb 3 \u0142aduj\u0105 pojazd elektryczny za pomoc\u0105 pr\u0105du zmiennego.<\/strong> W przeno\u015bnym kablu Mode 2, ma\u0142a skrzynka mi\u0119dzy wtyczk\u0105 \u015bcienn\u0105 a samochodem nazywana jest wbudowanym w kabel urz\u0105dzeniem steruj\u0105cym i zabezpieczaj\u0105cym (IC-CPD). Czeka ono na gotowo\u015b\u0107 samochodu przed w\u0142\u0105czeniem zasilania. Je\u015bli wykryje nadmierny pr\u0105d up\u0142ywowy podczas \u0142adowania, odcina zasilanie. Wallbox Mode 3 lub podstawa odpowiada za kontrol\u0119 \u0142adowania na stacji i wykorzystuje dedykowany obw\u00f3d zasilania. Tryb 2 jest przydatny do okazjonalnego \u0142adowania z odpowiedniego gniazdka. Do codziennego \u0142adowania w sta\u0142ym miejscu, wybierz Tryb 3.<\/p>\n\n  <p>Przed por\u00f3wnaniem standard\u00f3w kupuj\u0105cy i plani\u015bci zazwyczaj decyduj\u0105 si\u0119 na jeden z trzech praktycznych zestaw\u00f3w sprz\u0119tu klimatyzacyjnego:<\/p>\n  <ul>\n    <li><strong>Przeno\u015bny kabel trybu 2.<\/strong> Pod\u0142\u0105cza si\u0119 go do odpowiedniego gniazdka domowego, elektrycznego lub przemys\u0142owego. Zgodnie z normami IEC 61851-1 i IEC 62752, limit pr\u0105du w trybie 2 wynosi 32 A. Gniazdo, obw\u00f3d i kabel mog\u0105 narzuca\u0107 dolny limit.<\/li>\n    <li><strong>Tryb 3 z gniazdem i osobnym kablem (przypadek B).<\/strong> U\u017cyj kompatybilnego kabla, najlepiej takiego, kt\u00f3ry masz w samochodzie. Pod\u0142\u0105cz jeden koniec do gniazda stacji (na przyk\u0142ad typu 2), a drugi do gniazda w samochodzie. Po na\u0142adowaniu od\u0142\u0105cz oba ko\u0144ce i zabierz kabel ze sob\u0105.<\/li>\n    <li><strong>Tryb 3 z kablem przymocowanym do stacji (przypadek C).<\/strong> Podnie\u015b z\u0142\u0105cze kabla stacji i pod\u0142\u0105cz je do samochodu. Po zako\u0144czeniu od\u0142\u0105cz je od samochodu i od\u0142\u00f3\u017c z powrotem do uchwytu. Kabel pozostaje przy stacji.<\/li>\n  <\/ul>\n\n  <div class=\"evb-example-box\"><strong>Przyk\u0142ad szybkiego wymiarowania \u2014 sprawd\u017a wszystkie cztery sufity jednocze\u015bnie:<\/strong> Rzeczywista pr\u0119dko\u015b\u0107 \u0142adowania pr\u0105dem przemiennym jest ograniczona przez najni\u017cszy limit spo\u015br\u00f3d <em>dostawa na miejscu<\/em>, <em>rumak<\/em>, <em>kabel<\/em>, I <em>\u0142adowarka pok\u0142adowa pojazdu (OBC)<\/em>Na przyk\u0142ad, je\u015bli samoch\u00f3d akceptuje maksymalnie <strong>11 kW<\/strong> pr\u0105d zmienny tr\u00f3jfazowy i pod\u0142\u0105cza si\u0119 do <strong>22 kW<\/strong> wallbox (z odpowiednim zasilaniem i parametrami kabla), pojazd nadal pobiera maksymalnie oko\u0142o <strong>11 kW<\/strong>. Wymiana <strong>22 kWh<\/strong> dziennej energii potrzebnej do jazdy samochodem zajmuje oko\u0142o <strong>9,6 godziny<\/strong> na obwodzie trybu 2 zweryfikowanym pod k\u0105tem <strong>230 V, 10 A (2,3 kW)<\/strong> ci\u0105g\u0142e \u0142adowanie, w por\u00f3wnaniu z oko\u0142o <strong>2 godziny<\/strong> w trybie 3 o <strong>11 kW<\/strong> (pomijaj\u0105c straty konwersji) \u2014 dzi\u0119ki czemu tryb 3 pr\u0105du przemiennego wystarcza na noc lub do pracy, bez konieczno\u015bci szybkiego \u0142adowania pr\u0105dem sta\u0142ym.<\/div>\n\n  <p>EVB-y <a href=\"https:\/\/www.evb.com\/pl\/ev-charge-cables\/\">Przewodnik po kablach do \u0142adowania pojazd\u00f3w elektrycznych<\/a> ju\u017c przechodzi przez cztery tryby \u0142adowania na wysokim poziomie, podczas gdy <a href=\"https:\/\/www.evb.com\/pl\/tethered-vs-untethered-ev-charger\/\">\u0142adowarki EV pod\u0142\u0105czone i niepod\u0142\u0105czone<\/a> por\u00f3wnuje przypadek C z przypadkiem B i <a href=\"https:\/\/www.evb.com\/pl\/ev-charging-levels\/\">Poziomy \u0142adowania pojazd\u00f3w elektrycznych<\/a> obejmuje poziomy p\u00f3\u0142nocnoameryka\u0144skie. Ten przewodnik koncentruje si\u0119 na <strong>wyb\u00f3r pola pomi\u0119dzy trybem 2 i trybem 3<\/strong>, dok\u0142adny <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">IEC 60364-7-722:2018<\/a> &amp; granice zgodno\u015bci z normami AFIR UE oraz konfiguracje \u0142adowarek EVB.<\/p>\n\n  <h2 id=\"when-to-choose-mode-2-mode-3-or-mode-4\">1. Macierz wyboru p\u00f3l trybu 2 i trybu 3 (kiedy u\u017cywa\u0107 ka\u017cdego)<\/h2>\n\n  <p>Zacznij od podania trzech danych wej\u015bciowych dotycz\u0105cych witryny:<strong>ile kWh dziennie musz\u0105 uzupe\u0142nia\u0107 pojazdy<\/strong>, <strong>jak d\u0142ugo pozostaj\u0105 zaparkowani<\/strong>, I <strong>czy gniazdo lub panel rozdzielczy s\u0105 sprawdzone pod k\u0105tem ci\u0105g\u0142ego obci\u0105\u017cenia pojazdu elektrycznego<\/strong>:<\/p>\n\n  <figure class=\"evb-article-figure\">\n    <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/iec-61851-charging-modes-1-2-3-4-architecture.webp\" target=\"_blank\" rel=\"noopener\" title=\"Otw\u00f3rz schemat \u015bcie\u017cki \u0142adowania pr\u0105dem przemiennym IEC 61851-1 w pe\u0142nej rozdzielczo\u015bci, tryb 2 i tryb 3\">\n      <img src=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/iec-61851-charging-modes-1-2-3-4-architecture.webp\" alt=\"Schemat neutralny j\u0119zykowo, por\u00f3wnuj\u0105cy tryb 2 normy IEC 61851-1 (gniazdo do kabla IC-CPD do pok\u0142adowej \u0142adowarki pojazdu elektrycznego, do 32 A) i tryb 3 (obw\u00f3d chroniony norm\u0105 IEC 60364-7-722 do sta\u0142ego pr\u0105du przemiennego EVSE do pok\u0142adowej \u0142adowarki pojazdu elektrycznego, zwykle od 3,7 do 22 kW), z ikonami przypadk\u00f3w po\u0142\u0105cze\u0144 B i C poni\u017cej.\" width=\"920\" height=\"500\" loading=\"lazy\" decoding=\"async\" \/>\n    <\/a>\n    <figcaption>Tryb 2 a tryb 3 \u2013 \u015bcie\u017cki \u0142adowania pr\u0105dem przemiennym zgodnie z norm\u0105 IEC 61851-1:2017. Tryb 2 umieszcza sterowanie pilotem, zabezpieczenie przed up\u0142ywami i prze\u0142\u0105czanie przeka\u017anik\u00f3w wewn\u0105trz przeno\u015bnego uk\u0142adu scalonego IEC 62752 IC-CPD (maks. \u226432 A przy \u2264250 V 1P lub \u2264480 V 3P, z zastrze\u017ceniem ogranicze\u0144 gniazdka; norma IEC 62752:2024 wymaga pomiaru temperatury na przewodz\u0105cych pr\u0105d elementach wtyczek domowych). Tryb 3 przenosi sterowanie i prze\u0142\u0105czanie stycznik\u00f3w do sta\u0142ego uk\u0142adu \u0142adowania pr\u0105dem przemiennym (EVSE) w obwodzie zabezpieczonym zgodnie z norm\u0105 IEC 60364-7-722 (*zwykle 3,7\u201322 kW przy 16 A\/32 A; ~43,5 kW w okre\u015blonych konfiguracjach 3-fazowych 400 V i 63 A; zarz\u0105dzanie obci\u0105\u017ceniem, OCPP i liczniki MID s\u0105 opcjami zale\u017cnymi od modelu). Dolne ikony pokazuj\u0105 przypadek B (od\u0142\u0105czany kabel) i przypadek C (\u0142adowarka pod\u0142\u0105czona). Dotknij lub kliknij, aby wy\u015bwietli\u0107 w pe\u0142nej rozdzielczo\u015bci.<\/figcaption>\n  <\/figure>\n\n  <p class=\"evb-table-title\" id=\"tbl-selection-title\">Globalna macierz wyboru trybu \u0142adowania pojazd\u00f3w elektrycznych wed\u0142ug lokalizacji i warunk\u00f3w pracy<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-selection-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">Scenariusz lokalizacji i dzia\u0142ania<\/th>\n          <th scope=\"col\">Zalecany tryb uruchamiania<\/th>\n          <th scope=\"col\">In\u017cynieria krytyczna i kontrole zgodno\u015bci<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\">Kopia zapasowa na podr\u00f3\u017c, do\u0142adowanie dla go\u015bci lub wynajem tymczasowy bez zezwolenia na sta\u0142\u0105 instalacj\u0119<\/th>\n          <td><strong>Tryb 2<\/strong> (przeno\u015bny IC-CPD na gnie\u017adzie domowym lub przystosowanym do pojazd\u00f3w elektrycznych)<\/td>\n          <td>Potwierd\u017a zgodno\u015b\u0107 z norm\u0105 IEC 62752 (sprawd\u017a wytyczne 2024 Ed. 2.0, podpunkty 8.3.1 i 9.36 dotycz\u0105ce pomiaru temperatury na cz\u0119\u015bciach wtyczki domowej przewodz\u0105cych pr\u0105d), rozr\u00f3\u017cniaj standardowe gniazdka od gniazdek przeznaczonych do pojazd\u00f3w elektrycznych zatwierdzonych na poziomie krajowym, stosuj odpowiednie ograniczenie pr\u0105du ci\u0105g\u0142ego i nigdy nie u\u017cywaj przed\u0142u\u017caczy.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Warsztat, gara\u017c na wsi lub tymczasowy sk\u0142ad z zweryfikowanym gniazdem przemys\u0142owym CEE (16 A \/ 32 A)<\/th>\n          <td><strong>Tryb 2 (CEE)<\/strong> lub uaktualnij do <strong>Tryb 3<\/strong><\/td>\n          <td>Sprawd\u017a dedykowany obw\u00f3d zgodny z norm\u0105 IEC 60364-7-722, zabezpieczenie nadpr\u0105dowe w g\u00f3r\u0119 i zabezpieczenie r\u00f3\u017cnicowopr\u0105dowe RCD 30 mA, ci\u0105g\u0142\u0105 obci\u0105\u017calno\u015b\u0107 gniazdka CEE oraz czy lokalne przepisy wymagaj\u0105 sta\u0142ej stacji trybu 3 do sta\u0142ego \u0142adowania w miejscu pracy.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Codzienne \u0142adowanie w domu (1-fazowe 7,4 kW lub 3-fazowe 11\u201322 kW)<\/th>\n          <td><strong>Tryb 3<\/strong> (sta\u0142a skrzynka \u015bcienna, przypadek B lub przypadek C)<\/td>\n          <td>Dedykowany obw\u00f3d zgodny z norm\u0105 IEC 60364-7-722, zgodno\u015b\u0107 z klas\u0105 B EMC dla sieci domowych, sprawdzona koordynacja zwar\u0107 RCD + DC, zgodno\u015b\u0107 z krajowymi przepisami dotycz\u0105cymi uziemienia oraz opcjonalne dynamiczne r\u00f3wnowa\u017cenie obci\u0105\u017cenia (DLB) w przypadku ogranicze\u0144 g\u0142\u00f3wnego zasilania.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Miejsce pracy z wieloma stanowiskami, hotel, blok mieszkalny lub parking publiczny<\/th>\n          <td><strong>Tryb 3<\/strong> (komercyjny pr\u0105d przemienny z jednym lub dwoma wyj\u015bciami; lub wyj\u0105tek EU Mode 2 \u22643,7 kW, je\u015bli ma zastosowanie)<\/td>\n          <td>Potwierd\u017a opcjonalne LMS\/DLB, aby unikn\u0105\u0107 przewymiarowania przy wsp\u00f3\u0142czynniku r\u00f3\u017cnorodno\u015bci = 1, zweryfikuj zakres licznika rozliczeniowego OCPP i MID\/krajowego dla konkretnego SKU oraz sprawd\u017a za\u0142\u0105cznik II do rozporz\u0105dzenia AFIR UE \/ art. 5(1) lub przepisy brytyjskie dotycz\u0105ce publicznych punkt\u00f3w \u0142adowania z 2023 r.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Miejsce o du\u017cej wydajno\u015bci kWh, korytarz autostradowy lub w\u0119ze\u0142 floty, w kt\u00f3rym czas postoju nie jest w stanie pokry\u0107 dziennego zapotrzebowania na energi\u0119 na pr\u0105d przemienny<\/th>\n          <td><strong>Tryb 4<\/strong> (szybka \u0142adowarka pr\u0105du sta\u0142ego poza pok\u0142adem)<\/td>\n          <td>Oszacuj odnawialn\u0105 energi\u0119 pr\u0105du przemiennego w dost\u0119pnym czasie parkowania (dost\u0119pna moc pr\u0105du przemiennego kW \u00d7 godziny postoju, uwzgl\u0119dniaj\u0105c straty i obni\u017cenie mocy, gdzie limity mocy pr\u0105du przemiennego OBC pojazdu wynosz\u0105 zwykle 7,4\u201322 kW i do 43 kW pr\u0105du przemiennego w wybranych starszych pojazdach elektrycznych, takich jak wczesne modele Renault ZOE) i por\u00f3wnaj z wymaganymi kWh; zweryfikuj zgodno\u015b\u0107 z norm\u0105 IEC 61851-23 oraz pojemno\u015b\u0107 zasilacza\/transformatora.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Stacja paliw, sk\u0142ad chemiczny lub atmosfera potencjalnie wybuchowa<\/th>\n          <td><strong>Najpierw klasyfikacja obszar\u00f3w niebezpiecznych<\/strong> (przed wyborem trybu \u0142adowania)<\/td>\n          <td>Urz\u0105dzenia EVSE Standard Mode 2\/3\/4 s\u0105 przeznaczone wy\u0142\u0105cznie do stosowania w miejscach niezagro\u017conych wybuchem. Przed umieszczeniem \u0142adowarki w pobli\u017cu \u0142atwopalnych opar\u00f3w nale\u017cy sprawdzi\u0107 granice stref i zgodno\u015b\u0107 z normami Ex\/AHJ.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">Zawsze sprawdzaj lokalne progi powiadomie\u0144 (np. rejestracj\u0119 operatora sieci elektroenergetycznej lub operatora sieci dla \u0142adowarek stacjonarnych) oraz krajowe przepisy dotycz\u0105ce instalacji elektrycznych przed zakupem. Przesuwaj palcem poziomo na w\u0105skich ekranach.<\/p>\n\n  <h2 id=\"mode-2-vs-mode-3-safety-and-standards\">2. Bezpiecze\u0144stwo elektryczne w trybie 2 i 3: cztery granice zgodno\u015bci<\/h2>\n\n  <p>Przej\u015bcie z przeno\u015bnego zestawu przewod\u00f3w trybu 2 na stacjonarn\u0105 stacj\u0119 trybu 3 powoduje zmian\u0119 czterech odr\u0119bnych warstw zgodno\u015bci, z kt\u00f3rych ka\u017cda ma bezpo\u015bredni wp\u0142yw na rozmiar panelu, wyb\u00f3r gniazda i zatwierdzenie lokalizacji:<\/p>\n\n  <h3 id=\"layer-1-ic-cpd-and-domestic-sockets\">Warstwa 1 \u2014 tryb 2 IC-CPD i trzy odr\u0119bne poziomy gniazd (standardowe, zgodne z normami EV i przemys\u0142owe CEE)<\/h3>\n  <p>Pod <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/66220\" rel=\"nofollow\">IEC 62752:2024<\/a> (Wydanie 2.0, opublikowane 27 marca 2024 r., zast\u0119puj\u0105ce 2016 + A1:2018), uk\u0142ad scalony IC-CPD trybu 2 integruje sygnalizacj\u0119 pilota steruj\u0105cego, ci\u0105g\u0142o\u015b\u0107 uziemienia i zabezpieczenie r\u00f3\u017cnicowopr\u0105dowe, wymagania EMC zharmonizowane z <strong>IEC 61543<\/strong> I <strong>IEC 61851-21-2<\/strong>i\u2014w trakcie rewizji <strong>Podpunkt 8.3.1<\/strong> i nowe <strong>Podpunkt 9.36<\/strong>\u2014obowi\u0105zkowe urz\u0105dzenie kontroluj\u0105ce temperatur\u0119, wykrywaj\u0105ce ciep\u0142o na cz\u0119\u015bciach przewodz\u0105cych pr\u0105d wewn\u0105trz domowej wtyczki.<\/p>\n  <p>Poniewa\u017c gniazdko \u015bcienne i okablowanie odga\u0142\u0119zie\u0144 stanowi\u0105 zazwyczaj w\u0105skie gard\u0142o termiczne w \u0142adowaniu w trybie 2, nale\u017cy starannie oddzieli\u0107 trzy poziomy gniazd, zamiast traktowa\u0107 wszystkie gniazda jednakowo:<\/p>\n  <ul>\n    <li><strong>Standardowe gniazdka domowe bez znamionowego napi\u0119cia:<\/strong> Samo nat\u0119\u017cenie pr\u0105du gniazdka domowego nie gwarantuje jego przydatno\u015bci do d\u0142ugotrwa\u0142ego \u0142adowania pojazd\u00f3w elektrycznych. Nale\u017cy przestrzega\u0107 lokalnych wytycznych i sprawdzi\u0107 dozwolony pr\u0105d ci\u0105g\u0142y dla zainstalowanego gniazdka, obwodu i przewodu. Na przyk\u0142ad w Danii <a href=\"https:\/\/www.sik.dk\/erhverv\/elinstallationer-og-elanlaeg\/vejledninger\/elinstallationer\/elbiler\/oplad-din-el-bil-sikkert\" rel=\"nofollow\">w\u0142adze zalecaj\u0105 maksymalnie 6 A<\/a> do d\u0142ugotrwa\u0142ego \u0142adowania zwyk\u0142ego gniazdka domowego i wymaga dedykowanego gniazdka nadaj\u0105cego si\u0119 do d\u0142ugotrwa\u0142ego, wysokiego obci\u0105\u017cenia, je\u015bli przewiduje si\u0119, \u017ce \u0142adowanie b\u0119dzie trwa\u0142o d\u0142u\u017cej ni\u017c dwie godziny (nale\u017cy pami\u0119ta\u0107, \u017ce norma BCPP-A1-16 firmy EVB zaczyna si\u0119 od 8 A i nie mo\u017cna jej stosowa\u0107 do spe\u0142nienia limitu 6 A).<\/li>\n    <li><strong>Wzmocnione gniazdka domowe o zasi\u0119gu krajowym, dopuszczone do u\u017cytku w pojazdach elektrycznych:<\/strong> Wydzielone gniazda obwodowe zaprojektowane i przetestowane do ci\u0105g\u0142ej pracy w pojazdach elektrycznych zgodnie z przepisami krajowymi, takimi jak przepisy brytyjskie <strong>BS 1363-2\/EV<\/strong> (testowane pod obci\u0105\u017ceniem cyklicznym 13 A i oznaczone jako \u201eEV\u201d) lub gniazdka wzmocnione po francusku, takie jak <a href=\"https:\/\/www.legrand.fr\/pro\/solutions\/prises-et-bornes-de-recharge-pour-vehicules-electriques-ensemble-vers-plus-de-mobilite-verte\" rel=\"nofollow\">Legrand Green&#039;Up<\/a> (do 16 A \/ 3,7 kW w po\u0142\u0105czeniu ze zgodnym przewodem zasilaj\u0105cym, dedykowanym obwodem i warunkami instalacji NF C 15-100).<\/li>\n    <li><strong>Gniazda przemys\u0142owe CEE (IEC 60309):<\/strong> Stosowa\u0107, gdy \u0142adowanie w trybie 2 wymaga pr\u0105du o nat\u0119\u017ceniu 16 A lub 32 A (jedno- lub tr\u00f3jfazowego) poza uznanym w kraju wzmocnionym systemem gniazd domowych \u2014 wymagaj\u0105cym zweryfikowanego, dedykowanego obwodu, odpowiedniego zabezpieczenia RCD\/nadpr\u0105dowego w g\u00f3r\u0119 rzeki oraz przed\u0142u\u017caczy bezprzewodowo (co jest wyra\u017anie zabronione w instrukcjach instalacji EVB).<\/li>\n  <\/ul>\n\n  <h3 id=\"layer-2-mode-3-rcd-and-dedicated-circuit\">Warstwa 2 \u2014 dedykowane obwody pojazd\u00f3w elektrycznych, wyj\u0105tek wielopunktowy i jednowej\u015bciowy oraz koordynacja wy\u0142\u0105cznik\u00f3w r\u00f3\u017cnicowopr\u0105dowych (IEC 60364-7-722)<\/h3>\n  <p>Na poziomie okablowania budynku, <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">IEC 60364-7-722:2018<\/a> (Wydanie 2.0, opublikowane 21 wrze\u015bnia 2018 r.) reguluje <strong>wszystkie dedykowane obwody zasilania pojazd\u00f3w elektrycznych<\/strong>\u2014obejmuj\u0105c zar\u00f3wno stacje stacjonarne trybu 3, jak i dedykowane gniazda EV trybu 2. Obok <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/EV_charging_-_electrical_installation_design\" rel=\"nofollow\">Przewodnik projektowania instalacji pojazd\u00f3w elektrycznych Schneider Electric<\/a>, cztery klauzule kszta\u0142tuj\u0105 projekt panelu:<\/p>\n  <ul>\n    <li><strong>Dedykowany obw\u00f3d EV i brak przewodu PEN (klauzule 722.314.101 i 722.312.2.1):<\/strong> Do przesy\u0142u energii do\/z pojazdu elektrycznego nale\u017cy zapewni\u0107 dedykowany obw\u00f3d, a w systemach TN ko\u0144cowy obw\u00f3d zasilaj\u0105cy punkt przy\u0142\u0105czeniowy nie mo\u017ce zawiera\u0107 przewodu PEN.<\/li>\n    <li><strong>Ochrona indywidualna a wyj\u0105tek dotycz\u0105cy wielu punkt\u00f3w i jednego wej\u015bcia (klauzula 722.533.101):<\/strong> Ka\u017cdy punkt przy\u0142\u0105czeniowy musi by\u0107 zasilany indywidualnie przez obw\u00f3d ko\u0144cowy zabezpieczony przed przet\u0119\u017ceniem \u2014<em>z wyj\u0105tkiem<\/em> gdzie IEC 61851-1 EVSE z wi\u0119cej ni\u017c jednym punktem pod\u0142\u0105czenia zawiera wymagane wewn\u0119trzne urz\u0105dzenia zabezpieczaj\u0105ce przed przet\u0119\u017ceniem zgodnie <strong>IEC 61851-1:2017, 13.1<\/strong>W przypadku \u0142adowarek z dwoma wyj\u015bciami (takich jak \u0142adowarka BCPCM z jednym wej\u015bciem firmy EVB lub \u0142adowarka BCPCV zam\u00f3wiona z jednym lub dwoma wej\u015bciami) nale\u017cy osobno sprawdzi\u0107 g\u0142\u00f3wny przew\u00f3d zasilaj\u0105cy, wewn\u0119trzne zabezpieczenie punktowe i rozdzielnic\u0119 wst\u0119puj\u0105c\u0105 na schemacie okablowania ka\u017cdego modelu.<\/li>\n    <li><strong>Wsp\u00f3\u0142czynnik r\u00f3\u017cnorodno\u015bci = 1 Bez kontroli obci\u0105\u017cenia (klauzula 722.311):<\/strong> Instalacje wielo\u0142adowarkowe musz\u0105 zak\u0142ada\u0107 jednoczesne pe\u0142ne obci\u0105\u017cenie (wsp\u00f3\u0142czynnik r\u00f3\u017cnorodno\u015bci = <strong>1<\/strong>) chyba \u017ce zweryfikowano Zarz\u0105dzanie obci\u0105\u017ceniem (LMS\/DLB \u2014 opcjonalna funkcja w wielu modelach EVSE) aktywnie ogranicza \u0142\u0105czny pr\u0105d.<\/li>\n    <li><strong>Indywidualny wy\u0142\u0105cznik r\u00f3\u017cnicowopr\u0105dowy 30 mA + p\u0142ynna ochrona DC lub separacja elektryczna (klauzule 722.411.3.3, 722.531.2.101 \/ HD 722.531.3.101 i 722.413):<\/strong> Ka\u017cdy punkt pod\u0142\u0105czenia pr\u0105du przemiennego chroniony automatycznym roz\u0142\u0105czeniem wymaga indywidualnego \u2264<strong>30 mA<\/strong> RCD (minimum typu A) od\u0142\u0105czaj\u0105cy wszystkie przewody pod napi\u0119ciem. Chyba \u017ce klauzula <strong>722.413<\/strong> separacja elektryczna poprzez <strong>IEC 61558-2-4<\/strong> transformator izolacyjny (\u2264500 V, zasilaj\u0105cy <strong>tylko jeden pojazd elektryczny<\/strong>) jest u\u017cywany, ka\u017cdy punkt trybu 3 z gniazdem lub z\u0142\u0105czem IEC 62196 wymaga r\u00f3wnie\u017c \u015brodk\u00f3w przeciwko pr\u0105dowi zwarciowemu DC \u2014 albo <strong>RCD typu B<\/strong> (IEC 62423) <em>Lub<\/em> jaki\u015b <strong>RCD typu A\/F w po\u0142\u0105czeniu z urz\u0105dzeniem wykrywaj\u0105cym pr\u0105d sta\u0142y resztkowy (RDC-DD, g\u0142adki pr\u00f3g pr\u0105du sta\u0142ego 6 mA) zgodny z <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32963\" rel=\"nofollow\">IEC 62955:2018<\/a><\/strong>.<\/li>\n  <\/ul>\n  <p><strong>Wyb\u00f3r zabezpieczenia dla skrzynki \u015bciennej EVB.<\/strong> Ten <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Wall-mounted-AC-EV-Charger-2024.09.06.pdf\">wallbox OCPP pierwszej generacji<\/a> I <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-2nd-Generation-OCPP-Wall-mounted-AC-EV-Charger-2025.11.04.pdf\">skrzynka \u015bcienna drugiej generacji ze sta\u0142ym kablem<\/a> Oba urz\u0105dzenia posiadaj\u0105 wbudowany czujnik up\u0142ywu pr\u0105du sta\u0142ego 6 mA. U\u017cyj schematu okablowania wybranego modelu, aby zidentyfikowa\u0107 urz\u0105dzenie od\u0142\u0105czaj\u0105ce zasilanie w przypadku awarii oraz wymagany wy\u0142\u0105cznik r\u00f3\u017cnicowopr\u0105dowy (RCD). W przypadku wy\u0142\u0105cznika r\u00f3\u017cnicowopr\u0105dowego typu A lub typu F sparowanego z wy\u0142\u0105cznikiem r\u00f3\u017cnicowopr\u0105dowym (RDC-DD) nale\u017cy potwierdzi\u0107 zgodno\u015b\u0107 dokumentacji IEC 62955 z EVB.<\/p>\n\n  <h3 id=\"layer-3-emc-earthing-and-public-billing\">Warstwa 3 i 4 \u2014 klasa EMC A i B, wyj\u0105tek trybu 2 AFIR UE, uziemienie krajowe i obszary niezagro\u017cone wybuchem<\/h3>\n  <ul>\n    <li><strong>UE AFIR (<a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2023\/1804\/2026-01-08\/eng\" rel=\"nofollow\">Rozporz\u0105dzenie (UE) 2023\/1804, ujednolicone 8 stycznia 2026 r.<\/a>) \u2014 Wyj\u0105tek gniazda trybu 2 i terminal p\u0142atniczy puli:<\/strong> Pod <strong>Za\u0142\u0105cznik II, Sekcja 1.1<\/strong>, punkty \u0142adowania pr\u0105dem zmiennym o normalnej mocy dla lekkich pojazd\u00f3w elektrycznych, instalowanych lub odnawianych <strong>8 stycznia 2026 r.<\/strong> musi by\u0107 wyposa\u017cony, w celu zapewnienia interoperacyjno\u015bci, co najmniej w <strong>EN IEC 62196-2:2022 Typ 2<\/strong> gniazda\/z\u0142\u0105cza\u2014<strong>lub, je\u017celi \u22643,7 kW i przede wszystkim do \u0142adowania w trybie 2, gniazdka zgodne z norm\u0105 IEC 60884-1:2022<\/strong>. Osobno, <strong>Artyku\u0142 5(1)<\/strong> ustala dora\u017ane zasady p\u0142atno\u015bci dla p\u0142atnych punkt\u00f3w publicznie dost\u0119pnych, wdra\u017canych od 13 kwietnia 2024 r. (zwolnione s\u0105 punkty bezp\u0142atne, jeden terminal p\u0142atniczy lub urz\u0105dzenie mo\u017ce obs\u0142ugiwa\u0107 kilka punkt\u00f3w) <strong>w tym samym basenie \u0142adowania<\/strong>, a istniej\u0105ce punkty TEN-T \u226550 kW \/ bezpieczne miejsca parkingowe obowi\u0105zuj\u0105 od 1 stycznia 2027 r.); W Wielkiej Brytanii obowi\u0105zuj\u0105 zasady <a href=\"https:\/\/www.gov.uk\/government\/publications\/the-public-charge-point-regulations-2023-guidance\/public-charge-point-regulations-2023-guidance\" rel=\"nofollow\">Przepisy dotycz\u0105ce publicznych punkt\u00f3w \u0142adowania z 2023 r.<\/a>.<\/li>\n    <li><strong>IEC 61851-21-2 EMC Klasa A kontra Klasa B:<\/strong> Jak zauwa\u017cono w <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/EV_charging_station_design\" rel=\"nofollow\">Przewodnik po projektowaniu stacji \u0142adowania pojazd\u00f3w elektrycznych Schneider Electric<\/a>, <strong>Klasa B<\/strong> sprz\u0119t do \u0142adowania poza pojazdem nadaje si\u0119 do obiekt\u00f3w mieszkalnych i miejsc bezpo\u015brednio pod\u0142\u0105czonych do sieci niskiego napi\u0119cia w budynkach mieszkalnych, natomiast <strong>Klasa A<\/strong> sprz\u0119t mo\u017ce by\u0107 u\u017cywany wy\u0142\u0105cznie w miejscach niemieszkalnych.<\/li>\n    <li><strong>Krajowa metrologia uziemienia i rozlicze\u0144:<\/strong> Projektanci projekt\u00f3w musz\u0105 zweryfikowa\u0107 przepisy dotycz\u0105ce uziemienia obowi\u0105zuj\u0105ce w danym kraju \u2013 na przyk\u0142ad instalacje w Wielkiej Brytanii musz\u0105 potwierdzi\u0107 dok\u0142adne \u015brodki ochronne dla dostaw PME (TN-CS) i zewn\u0119trznych lokalizacji \u0142adowania w oparciu o aktualn\u0105 wersj\u0119 <a href=\"https:\/\/electrical.theiet.org\/bs-7671-18th-edition-wiring-regulations\/ensure-you-are-up-to-date-with-bs-7671\" rel=\"nofollow\">BS 7671 Sekcja 722<\/a>, a niekt\u00f3re pojazdy elektryczne ograniczaj\u0105 \u0142adowanie w trybach 1\u20133 w systemach uziemienia IT. W przypadku rozlicze\u0144 za kWh nale\u017cy zweryfikowa\u0107 zakres MID (lub kalibracji krajowej) dla ka\u017cdego modelu i fazy \u2013 na przyk\u0142ad karta katalogowa Mennekes AMTRON ogranicza zintegrowan\u0105 aprobat\u0119 MID do <strong>tylko po\u0142\u0105czenie tr\u00f3jfazowe<\/strong>.<\/li>\n    <li><strong>Granice \u015brodowiskowe i obszary nieska\u017cone:<\/strong> Zgodnie z norm\u0105 IEC 61851-1 urz\u0105dzenia bazowe dzia\u0142aj\u0105 na wysoko\u015bci do 2000 m n.p.m. i w temperaturach do -25\u00b0C na zewn\u0105trz (-5\u00b0C w pomieszczeniach). Standardowe \u0142adowarki do pojazd\u00f3w elektrycznych s\u0105 przeznaczone do: <strong>tylko w miejscach niesklasyfikowanych jako niebezpieczne<\/strong>\u2014zgodnie z instrukcj\u0105 instalacji BCPCV firmy EVB, nigdy nie nale\u017cy instalowa\u0107 urz\u0105dze\u0144 w pobli\u017cu \u0142atwopalnych, wybuchowych lub palnych opar\u00f3w bez oddzielnego certyfikatu dla obszar\u00f3w niebezpiecznych.<\/li>\n  <\/ul>\n\n  <h2 id=\"evb-mode-2-and-mode-3-hardware-comparison\">3. Wyb\u00f3r \u0142adowarki EVB Mode 2 lub Mode 3<\/h2>\n\n  <p>Zacznij od dost\u0119pnej mocy na miejscu. W przypadku \u0142adowarki stacjonarnej zdecyduj, czy kierowcy przynios\u0105 ze sob\u0105 kabel, czy skorzystaj\u0105 z kabla pod\u0142\u0105czonego do stacji. Karty katalogowe poszczeg\u00f3lnych modeli w tabeli pochodz\u0105 z <a href=\"https:\/\/www.evb.com\/pl\/guides-videos\/\">Centrum pobierania EVB<\/a>.<\/p>\n\n  <figure class=\"evb-article-figure\">\n    <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-mode-2-vs-mode-3-hardware-and-rcd-matrix.webp\" target=\"_blank\" rel=\"noopener\" title=\"Otw\u00f3rz \u015bcie\u017cki ochrony IEC 60364-7-722 w pe\u0142nej rozdzielczo\u015bci i przegl\u0105d wsp\u00f3\u0142czynnika kszta\u0142tu EVB\">\n      <img src=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-mode-2-vs-mode-3-hardware-and-rcd-matrix.webp\" alt=\"Schemat neutralny j\u0119zykowo, przedstawiaj\u0105cy trzy opcje ochrony trybu 3 normy IEC 60364-7-722 (30 mA typu A lub F plus IEC 62955 RDC-DD, 30 mA typu B RCD lub transformator izolacyjny zgodny z klauzul\u0105 722.413 dla jednego pojazdu elektrycznego) na tle czterech minimalistycznych sylwetek EVB: BCPP-A1-16, BCPP-A1-32, BCP-A2N\/B2N i BCPCM\/BCPCV.\" width=\"920\" height=\"480\" loading=\"lazy\" decoding=\"async\" \/>\n    <\/a>\n    <figcaption>U g\u00f3ry: Dozwolone \u015bcie\u017cki ochrony pr\u0105du przemiennego zgodnie z norm\u0105 IEC 60364-7-722 dla punkt\u00f3w trybu 3 (30 mA typ A\/F + IEC 62955 6 mA DC RDC-DD, 30 mA typ B RCD zgodnie z norm\u0105 IEC 62423 lub klauzul\u0105 722.413, separacja elektryczna poprzez transformator izolacyjny IEC 61558-2-4 zasilaj\u0105cy tylko jeden pojazd elektryczny). U do\u0142u: Cztery formaty \u0142adowarek EVB. <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2024\/11\/7KW-wall-mountedportable-ac-ev-charger-1112.pdf\">BCPP-A1-32<\/a> ma standardow\u0105 d\u0142ugo\u015b\u0107 ca\u0142kowit\u0105 5 m. Modele przeno\u015bne z ekranem dotykowym w poni\u017cszej tabeli maj\u0105 standardow\u0105 d\u0142ugo\u015b\u0107 ca\u0142kowit\u0105 7 m. Dotknij lub kliknij, aby wy\u015bwietli\u0107 pe\u0142n\u0105 rozdzielczo\u015b\u0107.<\/figcaption>\n  <\/figure>\n\n  <p class=\"evb-table-title\" id=\"tbl-evb-title\">Specyfikacje \u0142adowarek EVB Mode 2 i Mode 3 wed\u0142ug modelu<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-evb-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">Seria EVB i \u0142\u0105cze<\/th>\n          <th scope=\"col\">Tryb \u0142adowania i arkusz danych<\/th>\n          <th scope=\"col\">Moc, napi\u0119cie i pr\u0105d<\/th>\n          <th scope=\"col\">Po\u0142\u0105czenia i funkcje<\/th>\n          <th scope=\"col\">Co nale\u017cy okre\u015bli\u0107 przy sk\u0142adaniu zam\u00f3wienia<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/pl\/product-item\/portable-ac-ev-charger-2\/\">\u0141adowarka przeno\u015bna BCPP-A1-16<\/a><\/th>\n          <td><strong>Tryb 2<\/strong>. Ten <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-Unsmart-Portable-AC-EV-Charger-2025.08.13.pdf\">Karta katalogowa BCPP-A1-16<\/a> wymienia normy IEC 62752 i IEC 61851-21-2.<\/td>\n          <td>A\u017c do <strong>3,7 kW<\/strong> przy napi\u0119ciu 230 V jednofazowym. Regulowany od 8 do 16 A.<\/td>\n          <td>IP66. Standardowa d\u0142ugo\u015b\u0107 ca\u0142kowita 7 m. Zakres pracy od \u221230 do +50 \u00b0C, poni\u017cej 2000 m.<\/td>\n          <td>Wybierz wtyczk\u0119 odpowiedni\u0105 do miejsca instalacji. Wtyczka brytyjska ma pr\u0105d znamionowy 13 A przy napi\u0119ciu 250 V, a wtyczka ameryka\u0144ska 15 A przy napi\u0119ciu 125 V. Sprawd\u017a dopuszczalny pr\u0105d ci\u0105g\u0142y i zabezpieczenie termiczne wtyczki podczas instalacji. Najni\u017csze ustawienie urz\u0105dzenia to 8 A.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/pl\/product-item\/portable-wall-mounted-2-in-1\/\">Inteligentna \u0142adowarka przeno\u015bna BCPP-A2N-32 \/ BCPP-AT2N-32<\/a><\/th>\n          <td><strong>Tryb 2<\/strong> z wtyczk\u0105 przemys\u0142ow\u0105 CEE. Zobacz <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-Smart-Portable-Wall-mounted-AC-EV-Charger-2024.09.06.pdf\">karta katalogowa inteligentnego urz\u0105dzenia przeno\u015bnego\/montowanego na \u015bcianie<\/a>.<\/td>\n          <td><strong>7,4 kW<\/strong> przy 230 V jednofazowym (A2N) lub <strong>22 kW<\/strong> przy 400 V tr\u00f3jfazowym (AT2N). Oba regulowane od 6 do 32 A.<\/td>\n          <td>Ekran dotykowy o przek\u0105tnej 4,3 cala. W karcie katalogowej podano norm\u0119 IP65 i standardow\u0105 d\u0142ugo\u015b\u0107 ca\u0142kowit\u0105 7 m. Dynamiczne r\u00f3wnowa\u017cenie obci\u0105\u017cenia jest opcjonalne.<\/td>\n          <td>Dopasuj wtyczk\u0119 CEE do zasilania na miejscu. Je\u015bli projekt wymaga stopnia ochrony IP66, uwzgl\u0119dnij to w zapytaniu ofertowym, aby EVB mog\u0142o potwierdzi\u0107 obudow\u0119 dla zam\u00f3wionego urz\u0105dzenia.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Wallbox OCPP pierwszej generacji \u00b7 <a href=\"https:\/\/www.evb.com\/pl\/product-item\/ac-ev-charger-with-cable-2\/\">kabel sta\u0142y<\/a> Lub <a href=\"https:\/\/www.evb.com\/pl\/product-item\/ac-ev-charger-with-socket-2\/\">Gniazdo typu 2<\/a><\/th>\n          <td><strong>Tryb 3<\/strong>. Ten <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Wall-mounted-AC-EV-Charger-2024.09.06.pdf\">karta danych wallboxa pierwszej generacji<\/a> obejmuje oba po\u0142\u0105czenia.<\/td>\n          <td>Modele 32 A zapewniaj\u0105 do <strong>7,4 kW<\/strong> jednofazowy lub <strong>22 kW<\/strong> tr\u00f3jfazowe. Wersje 16 A maj\u0105 moc odpowiednio 3,7 lub 11 kW.<\/td>\n          <td>Kabel sta\u0142y 5 m (obudowa C), IP65, w modelach BCP-A2N-P \/ BCP-AT2N-P. Gniazdo typu 2 do kabla od\u0142\u0105czanego (obudowa B), IP55, w modelach BCP-B2N-P \/ BCP-BT2N-P.<\/td>\n          <td>Najpierw wybierz po\u0142\u0105czenie i liczb\u0119 faz. Wszystkie cztery modele 32 A obs\u0142uguj\u0105 protok\u00f3\u0142 OCPP 1.6-J. Dynamiczne r\u00f3wnowa\u017cenie obci\u0105\u017cenia i zewn\u0119trzny licznik MID s\u0105 opcjami.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/pl\/product-item\/2nd-generation-ocpp-wall-mounted-ac-ev-charger\/\">Wallbox OCPP drugiej generacji<\/a> \u00b7 BCP-A2M-P \/ BCP-AT2M-P<\/th>\n          <td><strong>Tryb 3<\/strong> z kablem sta\u0142ym. Zobacz <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-2nd-Generation-OCPP-Wall-mounted-AC-EV-Charger-2025.11.04.pdf\">karta katalogowa wallboxa drugiej generacji<\/a>.<\/td>\n          <td>BCP-A2M-P zapewnia do <strong>7,4 kW<\/strong> przy 230 V jednofazowym. BCP-AT2M-P dostarcza do <strong>22 kW<\/strong> przy napi\u0119ciu 400 V tr\u00f3jfazowym. Oba modele to 32 A.<\/td>\n          <td>Kabel sta\u0142y o d\u0142ugo\u015bci 5 m (obudowa C), IP65, IK10 i OCPP 1.6-J. Dynamiczne r\u00f3wnowa\u017cenie obci\u0105\u017cenia i zewn\u0119trzny licznik MID s\u0105 opcjonalne.<\/td>\n          <td>W przypadku lokalizacji z ograniczeniem do 16 A na faz\u0119 nale\u017cy okre\u015bli\u0107 BCP-A2M-P-16 (3,7 kW) lub BCP-AT2M-P-16 (11 kW).<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/pl\/product-item\/type-2-mode-3-ev-charger\/\">\u0141adowarka \u015bcienna BCPCM z podw\u00f3jnym kablem<\/a><\/th>\n          <td><strong>Tryb 3<\/strong> z dwoma sta\u0142ymi kablami. Zobacz <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Wall-mounted-Dual-Cable-AC-EV-Charger-Metal-Enclosure-2025.04.07.pdf\">Karta katalogowa podw\u00f3jnego kabla BCPCM<\/a>.<\/td>\n          <td>BCPCM-C2N-P: <strong>2 \u00d7 7,4 kW<\/strong> przy 230 V w uk\u0142adzie jednofazowym. Przy 400 V w uk\u0142adzie tr\u00f3jfazowym BCPCM-CT2N-P-16 zapewnia <strong>2 \u00d7 11 kW<\/strong> i BCPCM-CT2N-P <strong>2 \u00d7 22 kW<\/strong>.<\/td>\n          <td>Dwa kable 5 m, IP65, dwa mierniki MID i OCPP 1.6-J.<\/td>\n          <td>Oba punkty \u0142adowania korzystaj\u0105 z jednego wej\u015bcia zasilania. U\u017cyj schematu okablowania wybranego modelu, aby okre\u015bli\u0107 rozmiar zasilacza i dopasowa\u0107 zabezpieczenia dla ka\u017cdego punktu.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/pl\/product-item\/floor-mounted-ac-ev-charger-with-socket\/\">Podw\u00f3jna \u0142adowarka BCPCV montowana na pod\u0142odze<\/a> \u00b7 DT2N \/ CT2N<\/th>\n          <td><strong>Tryb 3<\/strong>. Zobacz <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Floor-mounted-AC-EV-Charger-2025.07.11.pdf\">Karta katalogowa coko\u0142u BCPCV serii N<\/a>.<\/td>\n          <td>W przypadku sieci tr\u00f3jfazowej 400 V, BCPCV-DT2N-P i BCPCV-CT2N-P s\u0105 oceniane <strong>2 \u00d7 22 kW<\/strong>. Ich warianty -16 s\u0105 oceniane <strong>2 \u00d7 11 kW<\/strong>.<\/td>\n          <td>DT2N ma dwa gniazda. CT2N ma dwa 5-metrowe kable sta\u0142e. Oba oferuj\u0105 IP54, wbudowany licznik i OCPP 1.6-J.<\/td>\n          <td>Okre\u015bl pojedyncze lub podw\u00f3jne wej\u015bcia zasilania oraz wymagany licznik rozliczeniowy dla danej lokalizacji. Rysunek 4 <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2024\/02\/Floor-Mounted-AC-EV-Charger-0228.pdf\">Instrukcja instalacji BCPCV<\/a> Ilustruje uk\u0142ad z dwoma wej\u015bciami. U\u017cyj do\u0142\u0105czonego schematu okablowania dla zam\u00f3wionej konfiguracji.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">W przypadku centr\u00f3w handlowych, w kt\u00f3rych odnawialna energia pr\u0105du przemiennego w czasie postoju (dost\u0119pna moc pr\u0105du przemiennego kW \u00d7 godziny postoju, uwzgl\u0119dniaj\u0105c straty i obni\u017cenie warto\u015bci znamionowej) jest ni\u017csza od wymaganej dziennej mocy kWh, nale\u017cy zapozna\u0107 si\u0119 z trybem 4 EVB <a href=\"https:\/\/www.evb.com\/pl\/product-item\/floor-mounted-dc-2-guns-ev-dc-fast-charger\/\">Szybkie \u0142adowarki pr\u0105du sta\u0142ego BDC 60\u2013320 kW z dwoma dzia\u0142ami<\/a>. Przesuwaj palcem poziomo na w\u0105skich ekranach.<\/p>\n\n  <h2 id=\"iec-61851-charging-modes-comparison\">4. Pe\u0142ne odniesienie do normy IEC 61851-1: Gdzie pasuj\u0105 tryby 1 i 4 (tryb Plus, obudowa i z\u0142\u0105cze)<\/h2>\n\n  <p>Pod <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/33644\" rel=\"nofollow\">IEC 61851-1:2017<\/a> (Wydanie 3.0, przewodz\u0105cy EVSE o mocy znamionowej \u2264<strong>1000 V pr\u0105du przemiennego lub 1500 V pr\u0105du sta\u0142ego<\/strong>; zobacz tak\u017ce <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/Electric_Vehicle_and_EV_charging_fundamentals\" rel=\"nofollow\">Podr\u0119cznik podstawowy Schneider Electric EV<\/a>), Tryby 1\u20133 dostarczaj\u0105 pr\u0105d przemienny do \u0142adowarki pok\u0142adowej pojazdu, podczas gdy <strong>Tryb 4 dostarcza pr\u0105d sta\u0142y bezpo\u015brednio do pojazdu ze stacji zewn\u0119trznej<\/strong> (<a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32973\" rel=\"nofollow\">IEC 61851-23:2023<\/a> obejmuje \u0142adowarki pr\u0105du sta\u0142ego zar\u00f3wno z wej\u015bciem pr\u0105du przemiennego, jak i sta\u0142ego (najcz\u0119stszym przyk\u0142adem jest szafa prostownika zasilana pr\u0105dem przemiennym):<\/p>\n\n  <p class=\"evb-table-title\" id=\"tbl-modes-title\">IEC 61851-1 Tryby \u0142adowania 1\u20134: warto\u015bci znamionowe, \u015bcie\u017cka sterowania i granice praktyczne<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-modes-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">Tryb \u0142adowania<\/th>\n          <th scope=\"col\">Interfejs zasilania i sprz\u0119t<\/th>\n          <th scope=\"col\">Oceny standardowe<\/th>\n          <th scope=\"col\">Pilot steruj\u0105cy (CP) i ochrona<\/th>\n          <th scope=\"col\">Zakres praktyczny i kluczowe zastrze\u017cenie<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\">Tryb 1<\/th>\n          <td>Gniazdo pr\u0105du zmiennego, standardowe, z prostym przewodem i wtyczk\u0105<\/td>\n          <td>\u2264<strong>16 A<\/strong>; \u2264<strong>250 V pr\u0105du przemiennego<\/strong> (1P) lub \u2264<strong>480 V pr\u0105du przemiennego<\/strong> (3P)<\/td>\n          <td><strong>Brak sygnalizacji CP\/PP<\/strong>; opiera si\u0119 wy\u0142\u0105cznie na istniej\u0105cej ochronie obwod\u00f3w budynku<\/td>\n          <td>Ograniczone lub zabronione dla pojazd\u00f3w elektrycznych na drogach w wielu krajowych przepisach dotycz\u0105cych instalacji elektrycznych ze wzgl\u0119du na przeci\u0105\u017cenie obwodu wsp\u00f3lnego i ryzyko po\u017caru\/pora\u017cenia pr\u0105dem.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Tryb 2<\/th>\n          <td>Gniazdo domowe, domowe z certyfikatem EV lub przemys\u0142owe CEE za po\u015brednictwem przeno\u015bnego <strong>IC-CPD<\/strong> (<a href=\"https:\/\/webstore.iec.ch\/en\/publication\/66220\" rel=\"nofollow\">IEC 62752:2024<\/a>)<\/td>\n          <td>\u2264<strong>32 A<\/strong>; \u2264<strong>250 V pr\u0105du przemiennego<\/strong> (1P) lub \u2264<strong>480 V pr\u0105du przemiennego<\/strong> (3P)<\/td>\n          <td><strong>W kablu IC-CPD<\/strong> zapewnia komunikacj\u0119 CP i ochron\u0119 przed skutkami up\u0142ywu pr\u0105du; Wydanie 2.0 z 2024 r. (podpunkty 8.3.1 i 9.36) wymaga wykrywania temperatury na przewodz\u0105cych pr\u0105d cz\u0119\u015bciach wtyczek domowych<\/td>\n          <td>Najlepiej sprawdza si\u0119 w podr\u00f3\u017cy\/jako zapasowe gniazdka z homologacj\u0105 EV (np. BS 1363-2\/EV, Green&#039;Up) lub zweryfikowane gniazdka CEE; za\u0142\u0105cznik II \u00a71.1 do unijnego rozporz\u0105dzenia AFIR dopuszcza stosowanie gniazdek pr\u0105du przemiennego o mocy \u22643,7 kW w trybie 2 o normalnej mocy i ma\u0142ym obci\u0105\u017ceniu zgodnie z norm\u0105 IEC 60884-1:2022.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Tryb 3<\/th>\n          <td>Pod\u0142\u0105czone na sta\u0142e urz\u0105dzenie AC EVSE (wallbox lub cok\u00f3\u0142) na <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">IEC 60364-7-722<\/a> okr\u0105\u017cenie<\/td>\n          <td>Powszechnie <strong>3,7\u201322 kW<\/strong> (16 A \/ 32 A, 1P lub 3P); <strong>~43,5 kW<\/strong> w okre\u015blonych konfiguracjach 400 V 3-fazowych 63 A<\/td>\n          <td><strong>Sterowanie w \u0142adowarce i prze\u0142\u0105czanie stycznik\u00f3w:<\/strong> Sygnalizacja CP\/PP, kontrola stycznika i PE. <strong>Zabezpieczenie obwod\u00f3w instalacyjnych (IEC 60364-7-722):<\/strong> 30 mA typu A\/F RCD + IEC 62955 6 mA DC RDC-DD, 30 mA typu B RCD lub klauzula 722.413 separacja elektryczna (sprawd\u017a lokalizacj\u0119 panelu wewn\u0119trznego i g\u00f3rnego zgodnie ze schematem okablowania SKU)<\/td>\n          <td>Opcje bazowe dla codziennych instalacji klimatyzacyjnych w domach, miejscach pracy i obiektach publicznych; zarz\u0105dzanie obci\u0105\u017ceniem (DLB), OCPP i liczniki rozliczeniowe MID zale\u017c\u0105 od modelu.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Tryb 4<\/th>\n          <td>Stacja \u0142adowania pr\u0105dem sta\u0142ym poza pok\u0142adem (<a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32973\" rel=\"nofollow\">IEC 61851-23:2023<\/a>; Zasilanie wej\u015bciowe AC lub DC)<\/td>\n          <td>Zasilanie \u22641000 V AC \/ 1500 V DC; wyj\u015bcie \u2264<strong>1500 V pr\u0105du sta\u0142ego<\/strong> (zwykle 50\u2013480 kW+)<\/td>\n          <td>Zaawansowana cyfrowa komunikacja BMS, monitorowanie izolacji, separacja elektryczna, pod\u0142\u0105czony kabel Case C<\/td>\n          <td>Dostarcza pr\u0105d sta\u0142y bezpo\u015brednio do akumulatora, omijaj\u0105c limity mocy AC OBC pojazdu (zwykle 7,4\u201322 kW; do 43 kW pr\u0105du przemiennego w wybranych starszych pojazdach elektrycznych, takich jak wczesne modele). <a href=\"https:\/\/www.press.renault.co.uk\/releases\/502\" rel=\"nofollow\">Renault ZOE<\/a>).<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">Opracowano na podstawie norm IEC 61851-1:2017, IEC 62752:2024, IEC 60364-7-722:2018, IEC 62955:2018, IEC 61851-23:2023 oraz podr\u0119cznika Schneider Electric Electrical Installation Guide. Przesuwaj palcem poziomo na w\u0105skich ekranach.<\/p>\n\n  <h3 id=\"mode-vs-case-vs-type-vs-level\">Nie nale\u017cy myli\u0107 tryb\u00f3w \u0142adowania, obud\u00f3w z\u0142\u0105czy, z\u0142\u0105czy i poziom\u00f3w obowi\u0105zuj\u0105cych w Ameryce P\u00f3\u0142nocnej<\/h3>\n  <ul>\n    <li><strong>Tryb \u0142adowania (tryby 1\u20134 wg normy IEC 61851-1):<\/strong> Definiuje architektur\u0119 zasilania i miejsce, w kt\u00f3rym znajduj\u0105 si\u0119 elementy sterowania\/ochrony.<\/li>\n    <li><strong>Obudowa po\u0142\u0105czeniowa (IEC 61851-1 przypadki A, B, C):<\/strong> Definiuje mocowanie kabla \u2014<strong>Przypadek A<\/strong> (przymocowany do pojazdu), <strong>Przypadek B<\/strong> (od\u0142\u0105czane z obu stron, np. kable trybu 2 lub s\u0142upki gniazd trybu 3) i <strong>Przypadek C<\/strong> (na sta\u0142e pod\u0142\u0105czony do EVSE).<\/li>\n    <li><strong>Rodzina z\u0142\u0105czy (IEC 62196 \/ SAE J1772 \/ SAE J3400):<\/strong> Definiuje fizyczn\u0105 geometri\u0119 wtyczki \u2014 AC typu 1 lub typu 2; DC CCS1, CCS2 lub CHAdeMO; i p\u00f3\u0142nocnoameryka\u0144ski <strong>NACS (<a href=\"https:\/\/driveelectric.gov\/charging-connector\" rel=\"nofollow\">SAE J3400<\/a>)<\/strong>, kt\u00f3ry wspiera <strong>zar\u00f3wno jednofazowego pr\u0105du przemiennego, jak i sta\u0142ego<\/strong> poprzez jedno kompaktowe z\u0142\u0105cze.<\/li>\n    <li><strong>Klasyfikacje \u0142adowania w Ameryce P\u00f3\u0142nocnej (<a href=\"https:\/\/afdc.energy.gov\/fuels\/electricity-stations\" rel=\"nofollow\">Departament Energii USA AFDC<\/a>):<\/strong> Grupy pobieraj\u0105 op\u0142aty w wysoko\u015bci <strong>Poziom AC 1<\/strong> (120 V) <strong>AC Poziom 2<\/strong> (208\/240 V) i <strong>Szybkie \u0142adowanie pr\u0105dem sta\u0142ym<\/strong> (czasami potocznie nazywany \u201ePoziomem 3\u201d) \u2014 nie jest to zmiana nazwy tryb\u00f3w IEC w stosunku 1:1.<\/li>\n  <\/ul>\n\n  <h2 id=\"north-america-ul-2594-parallel\">5. Uwaga regionalna: Mapowanie norm UL 2594 i UL 2231 dla Ameryki P\u00f3\u0142nocnej<\/h2>\n\n  <p>W przypadku flot mi\u0119dzynarodowych rozmieszczonych w sieciach IEC i Ameryki P\u00f3\u0142nocnej nale\u017cy osobno okre\u015bli\u0107 zestawienia regionalne:<\/p>\n  <ul>\n    <li><strong><a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2594\" rel=\"nofollow\">ANSI\/UL 2594<\/a> (Wydanie 3, aktywne, 15 grudnia 2022 r.)<\/strong> reguluje przewodzenie <strong>AC<\/strong> Sprz\u0119t zasilaj\u0105cy pojazdy elektryczne (pr\u0105d przemienny \u22641000 V, 50\/60 Hz); przyk\u0142ady sprz\u0119tu obj\u0119tego klauzul\u0105 1.2 obejmuj\u0105: <strong>Zestawy przewod\u00f3w EV<\/strong>, <strong>stacje \u0142adowania pojazd\u00f3w elektrycznych mocowane na sta\u0142e<\/strong>, <strong>stacje \u0142adowania pojazd\u00f3w elektrycznych na miejscu<\/strong>, I <strong>gniazdka elektryczne montowane na sta\u0142e<\/strong> (W wydaniu 3 usuni\u0119to starszy wym\u00f3g, zgodnie z kt\u00f3rym urz\u0105dzenia o napi\u0119ciu powy\u017cej 125 V musz\u0105 by\u0107 zamocowane na sta\u0142e).<\/li>\n    <li><strong><a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2231-1\" rel=\"nofollow\">ANSI\/UL 2231-1<\/a> (Wydanie 3, 6 listopada 2026 r.) i <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2231-2\" rel=\"nofollow\">UL 2231-2<\/a> (zaktualizowano 15 grudnia 2020 r.)<\/strong> obejmuj\u0105 systemy ochrony personelu (takie jak CCID) dla obwod\u00f3w zasilania pojazd\u00f3w elektrycznych w Ameryce P\u00f3\u0142nocnej.<\/li>\n    <li><strong>Praktyczne wskaz\u00f3wki:<\/strong> Trzyma\u0107 <strong>AC poziom 2 USA<\/strong> r\u00f3\u017cni si\u0119 od trybu IEC 2 i trybu 3 \u2014 poniewa\u017c tryb IEC 2 jest ograniczony do <strong>32 A<\/strong>, p\u00f3\u0142nocnoameryka\u0144skie urz\u0105dzenie 240 V \/ 40 A z wtyczk\u0105 i kablem lub stacja przewodowa 48 A\u201380 A zgodnie z norm\u0105 UL 2594 po prostu opisuje metody pod\u0142\u0105czenia i monta\u017cu (nale\u017cy sprawdzi\u0107 kategori\u0119 instalacji UL 2594 konkretnego modelu podczas zakupu), a nie tryby IEC. Zawsze nale\u017cy wyra\u017anie okre\u015bli\u0107 obowi\u0105zuj\u0105cy regionalny zestaw norm (CE\/CB\/UKCA + IEC 61851-1 \/ IEC 62752 vs. UL\/CSA + UL 2594 \/ UL 2231 + NEC\/CEC) w zapytaniach ofertowych dotycz\u0105cych r\u00f3\u017cnych rynk\u00f3w.<\/li>\n  <\/ul>\n\n  <h2 id=\"rfq-and-commissioning-checklist\">6. Lista kontrolna przed zam\u00f3wieniem i uruchomieniem dla projekt\u00f3w w trybie 2 i 3<\/h2>\n\n  <div class=\"evb-checklist\">\n    <h3>5 kontroli technicznych przed wystawieniem zam\u00f3wienia zakupu<\/h3>\n    <ol>\n      <li><strong>Rozmiar w por\u00f3wnaniu do wszystkich czterech sufit\u00f3w (sie\u0107, EVSE, kabel, pojazd OBC) + dzienne kWh:<\/strong> Dopasuj dzienne zapotrzebowanie na energi\u0119 i czas przebywania do trybu 2 (zasilanie rezerwowe \/ gniazdo przystosowane do pojazd\u00f3w elektrycznych \/ CEE), trybu 3 (codzienne zasilanie pr\u0105dem zmiennym) lub trybu 4 (poza pok\u0142adem pr\u0105d sta\u0142y) i okre\u015bl, czy urz\u0105dzenie ma by\u0107 pod\u0142\u0105czone (przypadek C), czy pod\u0142\u0105czone do gniazda (przypadek B).<\/li>\n      <li><strong>Koordynacja \u0142adowarki i tablicy rozdzielczej.<\/strong> Popro\u015b o schemat okablowania modelu i zalecane zabezpieczenia przed przepi\u0119ciem. Je\u015bli projekt wykorzystuje wy\u0142\u0105cznik r\u00f3\u017cnicowopr\u0105dowy typu A lub F z wy\u0142\u0105cznikiem r\u00f3\u017cnicowopr\u0105dowym typu RDC-DD, sprawd\u017a dokumentacj\u0119 normy IEC 62955 dotycz\u0105c\u0105 uk\u0142adu wykrywania i od\u0142\u0105czania. W przypadku podw\u00f3jnej \u0142adowarki z jednym zasilaniem, zlokalizuj zabezpieczenie nadpr\u0105dowe dla ka\u017cdego gniazda (klauzula 722.533.101). Sprawd\u017a lokalne wymagania dotycz\u0105ce uziemienia, takie jak norma BS 7671, sekcja 722 w Wielkiej Brytanii.<\/li>\n      <li><strong>Potwierd\u017a opcjonalne zarz\u0105dzanie obci\u0105\u017ceniem, OCPP i pomiary wed\u0142ug SKU:<\/strong> Liczniki rozliczeniowe DLB\/LMS, OCPP i MID\/krajowe nale\u017cy traktowa\u0107 jako opcje zale\u017cne od modelu \u2014 nale\u017cy je wyra\u017anie zablokowa\u0107 w ofercie przed ustaleniem rozmiaru zasilaczy zgodnie z klauzul\u0105 722.311 normy IEC 60364-7-722 (wsp\u00f3\u0142czynnik r\u00f3\u017cnorodno\u015bci = 1 bez aktywnej kontroli obci\u0105\u017cenia).<\/li>\n      <li><strong>Oddzielne dowody test\u00f3w produktu, klasa EMC i dost\u0119p do rynku:<\/strong> Z\u0142\u00f3\u017c wniosek o dowody test\u00f3w IEC 61851-1 \/ IEC 62752 dla konkretnego SKU, potwierd\u017a norm\u0119 IEC 61851-21-2 EMC klasy B dla sieci domowych (w por\u00f3wnaniu z klas\u0105 A dla sieci komercyjnych), zweryfikuj zakres rozlicze\u0144 MID dla sieci 1-fazowych w por\u00f3wnaniu z 3-fazowymi oraz z\u0142\u00f3\u017c wniosek o dokumentacj\u0119 EU DoC, UKCA lub UL\/CSA dla rynku docelowego.<\/li>\n      <li><strong>Kontrola miejsca instalacji i granic stref niebezpiecznych podczas przekazania:<\/strong> Przed pod\u0142\u0105czeniem zasilania sprawd\u017a oznakowanie dedykowanego obwodu, klas\u0119 ochrony IP\/IK obudowy dla konkretnego modelu i po\u0142\u0105czenia, zestawy przed\u0142u\u017caczy bezprzewodowych, zweryfikowane odst\u0119py w miejscach niebezpiecznych oraz funkcjonalne zapisy testu wy\u0142\u0105cznika r\u00f3\u017cnicowopr\u0105dowego \/ ci\u0105g\u0142o\u015bci uziemienia.<\/li>\n    <\/ol>\n  <\/div>\n\n  <div class=\"evb-callout\">\n    <h3>Jakie \u0142adowarki pr\u0105du przemiennego wybra\u0107: tryb 2, przeno\u015bny, czy tryb 3?<\/h3>\n    <p>Udost\u0119pnij zespo\u0142owi in\u017cynier\u00f3w EVB informacje o swoim rynku docelowym (UE\/AFIR, Wielka Brytania, APAC lub Ameryka P\u00f3\u0142nocna), zasilaniu pr\u0105dem zmiennym (230 V 1-fazowe lub 400 V 3-fazowe), liczbie stanowisk, dziennym zu\u017cyciu kWh na pojazd i opcjonalnych wymaganiach OCPP\/DLB\/MID, aby potwierdzi\u0107 dok\u0142adne schematy okablowania SKU i koordynacj\u0119 zabezpiecze\u0144 wst\u0119puj\u0105cych.<\/p>\n    <a class=\"evb-cta-btn\" href=\"https:\/\/www.evb.com\/pl\/ev-charger-customization\/\">Zapytaj o specyfikacj\u0119 i dostosowanie \u0142adowarki EVB<\/a>\n  <\/div>\n\n  <h2 id=\"frequently-asked-questions\">7. Cz\u0119sto zadawane pytania<\/h2>\n\n  <h3 id=\"faq-mode-2-daily-charging\">Czy mog\u0119 codziennie u\u017cywa\u0107 w domu przeno\u015bnej \u0142adowarki Mode 2 (\u201e3-pinowej\u201d lub \u201egranny\u201d)?<\/h3>\n  <p>\u0141adowarka sieciowa Mode 2 IC-CPD zgodna z norm\u0105 IEC 62752 jest przeznaczona do bezpiecznego, przeno\u015bnego i okazjonalnego \u0142adowania, a nie jako d\u0142ugoterminowy zamiennik stacjonarnej \u0142adowarki \u015bciennej Mode 3 pod\u0142\u0105czonej do zwyk\u0142ych gniazdek domowych. Poniewa\u017c sama obci\u0105\u017calno\u015b\u0107 pr\u0105dowa gniazdka domowego nie gwarantuje jego przydatno\u015bci do d\u0142ugotrwa\u0142ego, codziennego \u0142adowania pojazd\u00f3w elektrycznych, nale\u017cy przestrzega\u0107 lokalnych wytycznych (na przyk\u0142ad, du\u0144skie wytyczne wymagaj\u0105, aby gniazdo by\u0142o przeznaczone do d\u0142ugotrwa\u0142ego, wysokiego obci\u0105\u017cenia, je\u015bli \u0142adowanie ma trwa\u0107 d\u0142u\u017cej ni\u017c dwie godziny), u\u017cywa\u0107 krajowego gniazdka domowego z homologacj\u0105 dla pojazd\u00f3w elektrycznych w wydzielonym obwodzie z kompatybilnym kablem (takim jak brytyjska norma BS 1363-2\/EV lub francuska norma Green&#039;Up, je\u015bli jest dozwolona) lub \u2013 najlepiej do regularnego, codziennego \u0142adowania \u2013 zainstalowa\u0107 dedykowan\u0105 \u0142adowark\u0119 \u015bcienn\u0105 Mode 3 zweryfikowan\u0105 przez wykwalifikowanego elektryka.<\/p>\n\n  <h3 id=\"faq-mode-2-cee-22kw\">Czy \u0142adowarka Mode 2 mo\u017ce dostarczy\u0107 11 kW lub 22 kW za po\u015brednictwem gniazda przemys\u0142owego CEE?<\/h3>\n  <p>Tak \u2014 norma IEC 61851-1 zezwala na tryb 2 do <strong>32 A przy 250 V AC (1-fazowe) lub 480 V AC (3-fazowe)<\/strong>. Wydajno\u015b\u0107 zale\u017cy od konkretnej wtyczki CEE, liczby faz i mocy znamionowej obwodu: <strong>400 V tr\u00f3jfazowy<\/strong>, <strong>16 A dostarcza ~11 kW<\/strong> I <strong>32 A dostarcza ~22 kW<\/strong>; NA <strong>230 V jednofazowe<\/strong>, <strong>16 A dostarcza ~3,7 kW<\/strong> I <strong>32 A dostarcza ~7,4 kW<\/strong> (jak w przypadku serii przeno\u015bnych urz\u0105dze\u0144 2 w 1 EVB o mocy 7,4 kW \/ 22 kW), zawsze ograniczonej najni\u017cszym parametrem spo\u015br\u00f3d zasilacza sieciowego, wtyczki\/przewodu, \u0142adowarki przeno\u015bnej i \u0142adowarki samochodowej. Gniazdo przemys\u0142owe CEE musi by\u0107 pod\u0142\u0105czone do dedykowanego obwodu zgodnego z norm\u0105 IEC 60364-7-722 ze zweryfikowanym zabezpieczeniem r\u00f3\u017cnicowopr\u0105dowym\/nadpr\u0105dowym przed urz\u0105dzeniem, a przed u\u017cyciem trybu CEE 2 do \u0142adowania w miejscu pracy lub w miejscach publicznych nale\u017cy sprawdzi\u0107 przepisy krajowe.<\/p>\n\n  <h3 id=\"faq-mode-3-type-a-vs-type-b-rcd\">Czy \u0142adowarka trybu 3 z wbudowanym czujnikiem pr\u0105du sta\u0142ego 6 mA nadal wymaga wy\u0142\u0105cznika r\u00f3\u017cnicowopr\u0105dowego typu B?<\/h3>\n  <p>Pod <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">IEC 60364-7-722:2018<\/a>, ka\u017cdy punkt po\u0142\u0105czeniowy trybu 3 chroniony automatycznym roz\u0142\u0105czaniem wymaga albo <strong>30 mA wy\u0142\u0105cznik r\u00f3\u017cnicowopr\u0105dowy typu B<\/strong> <em>Lub<\/em> A <strong>30 mA wy\u0142\u0105cznik r\u00f3\u017cnicowopr\u0105dowy typu A (lub typu F) sparowany z <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32963\" rel=\"nofollow\">IEC 62955<\/a> 6 mA pr\u0105du sta\u0142ego RDC-DD<\/strong> (chyba \u017ce klauzula 722.413 przewiduje separacj\u0119 elektryczn\u0105 za pomoc\u0105 transformatora izolacyjnego IEC 61558-2-4, kt\u00f3ry zasila tylko jeden pojazd elektryczny). U\u017cyj schematu okablowania modelu i instrukcji instalacji, aby zidentyfikowa\u0107 urz\u0105dzenia zapewniaj\u0105ce wykrywanie i od\u0142\u0105czanie, a nast\u0119pnie wybierz wy\u0142\u0105cznik r\u00f3\u017cnicowopr\u0105dowy (RCD) w g\u00f3rnym biegu przewodu dla danej lokalizacji zgodnie z obowi\u0105zuj\u0105cymi przepisami krajowymi.<\/p>\n\n  <h3 id=\"faq-mode-vs-type-and-level\">Jaka jest r\u00f3\u017cnica pomi\u0119dzy trybem 2\/3, typem 1\/2, a szybkim \u0142adowaniem AC Level 1 \/ Level 2 \/ DC?<\/h3>\n  <p><strong>Tryby 1\u20134<\/strong> Norma (IEC 61851-1) opisuje architektur\u0119 \u0142adowania oraz lokalizacj\u0119 element\u00f3w steruj\u0105cych\/zabezpieczaj\u0105cych. <strong>Typ 1 i Typ 2<\/strong> Normy (IEC 62196-2) opisuj\u0105 fizyczn\u0105 geometri\u0119 z\u0142\u0105cza pr\u0105du przemiennego \u2014 zar\u00f3wno kable trybu 2, jak i stacje trybu 3 powszechnie wykorzystuj\u0105 z\u0142\u0105cza typu 2 w Europie i na \u015bwiatowych rynkach IEC. <strong>Poziom AC 1, poziom AC 2 i szybkie \u0142adowanie DC<\/strong> (czasami potocznie nazywane \u201ePoziomem 3\u201d) to klasyfikacje p\u00f3\u0142nocnoameryka\u0144skie stosowane obok <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2594\" rel=\"nofollow\">ANSI\/UL 2594<\/a> (dla AC EVSE), a nie tryb\u00f3w IEC.<\/p>\n\n  <h3 id=\"faq-extension-cord-ev-charging\">Dlaczego przed\u0142u\u017cacze s\u0105 zabronione w przypadku kabli \u0142aduj\u0105cych w trybie 2 i 3?<\/h3>\n  <p>Standardowe przed\u0142u\u017cacze kablowe dodaj\u0105 dodatkow\u0105, niemonitorowan\u0105 rezystancj\u0119 styku, nie posiadaj\u0105 czujnika temperatury na po\u015brednim z\u0142\u0105czu wtyczka-gniazdo, mog\u0105 si\u0119 mocno przegrzewa\u0107 podczas zwijania pod ci\u0105g\u0142ym obci\u0105\u017ceniem pojazdu elektrycznego oraz mog\u0105 narusza\u0107 ci\u0105g\u0142o\u015b\u0107 uziemienia ochronnego lub szczelno\u015b\u0107 IP. Zar\u00f3wno instrukcje instalacji IEC, jak i oficjalne instrukcje EVB wyra\u017anie zabraniaj\u0105 stosowania przed\u0142u\u017caczy; zamiast tego nale\u017cy zam\u00f3wi\u0107 kabel zatwierdzony przez producenta, kt\u00f3ry si\u0119ga do gniazda w poje\u017adzie, lub zmieni\u0107 lokalizacj\u0119 sta\u0142ego urz\u0105dzenia Mode 3.<\/p>\n\n  <h2 id=\"references\">8. Podstawowe normy i odniesienia techniczne<\/h2>\n  <ul>\n    <li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/33644\" rel=\"nofollow\">IEC 61851-1:2017 (wydanie 3.0)<\/a> \u2014 System \u0142adowania przewodowego pojazd\u00f3w elektrycznych, Cz\u0119\u015b\u0107 1: Wymagania og\u00f3lne (opublikowano 2017-02-07; dost\u0119p 21 listopada 2026 r.).<\/li>\n    <li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/66220\" rel=\"nofollow\">IEC 62752:2024 (wydanie 2.0)<\/a> \u2014 Urz\u0105dzenie steruj\u0105ce i zabezpieczaj\u0105ce w kablu (IC-CPD) do \u0142adowania pojazd\u00f3w elektrycznych w trybie 2 (opublikowano 27.03.2024; podpunkty 8.3.1 i 9.36; dost\u0119p 21 listopada 2026 r.).<\/li>\n    <li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">IEC 60364-7-722:2018 (wydanie 2.0)<\/a> (klauzule 722.311, 722.312.2.1, 722.314.101, 722.411.3.3, 722.413, 722.531.2.101, 722.533.101) i <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32963\" rel=\"nofollow\">IEC 62955:2018 (wydanie 1.0)<\/a> (RDC-DD dla trybu 3; dost\u0119p 21 listopada 2026 r.).<\/li>\n    <li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/32973\" rel=\"nofollow\">IEC 61851-23:2023 (wydanie 2.0)<\/a> \u2014 Urz\u0105dzenia do zasilania pojazd\u00f3w elektrycznych pr\u0105dem sta\u0142ym (stacje pr\u0105du sta\u0142ego z wej\u015bciem pr\u0105du przemiennego i sta\u0142ego poza pojazdem; opublikowano 13.12.2023 r.; dost\u0119p 21 listopada 2026 r.).<\/li>\n    <li><a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2023\/1804\/2026-01-08\/eng\" rel=\"nofollow\">EUR-Lex \u2014 Rozporz\u0105dzenie (UE) 2023\/1804 (AFIR, ujednolicone 8 stycznia 2026 r.)<\/a> (Za\u0142\u0105cznik II \u00a7 1.1 Tryb 2 \u22643,7 kW IEC 60884-1:2022 wyj\u0105tek i artyku\u0142 5(1) p\u0142atne punkty publiczne) i <a href=\"https:\/\/www.gov.uk\/government\/publications\/the-public-charge-point-regulations-2023-guidance\/public-charge-point-regulations-2023-guidance\" rel=\"nofollow\">Rz\u0105d Wielkiej Brytanii \u2014 Wytyczne dotycz\u0105ce przepis\u00f3w dotycz\u0105cych punkt\u00f3w \u0142adowania publicznego z 2023 r.<\/a> (dost\u0119p 21 listopada 2026).<\/li>\n    <li><a href=\"https:\/\/www.electrical-installation.org\/enwiki\/Electric_Vehicle_and_EV_charging_fundamentals\" rel=\"nofollow\">Podr\u0119cznik instalacji elektrycznej Schneider Electric \u2014 Podstawy pojazd\u00f3w elektrycznych<\/a>, <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/EV_charging_station_design\" rel=\"nofollow\">Projekt stacji<\/a>, I <a href=\"https:\/\/www.electrical-installation.org\/enwiki\/EV_charging_-_electrical_installation_design\" rel=\"nofollow\">Projektowanie instalacji elektrycznych<\/a>; <a href=\"https:\/\/electrical.theiet.org\/bs-7671-18th-edition-wiring-regulations\/ensure-you-are-up-to-date-with-bs-7671\" rel=\"nofollow\">IET \u2014 BS 7671, wydanie 18, przepisy dotycz\u0105ce okablowania<\/a> &amp; <a href=\"https:\/\/electrical.theiet.org\/wiring-matters\/years\/2019\/76-july-2019\/latest-developments-in-international-standards-for-supplies-for-electric-vehicles\/\" rel=\"nofollow\">IET Wiring Matters \u2014 Mi\u0119dzynarodowe standardy zasilania pojazd\u00f3w elektrycznych<\/a>; <a href=\"https:\/\/www.sik.dk\/erhverv\/elinstallationer-og-elanlaeg\/vejledninger\/elinstallationer\/elbiler\/oplad-din-el-bil-sikkert\" rel=\"nofollow\">Du\u0144ski Urz\u0105d ds. Technologii Bezpiecze\u0144stwa (Sikkerhedsstyrelsen) \u2014 Wytyczne dotycz\u0105ce bezpiecznego \u0142adowania pojazd\u00f3w elektrycznych<\/a>; <a href=\"https:\/\/www.legrand.fr\/pro\/solutions\/prises-et-bornes-de-recharge-pour-vehicules-electriques-ensemble-vers-plus-de-mobilite-verte\" rel=\"nofollow\">Legrand \u2014 Dokumentacja gniazda Green&#039;Up EV<\/a>; I <a href=\"https:\/\/www.press.renault.co.uk\/releases\/502\" rel=\"nofollow\">Komunikat prasowy Renault UK \u2014 ZOE 43 kW z \u0142adowaniem pr\u0105dem zmiennym<\/a> (dost\u0119p 21 listopada 2026).<\/li>\n    <li><a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2594\" rel=\"nofollow\">ANSI\/UL 2594 (wyd. 3, 15.12.2022)<\/a>, <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2231-1\" rel=\"nofollow\">ANSI\/UL 2231-1 (wyd. 3, 06.11.2026)<\/a>, <a href=\"https:\/\/www.shopulstandards.com\/ProductDetail.aspx?productId=UL2231-2\" rel=\"nofollow\">UL 2231-2 (wersja z 15.12.2020)<\/a>, <a href=\"https:\/\/driveelectric.gov\/charging-connector\" rel=\"nofollow\">Wsp\u00f3lne Biuro Energii i Transportu \u2014 Z\u0142\u0105cze SAE J3400<\/a>, I <a href=\"https:\/\/afdc.energy.gov\/fuels\/electricity-stations\" rel=\"nofollow\">US DOE AFDC \u2014 Rozw\u00f3j infrastruktury do \u0142adowania pojazd\u00f3w elektrycznych<\/a> (dost\u0119p 21 listopada 2026).<\/li>\n    <li><a href=\"https:\/\/media.mennekes.org\/1367402_en_53674_originaldatei.pdf\" rel=\"nofollow\">Mennekes AMTRON Professional+ PnC 22 Karta techniczna<\/a> \u2014 patrz specyfikacje pomiarowe dla konfiguracji MID tr\u00f3jfazowej (dost\u0119p: 21 listopada 2026 r.).<\/li>\n    <li><a href=\"https:\/\/www.evb.com\/pl\/guides-videos\/\">Karty katalogowe urz\u0105dze\u0144 EVB<\/a> dla <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-Unsmart-Portable-AC-EV-Charger-2025.08.13.pdf\">BCPP-A1-16<\/a>, <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-Smart-Portable-Wall-mounted-AC-EV-Charger-2024.09.06.pdf\">inteligentne przeno\u015bne \u0142adowarki<\/a>, <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Wall-mounted-AC-EV-Charger-2024.09.06.pdf\">wallboxy pierwszej generacji<\/a>, <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-2nd-Generation-OCPP-Wall-mounted-AC-EV-Charger-2025.11.04.pdf\">wallboxy drugiej generacji<\/a>, <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Wall-mounted-Dual-Cable-AC-EV-Charger-Metal-Enclosure-2025.04.07.pdf\">Podw\u00f3jna skrzynka \u015bcienna BCPCM<\/a> I <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet-OCPP-Floor-mounted-AC-EV-Charger-2025.07.11.pdf\">Podstawa BCPCV serii N<\/a>. Zobacz <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2024\/02\/Floor-Mounted-AC-EV-Charger-0228.pdf\">Instrukcja instalacji BCPCV<\/a> dla ilustrowanej instalacji dwuwej\u015bciowej.<\/li>\n  <\/ul>\n<\/div>\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>EVB.COM &middot; Author: EVB Charging Solutions Team &middot; Updated November 2026 &middot; 18-minute read &middot; EV Charging Modes &middot; IEC 61851 &middot; AC &amp; DC Charging Mode 2 and Mode 3 both charge an EV with AC power. On a portable Mode 2 cable, the small box between the wall plug and the car is [&hellip;]<\/p>","protected":false},"author":3,"featured_media":42369,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[26],"tags":[486,484,485],"class_list":["post-44823","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-ac-ev-charging","tag-ev-charging-modes","tag-iec-61851"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB<\/title>\n<meta name=\"description\" content=\"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.evb.com\/pl\/mode-2-vs-mode-3-ev-charging\/\" \/>\n<meta property=\"og:locale\" content=\"pl_PL\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB\" \/>\n<meta property=\"og:description\" content=\"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.evb.com\/pl\/mode-2-vs-mode-3-ev-charging\/\" \/>\n<meta property=\"og:site_name\" content=\"EVB\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-21T08:49:33+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-21T08:49:45+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"720\" \/>\n\t<meta property=\"og:image:height\" content=\"720\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"EVB Editorial Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Napisane przez\" \/>\n\t<meta name=\"twitter:data1\" content=\"EVB Editorial Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Szacowany czas czytania\" \/>\n\t<meta name=\"twitter:data2\" content=\"22 minuty\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/\"},\"author\":{\"name\":\"EVB Editorial Team\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/person\\\/fe8f0137976034abdfd2ae4f8c5682d0\"},\"headline\":\"Mode 2 vs Mode 3 EV Charging: When to Use a Portable Charger or Wallbox\",\"datePublished\":\"2026-11-21T08:49:33+00:00\",\"dateModified\":\"2026-11-21T08:49:45+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/\"},\"wordCount\":4388,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/EVB-MODE-3-AC-EV-charger.webp\",\"keywords\":[\"AC EV Charging\",\"EV Charging Modes\",\"IEC 61851\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/\",\"url\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/\",\"name\":\"Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/EVB-MODE-3-AC-EV-charger.webp\",\"datePublished\":\"2026-11-21T08:49:33+00:00\",\"dateModified\":\"2026-11-21T08:49:45+00:00\",\"description\":\"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#breadcrumb\"},\"inLanguage\":\"pl-PL\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/EVB-MODE-3-AC-EV-charger.webp\",\"contentUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/06\\\/EVB-MODE-3-AC-EV-charger.webp\",\"width\":720,\"height\":720,\"caption\":\"EVB MODE 3 AC EV charger\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/mode-2-vs-mode-3-ev-charging\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.evb.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Mode 2 vs Mode 3 EV Charging: When to Use a Portable Charger or Wallbox\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#website\",\"url\":\"https:\\\/\\\/www.evb.com\\\/\",\"name\":\"EVB\",\"description\":\"Smart EV Charging &amp; Energy Storage Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.evb.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"pl-PL\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\",\"name\":\"EVB\",\"url\":\"https:\\\/\\\/www.evb.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/evb-3.png\",\"contentUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/evb-3.png\",\"width\":605,\"height\":626,\"caption\":\"EVB\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/person\\\/fe8f0137976034abdfd2ae4f8c5682d0\",\"name\":\"EVB Editorial Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"pl-PL\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"caption\":\"EVB Editorial Team\"},\"description\":\"The EVB Editorial Team creates expert content on EV charging infrastructure, commercial charging solutions, energy storage integration, and global charging projects, with input from EVB product and engineering specialists.\",\"sameAs\":[\"https:\\\/\\\/www.evb.com\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB","description":"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.evb.com\/pl\/mode-2-vs-mode-3-ev-charging\/","og_locale":"pl_PL","og_type":"article","og_title":"Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB","og_description":"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.","og_url":"https:\/\/www.evb.com\/pl\/mode-2-vs-mode-3-ev-charging\/","og_site_name":"EVB","article_published_time":"2026-11-21T08:49:33+00:00","article_modified_time":"2026-11-21T08:49:45+00:00","og_image":[{"width":720,"height":720,"url":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp","type":"image\/webp"}],"author":"EVB Editorial Team","twitter_card":"summary_large_image","twitter_misc":{"Napisane przez":"EVB Editorial Team","Szacowany czas czytania":"22 minuty"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#article","isPartOf":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/"},"author":{"name":"EVB Editorial Team","@id":"https:\/\/www.evb.com\/#\/schema\/person\/fe8f0137976034abdfd2ae4f8c5682d0"},"headline":"Mode 2 vs Mode 3 EV Charging: When to Use a Portable Charger or Wallbox","datePublished":"2026-11-21T08:49:33+00:00","dateModified":"2026-11-21T08:49:45+00:00","mainEntityOfPage":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/"},"wordCount":4388,"commentCount":0,"publisher":{"@id":"https:\/\/www.evb.com\/#organization"},"image":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#primaryimage"},"thumbnailUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp","keywords":["AC EV Charging","EV Charging Modes","IEC 61851"],"articleSection":["Blog"],"inLanguage":"pl-PL","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/","url":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/","name":"Mode 2 vs Mode 3 EV Charging: Portable or Wallbox? | EVB","isPartOf":{"@id":"https:\/\/www.evb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#primaryimage"},"image":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#primaryimage"},"thumbnailUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp","datePublished":"2026-11-21T08:49:33+00:00","dateModified":"2026-11-21T08:49:45+00:00","description":"Compare Mode 2 portable IC-CPD chargers vs Mode 3 fixed wallboxes under IEC 61851-1, IEC 62752:2024, IEC 60364-7-722, and EU AFIR: sockets, RCDs, and selection.","breadcrumb":{"@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#breadcrumb"},"inLanguage":"pl-PL","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/"]}]},{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#primaryimage","url":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp","contentUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/06\/EVB-MODE-3-AC-EV-charger.webp","width":720,"height":720,"caption":"EVB MODE 3 AC EV charger"},{"@type":"BreadcrumbList","@id":"https:\/\/www.evb.com\/mode-2-vs-mode-3-ev-charging\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.evb.com\/"},{"@type":"ListItem","position":2,"name":"Mode 2 vs Mode 3 EV Charging: When to Use a Portable Charger or Wallbox"}]},{"@type":"WebSite","@id":"https:\/\/www.evb.com\/#website","url":"https:\/\/www.evb.com\/","name":"EVB","description":"Smart EV Charging &amp; Energy Storage Solutions","publisher":{"@id":"https:\/\/www.evb.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.evb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"pl-PL"},{"@type":"Organization","@id":"https:\/\/www.evb.com\/#organization","name":"EVB","url":"https:\/\/www.evb.com\/","logo":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/www.evb.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.evb.com\/wp-content\/uploads\/2021\/03\/evb-3.png","contentUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2021\/03\/evb-3.png","width":605,"height":626,"caption":"EVB"},"image":{"@id":"https:\/\/www.evb.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.evb.com\/#\/schema\/person\/fe8f0137976034abdfd2ae4f8c5682d0","name":"EVB Editorial Team","image":{"@type":"ImageObject","inLanguage":"pl-PL","@id":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","caption":"EVB Editorial Team"},"description":"The EVB Editorial Team creates expert content on EV charging infrastructure, commercial charging solutions, energy storage integration, and global charging projects, with input from EVB product and engineering specialists.","sameAs":["https:\/\/www.evb.com\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.evb.com\/pl\/wp-json\/wp\/v2\/posts\/44823","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.evb.com\/pl\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.evb.com\/pl\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.evb.com\/pl\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.evb.com\/pl\/wp-json\/wp\/v2\/comments?post=44823"}],"version-history":[{"count":2,"href":"https:\/\/www.evb.com\/pl\/wp-json\/wp\/v2\/posts\/44823\/revisions"}],"predecessor-version":[{"id":44827,"href":"https:\/\/www.evb.com\/pl\/wp-json\/wp\/v2\/posts\/44823\/revisions\/44827"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.evb.com\/pl\/wp-json\/wp\/v2\/media\/42369"}],"wp:attachment":[{"href":"https:\/\/www.evb.com\/pl\/wp-json\/wp\/v2\/media?parent=44823"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.evb.com\/pl\/wp-json\/wp\/v2\/categories?post=44823"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.evb.com\/pl\/wp-json\/wp\/v2\/tags?post=44823"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}