{"id":44861,"date":"2026-11-25T13:05:41","date_gmt":"2026-11-25T05:05:41","guid":{"rendered":"https:\/\/www.evb.com\/?p=44861"},"modified":"2026-11-25T13:05:50","modified_gmt":"2026-11-25T05:05:50","slug":"pull-through-ev-charging-station-design","status":"publish","type":"post","link":"https:\/\/www.evb.com\/ro\/pull-through-ev-charging-station-design\/","title":{"rendered":"Proiectarea sta\u021biilor de \u00eenc\u0103rcare cu trecere direct\u0103: dimensiuni, amplasare &amp; echipamente DC separate pentru camioane &amp; vehicule cu remorc\u0103"},"content":{"rendered":"<style>\n.evb-pullthrough-article{font-family:inherit;color:#1f1f1f;font-size:17px;line-height:1.8;overflow-wrap:break-word}\n.evb-pullthrough-article h2,.evb-pullthrough-article h3{color:#0b2239;line-height:1.3}\n.evb-pullthrough-article h2{font-size:30px;font-weight:800;margin:44px 0 14px}\n.evb-pullthrough-article h3{font-size:22px;font-weight:700;margin:26px 0 10px}\n.evb-pullthrough-article p{margin:0 0 18px;color:#3f4852}\n.evb-pullthrough-article a{color:#185fa5;text-decoration:underline;text-underline-offset:2px}\n.evb-pullthrough-article a:focus-visible,.evb-pullthrough-article .evb-table-wrap:focus-visible{outline:2px solid #185fa5;outline-offset:3px}\n.evb-pullthrough-article .evb-eeat-line{margin:0 0 26px;color:#667584;font-size:15px;line-height:1.7}\n.evb-pullthrough-article .evb-article-intro{border-left:4px solid #185fa5;background:#f4f8fc;padding:16px 20px;border-radius:0 8px 8px 0;margin:0 0 24px;font-size:17.5px;line-height:1.72;color:#172b3e}\n.evb-pullthrough-article .evb-example-box{background:#f0f7fb;border:1px solid #cce0ee;border-radius:8px;padding:15px 18px;margin:0 0 22px;font-size:16px;color:#163146}\n.evb-pullthrough-article ul,.evb-pullthrough-article ol{margin:0 0 18px 22px;padding:0}\n.evb-pullthrough-article li{margin:0 0 9px;color:#3f4852}\n.evb-pullthrough-article .evb-table-title{margin:20px 0 8px;color:#0b2239;font-weight:700;font-size:15.5px;line-height:1.45}\n.evb-pullthrough-article .evb-table-wrap{max-width:100%;overflow-x:auto;margin:0 0 12px;-webkit-overflow-scrolling:touch}\n.evb-pullthrough-article .evb-table{width:100%;min-width:620px;border-collapse:collapse;font-size:15px}\n.evb-pullthrough-article .evb-table th,.evb-pullthrough-article .evb-table td{border:1px solid #dfe6ed;padding:11px 13px;text-align:left;vertical-align:top}\n.evb-pullthrough-article .evb-table thead th{background:#0b2239;color:#fff;font-size:13.5px;letter-spacing:.02em}\n.evb-pullthrough-article .evb-table tbody th{background:#f7fafe;color:#0b2239;font-weight:700}\n.evb-pullthrough-article .evb-table tbody tr:nth-child(even) td{background:#fafcfe}\n.evb-pullthrough-article .evb-table-note{font-size:13px;color:#526171;margin:0 0 24px}\n.evb-pullthrough-article .evb-checklist{background:#f7f9fc;border:1px solid #d9e3ee;border-radius:8px;padding:18px 22px;margin:22px 0 26px}\n.evb-pullthrough-article .evb-checklist h3,.evb-pullthrough-article .evb-callout h3{margin-top:0}\n.evb-pullthrough-article .evb-checklist>:last-child,.evb-pullthrough-article .evb-callout>:last-child{margin-bottom:0}\n.evb-pullthrough-article .evb-callout{background:#0b2239;color:#fff;border-radius:10px;padding:24px 26px;margin:32px 0}\n.evb-pullthrough-article .evb-callout h3,.evb-pullthrough-article .evb-callout p{color:#f1f6fb}\n.evb-pullthrough-article .evb-callout a{color:#9fd4ff;font-weight:600}\n.evb-pullthrough-article .evb-cta-btn{display:inline-block;margin-top:8px;background:#185fa5;color:#fff!important;text-decoration:none!important;padding:11px 22px;border-radius:7px;font-weight:700}\n.evb-pullthrough-article .evb-cta-btn:hover{background:#124c85}\n.evb-pullthrough-article .evb-article-figure{max-width:920px;margin:24px 0 28px}\n.evb-pullthrough-article .evb-article-figure a{display:block}\n.evb-pullthrough-article .evb-article-figure img{display:block;width:100%;height:auto;border-radius:10px;border:1px solid #dce5ee}\n.evb-pullthrough-article figcaption{margin-top:9px;color:#526171;font-size:.88em;line-height:1.55}\n@media(max-width:768px){\n  .evb-pullthrough-article{font-size:16px}\n  .evb-pullthrough-article h2{font-size:24px;margin:34px 0 12px}\n  .evb-pullthrough-article h3{font-size:19px}\n}\n<\/style>\n<div class=\"evb-article-wrap evb-pullthrough-article\" lang=\"en\">\n  <div class=\"evb-eeat-line\">EVB.COM &middot; Autor: echipa EVB pentru solu\u021bii de \u00eenc\u0103rcare &middot; Actualizat \u00een noiembrie 2026 &middot; Timp de lectur\u0103: 15 minute &middot; \u00cenc\u0103rcarea vehiculelor electrice cu trecere direct\u0103 &middot; \u00cenc\u0103rcare rapid\u0103 comercial\u0103 DC &middot; Camioane electrice<\/div>\n\n  <p class=\"evb-article-intro\"><strong>O sta\u021bie de \u00eenc\u0103rcare cu trecere direct\u0103 permite camioanelor electrice \u0219i ansamblurilor cu remorc\u0103 s\u0103 intre \u0219i s\u0103 ias\u0103 \u00een linie dreapt\u0103, f\u0103r\u0103 decuplarea remorcii sau mers \u00eenapoi.<\/strong> Dimensiona\u021bi fiecare loc drept de la lungimea efectiv\u0103 a vehiculului de proiectare, cu rezerve de oprire definite \u00een fa\u021b\u0103 \u0219i \u00een spate. Verifica\u021bi separat abaterea remorcii spre interiorul curbei, balansul extremit\u0103\u021bii din spate \u0219i racordurile intr\u0103rii \u0219i ie\u0219irii. Pentru locurile accesibile cu trecere direct\u0103 din Statele Unite, U.S. Access Board recomand\u0103 cel pu\u021bin <strong>16 ft (4,880 mm)<\/strong> l\u0103\u021bime \u0219i un cablu care se poate conecta la un vehicul aflat la <strong>5 ft (1,525 mm)<\/strong> distan\u021b\u0103. Separarea dulapurilor redresoare DC de terminalele compacte de pe insul\u0103 las\u0103 echipamentele voluminoase de conversie \u00een afara insulelor \u00eenguste.<\/p>\n\n  <p>Locurile conven\u021bionale pentru autoturisme, cu intrare cu fa\u021ba sau cu spatele, devin insuficiente c\u00e2nd sose\u0219te un pick-up electric cu remorc\u0103 sau un camion articulat de marf\u0103. \u0218oferii ocup\u0103 mai multe locuri, blocheaz\u0103 c\u0103ile de circula\u021bie sau ocolesc sta\u021bia. Acest ghid trateaz\u0103 calculul dimensiunilor, circula\u021bia cu sens unic, geometria accesibilit\u0103\u021bii, protec\u021bia la impact, verificarea zonelor mixte \u0219i alegerea echipamentelor DC separate.<\/p>\n\n  <div class=\"evb-example-box\"><strong>Ce echipamente se monteaz\u0103 pe insula de \u00eenc\u0103rcare?<\/strong> La un \u00eenc\u0103rc\u0103tor integrat, modulele de putere \u0219i comenzile sunt montate \u00een aceea\u0219i carcas\u0103. Echipamentul de 720 kW de la EVB <strong>BSDC720-250D5<\/strong> folose\u0219te un dulap redresor separat \u0219i terminale de \u00eenc\u0103rcare. Pute\u021bi a\u0219eza dulapul de <strong>1,700 &times; 1,000 &times; 2,150 mm<\/strong> (&le;1,100 kg) pe o platform\u0103 separat\u0103 \u0219i instala doar terminalul de <strong>600 &times; 230 &times; 1,700 mm<\/strong> (&le;110 kg) pe insul\u0103. La dimensionare, lua\u021bi \u00een calcul funda\u021bia, st\u00e2lpii de protec\u021bie, deschiderea u\u0219ilor dulapului \u0219i spa\u021biul pentru interven\u021biile tehnicienilor.<\/div>\n\n  <p>Pentru celelalte aspecte ale proiectului, consulta\u021bi ghidurile EVB despre <a href=\"https:\/\/www.evb.com\/ro\/ada-ev-charging-requirements\/\">\u00eenc\u0103rcarea accesibil\u0103 a vehiculelor electrice<\/a>, <a href=\"https:\/\/www.evb.com\/ro\/ev-charging-station-signage\/\">semnalizarea sta\u021biilor<\/a>, <a href=\"https:\/\/www.evb.com\/ro\/ev-charger-cable-management\/\">gestionarea cablurilor pentru \u00eenc\u0103rc\u0103toare comerciale<\/a>\u0219i <a href=\"https:\/\/www.evb.com\/ro\/fleet-depot-charging-power-requirements\/\">cerin\u021bele electrice pentru bazele de flote<\/a>.<\/p>\n\n  <h2 id=\"when-pull-through-bays-are-required\">1. C\u00e2nd se aleg locuri cu trecere direct\u0103 \u00een locul intr\u0103rii cu spatele<\/h2>\n\n  <p>Fiecare band\u0103 cu trecere direct\u0103 necesit\u0103 trasee continue de intrare \u0219i ie\u0219ire, \u00een loc de un singur culoar \u00eenfundat. Fiecare loc de \u00eenc\u0103rcare cu trecere direct\u0103 ocup\u0103 astfel mai mult\u0103 suprafa\u021b\u0103 pavat\u0103 dec\u00e2t un loc perpendicular obi\u0219nuit. Stabili\u021bi num\u0103rul de locuri pornind de la cererea din amplasament, f\u0103r\u0103 un procent fix:<\/p>\n\n  <ul>\n    <li><strong>Dimensionarea locurilor dup\u0103 cererea de v\u00e2rf:<\/strong> Calcula\u021bi ponderea benzilor cu trecere direct\u0103 din num\u0103rul maxim estimat de sosiri pe or\u0103 ale camioanelor \u0219i vehiculelor cu remorc\u0103, durata medie de \u00eenc\u0103rcare \u0219i timpul maxim de a\u0219teptare vizat. Popasurile de pe autostrad\u0103 pentru remorci de agrement \u0219i coridoarele de marf\u0103 necesit\u0103 o pondere mai mare dec\u00e2t parc\u0103rile comerciale urbane.<\/li>\n    <li><strong>Adaptarea bazelor logistice la ciclul de exploatare:<\/strong> Locurile cu trecere direct\u0103 \u0219i sens unic faciliteaz\u0103 \u00eenc\u0103rcarea de oportunitate \u00een timpul schimbului, \u00een sesiuni de 30\u201390 de minute. Bazele cu sta\u021bionare \u00eendelungat\u0103 peste noapte pot p\u0103stra \u0219i locuri cu intrare \u00eenainte ori cu spatele dac\u0103 au zone de manevr\u0103 sau personal de ghidare.<\/li>\n    <li><strong>Prevenirea bloc\u0103rii pe benzile \u00een tandem cu sens unic:<\/strong> Pe o band\u0103 \u00een tandem cu sens unic, f\u0103r\u0103 posibilitatea de ocolire, <strong>dac\u0103 vehiculul din spate termin\u0103 primul \u00eenc\u0103rcarea, trebuie s\u0103 a\u0219tepte plecarea celui din fa\u021b\u0103<\/strong> \u00eenainte de a ie\u0219i, \u00een timp ce vehiculul din fa\u021b\u0103 poate pleca drept. Prevede\u021bi pentru fiecare loc public cu trecere direct\u0103 o ie\u0219ire dreapt\u0103 independent\u0103 ori o band\u0103 de ocolire.<\/li>\n    <li><strong>Coordonarea din timp a zonelor de alimentare cu carburant \u0219i \u00eenc\u0103rcare electric\u0103:<\/strong> Dac\u0103 pe amplasament exist\u0103 \u0219i pompe de motorin\u0103 sau benzin\u0103, indica\u021bi zonele periculoase asociate carburan\u021bilor lichizi \u0219i traseele de a\u0219teptare pentru vehiculele grele \u00eenainte de stabilirea locurilor de \u00eenc\u0103rcare.<\/li>\n  <\/ul>\n\n  <h2 id=\"pull-through-bay-dimensions-and-site-geometry\">2. Organizarea sta\u021biei cu trecere direct\u0103 \u0219i dimensiunile locurilor<\/h2>\n\n  <p>Un singur set de dimensiuni nu se potrive\u0219te tuturor vehiculelor \u0219i jurisdic\u021biilor. \u00cen loc s\u0103 prelua\u021bi dimensiuni generice, calcula\u021bi lungimea locului drept pe baza unui ansamblu de vehicule definit \u0219i a rezervelor de oprire: <strong>Lungimea locului drept = lungimea total\u0103 a vehiculului de proiectare + rezerva de oprire din fa\u021b\u0103 + spa\u021biul liber din spate<\/strong>. Simula\u021bi apoi separat anvelopa traiectoriei, de exemplu cu AutoTURN, pentru a verifica abaterea remorcii spre interior, balansul consolei din spate \u0219i racordurile de la intrare \u0219i ie\u0219ire.<\/p>\n\n  <figure class=\"evb-article-figure\">\n    <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/pull-through-ev-charging-bay-geometry-plan-v2.webp\" target=\"_blank\" rel=\"noopener\" title=\"Deschide\u021bi la rezolu\u021bie complet\u0103 planul de circula\u021bie \u0219i virare al sta\u021biei cu trecere direct\u0103\">\n      <img src=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/pull-through-ev-charging-bay-geometry-plan-v2.webp\" alt=\"Plan de circula\u021bie f\u0103r\u0103 text, v\u0103zut de sus, cu benzi cu trecere direct\u0103 \u00een sens unic de la st\u00e2nga la dreapta pentru un pick-up cu remorc\u0103 \u0219i un camion articulat care \u00eempart o insul\u0103 \u00eengust\u0103. Reperele 1\u20136 indic\u0103 alinierea vehiculelor \u0219i ie\u0219irea, anvelopa de virare a remorcii, distan\u021ba lateral\u0103 de la vehicul la terminal \u0219i traseul cablului la priz\u0103, st\u00e2lpii din lateral, platforma dulapului redresor din afara insulei \u0219i tubulatura DC subteran\u0103.\" width=\"1600\" height=\"900\" loading=\"lazy\" decoding=\"async\" \/>\n    <\/a>\n    <figcaption>Plan \u00een vedere de sus pentru trecere direct\u0103 cu sens unic (p\u0103r\u021bile frontale ale vehiculelor, s\u0103ge\u021bile \u0219i traseele de ie\u0219ire sunt orientate de la st\u00e2nga la dreapta). Repere: <strong>&#9312;<\/strong> intrare cu sens unic, loc de \u00eenc\u0103rcare drept \u0219i ie\u0219ire dreapt\u0103 independent\u0103 (f\u0103r\u0103 blocare \u00een tandem); <strong>&#9313;<\/strong> anvelop\u0103 de virare verificat\u0103 separat pentru abaterea remorcii spre interior \u0219i balansul extremit\u0103\u021bii din spate; <strong>&#9314;<\/strong> distan\u021ba lateral\u0103 \u00eentre vehicul \u0219i terminal (U.S. Access Board recomand\u0103 racordarea la un vehicul aflat la 5 ft \/ 1,525 mm), cu traseul cablului p\u00e2n\u0103 la priza real\u0103 a vehiculului; <strong>&#9315;<\/strong> st\u00e2lpi de protec\u021bie alinia\u021bi de o parte \u0219i de alta a terminalelor DC compacte de pe insul\u0103; <strong>&#9316;<\/strong> platforma dulapului redresor modular, \u00een afara insulei; <strong>&#9317;<\/strong> tubulatur\u0103 subteran\u0103 de alimentare DC. Lungimile \u0219i l\u0103\u021bimile exacte depind de calculul pentru vehiculul de proiectare \u0219i de normele locale din tabel.<\/figcaption>\n  <\/figure>\n\n  <p class=\"evb-table-title\" id=\"tbl-dimensions-title\">Exemple de calcul pentru locuri cu trecere direct\u0103 &amp; criterii de verificare a lucr\u0103rilor civile (dimensiuni neprescriptive)<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-dimensions-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">Verificare de proiectare<\/th>\n          <th scope=\"col\">Exemplul A: pick-up u\u0219or + remorc\u0103 de marf\u0103<\/th>\n          <th scope=\"col\">Exemplul B: camion articulat de 16.5 m \u00een UE (<a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/1996\/53\/oj\/eng\" rel=\"nofollow\" style=\"color:#9fd4ff\">Dir. 96\/53\/EC<\/a>)<\/th>\n          <th scope=\"col\">Exemplul C: cap tractor din Statele Unite + semiremorc\u0103 de 53 ft<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\">Ansamblul de vehicule ales (lungime total\u0103)<\/th>\n          <td>Exemplu de 50 ft (15.2 m) (pick-up de ~20 ft + remorc\u0103 ata\u0219at\u0103 de 30 ft; recalcula\u021bi dac\u0103 ansamblul dep\u0103\u0219e\u0219te 50 ft)<\/td>\n          <td>16.50 m (54.1 ft), lungimea maxim\u0103 a vehiculului articulat, conform anexei I la Directiva 96\/53\/EC (trenuri rutiere de p\u00e2n\u0103 la 18.75 m)<\/td>\n          <td>~73.5 ft (22.4 m) pentru un ansamblu interstatal tipic cu cap tractor \u0219i semiremorc\u0103 de 53 ft (verifica\u021bi limitele de lungime ale fiec\u0103rui stat)<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Lungimea calculat\u0103 a locului drept (vehicul + rezerve fa\u021b\u0103 \u0219i spate)<\/th>\n          <td><strong>60 ft (18.3 m)<\/strong> = ansamblu de 50 ft + rezerv\u0103 de oprire fa\u021b\u0103 de 5 ft + spa\u021biu liber spate de 5 ft (recalcula\u021bi pentru remorci mai lungi)<\/td>\n          <td><strong>21.5 m (~70.5 ft)<\/strong> = camion de 16.5 m + rezerv\u0103 fa\u021b\u0103 de 2.5 m + spa\u021biu liber spate de 2.5 m (m\u0103ri\u021bi pentru trenuri rutiere de 18.75 m)<\/td>\n          <td><strong>93.5 ft (~28.5 m)<\/strong> = ansamblu de 73.5 ft + rezerv\u0103 fa\u021b\u0103 de 10 ft + spa\u021biu liber spate de 10 ft; ad\u0103uga\u021bi tangente separate la intrare \u0219i ie\u0219ire<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">L\u0103\u021bimea locului &amp; cerin\u021bele regionale de accesibilitate<\/th>\n          <td>Loc accesibil cu trecere direct\u0103 \u00een Statele Unite: <strong>&ge;16 ft (4,880 mm)<\/strong> conform <a href=\"https:\/\/www.access-board.gov\/tad\/ev\/#pull-through-ev-charging-stations-design\" rel=\"nofollow\">U.S. Access Board<\/a>. \u00cen afara Statelor Unite, aplica\u021bi normele na\u021bionale pentru benzi \u0219i accesibilitate.<\/td>\n          <td>Aplica\u021bi l\u0103\u021bimile de band\u0103 na\u021bionale pentru vehicule grele \u0219i normele locale de accesibilitate \u00een UE. Recomandarea SUA de 16 ft nu se aplic\u0103 uniform \u00een Europa.<\/td>\n          <td>Loc accesibil cu trecere direct\u0103 \u00een Statele Unite: <strong>&ge;16 ft (4,880 mm)<\/strong> conform U.S. Access Board; confirma\u021bi degaj\u0103ri mai mari c\u00e2nd oglinzile sau treptele cabinelor vehiculelor grele le impun.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Gabarit vertical liber (copertin\u0103, iluminat &amp; bra\u021be de cabluri)<\/th>\n          <td>Verifica\u021bi autorulotele \u00eenalte, portbagajele de plafon \u0219i cea mai joas\u0103 grind\u0103 a copertinei sau cel mai jos bra\u021b suspendat pentru cablu.<\/td>\n          <td>Peste \u00een\u0103l\u021bimea legal\u0103 de 4.00 m din UE (Directiva 96\/53\/EC, anexa I), ad\u0103uga\u021bi marja local\u0103 de siguran\u021b\u0103 pentru pod sau copertin\u0103 \u0219i gabaritul echipamentelor suspendate.<\/td>\n          <td><strong>Nu exist\u0103 o limit\u0103 federal\u0103 uniform\u0103 de \u00een\u0103l\u021bime pentru vehiculele comerciale \u00een Statele Unite<\/strong> (<a href=\"https:\/\/ops.fhwa.dot.gov\/freight\/publications\/size_regs_final_rpt\/index.htm\" rel=\"nofollow\">FHWA<\/a>); verifica\u021bi limitele statelor (de obicei 13.5\u201314 ft), traseele deservite, vehiculele vizate \u0219i cel mai jos element al copertinei.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">Virarea &amp; verificarea anvelopei traiectoriei<\/th>\n          <td>Modela\u021bi cu un program de traiectorii abaterea remorcii spre interior \u0219i balansul din spate, de la bordura cobor\u00e2t\u0103 p\u00e2n\u0103 la ie\u0219ire.<\/td>\n          <td>Directiva 96\/53\/EC, anexa I &sect;1.5, define\u0219te capacitatea de virare a vehiculului (<strong>raz\u0103 exterioar\u0103 de 12.50 m \/ raz\u0103 interioar\u0103 de 5.30 m<\/strong>), adic\u0103 o caracteristic\u0103 a vehiculului, <em>nu<\/em> raza curbei \u00een amplasament. Proiecta\u021bi curbe mai largi pentru o degajare sigur\u0103.<\/td>\n          <td>Modela\u021bi \u00een AutoTURN sau \u00eentr-un program echivalent abaterea aferent\u0103 ampatamentului exact al ansamblului, consola exterioar\u0103 din fa\u021b\u0103 \u0219i racordurile la intrare \u0219i la ie\u0219ire.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">Exemplele arat\u0103 cum rezult\u0103 lungimea locului din geometria vehiculului ales \u0219i din rezervele explicite. \u00cenainte de lucr\u0103ri, verifica\u021bi limitele statale \u0219i na\u021bionale de dimensiuni ale vehiculelor (<a href=\"https:\/\/ops.fhwa.dot.gov\/freight\/publications\/size_regs_final_rpt\/index.htm\" rel=\"nofollow\">FHWA: dimensiuni &amp; mase<\/a>; <a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/1996\/53\/oj\/eng\" rel=\"nofollow\">Directiva 96\/53\/EC<\/a>), <a href=\"https:\/\/driveelectric.gov\/\" rel=\"nofollow\">U.S. Joint Office<\/a> ), orient\u0103rile institu\u021biei \u0219i \u0219abloanele de anvelop\u0103 aplicabile.<\/p>\n\n  <h3>Reguli pentru circula\u021bie, a\u0219teptare &amp; semnalizare<\/h3>\n  <ul>\n    <li><strong>Circula\u021bie strict \u00een sens unic:<\/strong> Utiliza\u021bi s\u0103ge\u021bi cu contrast ridicat pe pavaj, linii de oprire \u00een dreptul zonelor tipice ale prizelor \u0219i semnalizare direc\u021bional\u0103 clar\u0103 \u00een conformitate cu <a href=\"https:\/\/mutcd.fhwa.dot.gov\/\" rel=\"nofollow\">FHWA MUTCD<\/a>pentru a preveni \u00eentoarcerile sau manevrele \u00een mar\u0219arier f\u0103r\u0103 vizibilitate sub copertin\u0103.<\/li>\n    <li><strong>Dimensionarea benzilor de a\u0219teptare \u00een afara drumului principal:<\/strong> Rezerva\u021bi un spa\u021biu de a\u0219teptare \u00een incint\u0103 \u00eenaintea locurilor de \u00eenc\u0103rcare, mai ales pe coridoarele de marf\u0103, astfel \u00eenc\u00e2t camioanele care a\u0219teapt\u0103 s\u0103 nu ajung\u0103 pe bretelele autostr\u0103zii sau pe benzile adiacente.<\/li>\n    <li><strong>Montarea st\u00e2lpilor copertinei \u00een afara anvelopei traiectoriei:<\/strong> Alinia\u021bi st\u00e2lpii copertinei cu insulele terminalelor, nu cu col\u021burile intr\u0103rii \u00een band\u0103, unde abaterea spre interior a axei din spate a remorcii poate lovi st\u00e2lpii de o\u021bel expu\u0219i.<\/li>\n  <\/ul>\n\n  <h2 id=\"island-protection-accessibility-and-fuel-separation\">3. Accesibilitate, protec\u021bie la impact &amp; verificarea zonelor mixte<\/h2>\n\n  <p>Insulele cu trecere direct\u0103 reunesc cerin\u021bele de accesibilitate, protec\u021bie la impactul vehiculelor \u0219i, \u00een popasurile cu mai multe tipuri de carburant, clasificarea zonelor cu vapori inflamabili. Analiza\u021bi separat fiecare cerin\u021b\u0103, f\u0103r\u0103 a confunda dimensiunile prev\u0103zute de norme diferite.<\/p>\n\n  <figure class=\"evb-article-figure\">\n    <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/pull-through-island-clearance-and-protection-section-v2.webp\" target=\"_blank\" rel=\"noopener\" title=\"Deschide\u021bi la rezolu\u021bie complet\u0103 schema de apropiere accesibil\u0103 \u0219i raz\u0103 a cablului\">\n      <img src=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/pull-through-island-clearance-and-protection-section-v2.webp\" alt=\"Schem\u0103 tehnic\u0103 f\u0103r\u0103 text care arat\u0103 apropierea unei persoane \u00een scaun rulant de un terminal DC separat, la nivelul pavajului, l\u00e2ng\u0103 o band\u0103 cu trecere direct\u0103. Reperele 1\u20135 marcheaz\u0103 spa\u021biul liber la sol, apropierea frontal\u0103 sau paralel\u0103, \u00een\u0103l\u021bimea de acces la ecran \u0219i suport, st\u00e2lpii de protec\u021bie laterali \u0219i cablul de la ie\u0219irea terminalului la priza vehiculului.\" width=\"1600\" height=\"900\" loading=\"lazy\" decoding=\"async\" \/>\n    <\/a>\n    <figcaption>Verificarea apropierii accesibile \u0219i a razei cablului pe o insul\u0103 la nivelul pavajului. Repere: <strong>&#9312;<\/strong> suprafa\u021b\u0103 liber\u0103 la acela\u0219i nivel (ADA &sect;305), f\u0103r\u0103 borduri \u00eenalte sau cu bordur\u0103 cobor\u00e2t\u0103 la nivel; <strong>&#9313;<\/strong> apropiere frontal\u0103 ori paralel\u0103 a scaunului rulant, verificat\u0103 separat \u00een func\u021bie de ad\u00e2ncimea oric\u0103rui obstacol; <strong>&#9314;<\/strong> zona de acces la afi\u0219aj, cititorul de pl\u0103\u021bi \u0219i suportul conectorului (ADA &sect;308); <strong>&#9315;<\/strong> st\u00e2lpi laterali de o\u021bel care protejeaz\u0103 terminalul f\u0103r\u0103 a bloca suprafa\u021ba liber\u0103 din fa\u021b\u0103 sau accesul la comenzi; <strong>&#9316;<\/strong> cablul urmeaz\u0103 traseul de la ie\u0219irea terminalului la priza vehiculului, \u021bin\u00e2nd cont de cursa mecanismului de retragere. Verifica\u021bi raza de ac\u021biune \u00een pozi\u021bia de oprire, cu toleran\u021ba la parcare (U.S. Access Board recomand\u0103 conectarea la un vehicul aflat la 5 ft \/ 1,525 mm).<\/figcaption>\n  <\/figure>\n\n  <h3>Cele trei recomand\u0103ri distincte ale U.S. Access Board &amp; verific\u0103rile din capitolul 3 ADA<\/h3>\n  <p><a href=\"https:\/\/www.access-board.gov\/tad\/ev\/#pull-through-ev-charging-stations-design\" rel=\"nofollow\">Ghidul U.S. Access Board privind \u00eenc\u0103rcarea cu trecere direct\u0103<\/a> prevede trei verific\u0103ri separate pentru proiectan\u021bi:<\/p>\n  <ul>\n    <li><strong>Marcajele:<\/strong> Sta\u021biile de \u00eenc\u0103rcare cu trecere direct\u0103 nu necesit\u0103 trasarea sau marcarea individual\u0103 a locurilor de \u00eenc\u0103rcare.<\/li>\n    <li><strong>L\u0103\u021bimea locului:<\/strong> Asigura\u021bi cel pu\u021bin <strong>16 ft (4,880 mm)<\/strong> l\u0103\u021bime pentru locul de \u00eenc\u0103rcare. (Aceasta este recomandarea U.S. Access Board. \u00cen Europa \u0219i \u00een alte \u021b\u0103ri se respect\u0103 normele locale de accesibilitate.)<\/li>\n    <li><strong>Raza de racordare:<\/strong> Cablurile de \u00eenc\u0103rcare trebuie s\u0103 se poat\u0103 conecta la un vehicul aflat la <strong>5 ft (1,525 mm)<\/strong> distan\u021b\u0103.<\/li>\n  <\/ul>\n\n  <p>Separat, \u00een temeiul <a href=\"https:\/\/www.access-board.gov\/ada\/chapter\/ch03\/#308-reach-ranges\" rel=\"nofollow\">capitolului 3 din standardele ADA (&sect;305 \u0219i &sect;308)<\/a>, terminalele accesibile necesit\u0103 o <strong>suprafa\u021b\u0103 liber\u0103 la sol (&sect;305)<\/strong>f\u0103r\u0103 obstacole, de preferat f\u0103r\u0103 borduri \u00eenalte sau cu un acces cobor\u00e2t la nivel, precum \u0219i verificarea <strong>direc\u021biei de apropiere<\/strong> (frontal\u0103 ori paralel\u0103), a <strong>ad\u00e2ncimii de acces peste orice obstacol<\/strong>\u0219i <strong>\u00een\u0103l\u021bimii comenzilor (&sect;308)<\/strong> (maximum 48 in \/ 1,220 mm pentru acces frontal sau paralel neobstruc\u021bionat; limita de \u00een\u0103l\u021bime depinde de apropiere \u0219i de ad\u00e2ncimea obstacolului). C\u00e2nd autorit\u0103\u021bile locale de incendiu aplic\u0103 <strong>sec\u021biunea 312 din IFC<\/strong>, st\u00e2lpii de protec\u021bie prescri\u0219i (IFC &sect;312.2: \u021beav\u0103 de o\u021bel umplut\u0103 cu beton de &ge;4 in \/ 102 mm, interax &le;4 ft, \u00eencastrare de cel pu\u021bin 3 ft (914 mm) \u00een funda\u021bii de beton cu diametrul de minimum 15 in (381 mm), \u00een\u0103l\u021bime &ge;3 ft \u0219i distan\u021b\u0103 orizontal\u0103 &ge;3 ft p\u00e2n\u0103 la obiectul protejat) guverneaz\u0103 protec\u021bia orizontal\u0103. ADA &sect;305\/&sect;308 reglementeaz\u0103 spa\u021biul liber, orientarea de apropiere, ad\u00e2ncimea de acces \u0219i \u00een\u0103l\u021bimea comenzilor pentru scaune rulante. Verifica\u021bi toate cele patru elemente ADA \u00een paralel cu protec\u021bia la impact, alinia\u021bi st\u00e2lpii \u00een amonte \u0219i \u00een aval de terminal conform Access Board ori \u00eenainta\u021bi c\u0103tre AHJ o barier\u0103 aprobat\u0103 conform <strong>IFC &sect;312.3<\/strong> pe baza performan\u021bei (sau conform criteriilor vechi din edi\u021bia 2012 de &ge;36 in \/ 12,000 lb, dac\u0103 mai sunt aplicate local).<\/p>\n\n  <h3>Matricea de conformitate pe patru niveluri (America de Nord &amp; Europa)<\/h3>\n\n  <p class=\"evb-table-title\" id=\"tbl-standards-title\">Patru niveluri de conformitate pentru sta\u021bii de \u00eenc\u0103rcare DC cu trecere direct\u0103<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-standards-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">Nivel de conformitate<\/th>\n          <th scope=\"col\">America de Nord (Statele Unite \/ Canada)<\/th>\n          <th scope=\"col\">Europa \/ interna\u021bional (IEC \/ UE)<\/th>\n          <th scope=\"col\">Verificarea tehnic\u0103 a amplasamentului<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\">1. Lucr\u0103ri civile, accesibilitate &amp; obiective de coridor<\/th>\n          <td><a href=\"https:\/\/www.access-board.gov\/tad\/ev\/#pull-through-ev-charging-stations-design\" rel=\"nofollow\">Orient\u0103rile U.S. Access Board privind \u00eenc\u0103rcarea vehiculelor electrice<\/a>; <a href=\"https:\/\/www.access-board.gov\/ada\/chapter\/ch03\/#308-reach-ranges\" rel=\"nofollow\">ADA &sect;305\/&sect;308<\/a>; <a href=\"https:\/\/mutcd.fhwa.dot.gov\/\" rel=\"nofollow\">FHWA MUTCD<\/a>; reguli statale privind dimensiunile vehiculelor<\/td>\n          <td><a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2023\/1804\/oj\" rel=\"nofollow\">AFIR al UE (Reg. 2023\/1804)<\/a> Art. 4(1)(a\u2013d) &amp; 4(2), grupuri de re\u00eenc\u0103rcare pentru vehicule grele pe fiecare sens: 15% (p\u00e2n\u0103 \u00een 2025) \u0219i 50% (p\u00e2n\u0103 \u00een 2027) din lungimea total\u0103 a drumurilor TEN-T a fiec\u0103rui stat membru (\u00een 2027, tronsoanele acoperite ale re\u021belei <strong>centrale<\/strong> &ge;2.8 MW cu &ge;2 &times; 350 kW; <strong>globale<\/strong> &ge;1.4 MW cu &ge;1 &times; 350 kW); p\u00e2n\u0103 \u00een 2030, acoperire integral\u0103 a re\u021belei <strong>centrale<\/strong> (&le;60 km) &ge;3.6 MW (&ge;2 &times; 350 kW) \u0219i <strong>globale<\/strong> (&le;100 km) &ge;1.5 MW (&ge;1 &times; 350 kW); norme na\u021bionale de accesibilitate<\/td>\n          <td>Verifica\u021bi separat l\u0103\u021bimea locului, pavajul la nivel sau bordurile cobor\u00e2te, cerin\u021bele ADA &sect;305\/&sect;308 privind spa\u021biul liber &amp; accesul, anvelopele de manevr\u0103 \u0219i semnalizarea cu sens unic. L\u0103\u021bimea nu \u00eenlocuie\u0219te accesul la nivel.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">2. Siguran\u021ba ansamblului EVSE &amp; protocoale<\/th>\n          <td>UL 2202 (EVSE DC); certific\u0103ri pentru conectorii NACS \/ CCS1 \/ MCS; op\u021biuni OCPP &amp; ISO 15118<\/td>\n          <td><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/33644\" rel=\"nofollow\">EN IEC 61851-1<\/a> &amp; IEC 61851-23 \/ -24; declara\u021bie UE de conformitate (CE); op\u021biuni ISO 15118-2 \/ -20 &amp; MID\/PTB<\/td>\n          <td>Confirma\u021bi tensiunea exact\u0103 de alimentare AC \u00een regiune (de exemplu, versiune nord-american\u0103 de 480 V AC certificat\u0103 UL fa\u021b\u0103 de 380\u2013415 V AC IEC\/CE) \u0219i verifica\u021bi protocoalele op\u021bionale pentru fiecare cod de produs \u00een cererea de ofert\u0103.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">3. Cablare electric\u0103 &amp; protec\u021bie la impact<\/th>\n          <td><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" rel=\"nofollow\">NFPA 70 (NEC)<\/a> Art. 625 (dimensionare la 125% pentru regim de func\u021bionare continu\u0103, separator &sect;625.43), spa\u021biu de lucru &sect;110.26; IFC &sect;312; Codul electric canadian, partea I<\/td>\n          <td><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">IEC 60364-7-722:2018<\/a>; IEC 60529 (IP) &amp; IEC 62262 (IK), doar pentru protec\u021bia carcaselor \u00eempotriva p\u0103trunderii \u0219i impactului; norme na\u021bionale pentru bariere<\/td>\n          <td>Verifica\u021bi spa\u021biul de lucru \u00een jurul dulapurilor redresoare \u0219i l\u00e2ng\u0103 u\u0219i. Gradele IP\/IK ale carcaselor nu m\u0103soar\u0103 rezisten\u021ba la coroziune \u00een zonele de coast\u0103. Verifica\u021bi separat documenta\u021bia acoperirii de protec\u021bie.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\">4. Clasificarea zonelor periculoase (carburan\u021bi \u0219i \u00eenc\u0103rcare electric\u0103)<\/th>\n          <td>Edi\u021biile adoptate local ale <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-30a-standard-development\/30a\" rel=\"nofollow\">NFPA 30A<\/a>, NEC art. 514 (tabelele de clasificare a zonelor periculoase &amp; separarea electric\u0103 a pompelor de carburant &sect;514.11) \u0219i NEC &sect;625.28<\/td>\n          <td><a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/1999\/92\/oj\/eng\" rel=\"nofollow\">Directiva UE ATEX 1999\/92\/EC privind locurile de munc\u0103<\/a>, Directiva 2014\/34\/EU \u0219i normele na\u021bionale de separare a echipamentelor din sta\u021biile de carburant<\/td>\n          <td>Echipamentele EVSE DC standard sunt proiectate pentru <strong>amplasamente nepericuloase (neclasificate)<\/strong>. Nu exist\u0103 o clauz\u0103 unic\u0103 \u00eentre Statele Unite \u0219i UE. Verifica\u021bi echipamentele \u0219i \u00eentreaga anvelop\u0103 de mi\u0219care a cablului \u00een func\u021bie de carburan\u021bii existen\u021bi (benzin\u0103 sau motorin\u0103), punctele de umplere \u0219i de aerisire, edi\u021bia normei \u00een vigoare \u0219i planul de clasificare aprobat de AHJ.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">Verifica\u021bi \u00eentotdeauna cu autoritatea competent\u0103 (AHJ) edi\u021bia normei adoptate local, planul de clasificare specific carburantului \u0219i condi\u021biile de racordare la re\u021bea.<\/p>\n\n  <h2 id=\"charge-port-placement-cable-reach-and-mcs\">4. Pozi\u021bia prizei, raza cablului &amp; preg\u0103tirea pentru MCS<\/h2>\n\n  <p>Chiar \u0219i o band\u0103 lat\u0103 cu trecere direct\u0103 poate fi inutilizabil\u0103 dac\u0103 un cablu se t\u00e2r\u0103\u0219te pe pavaj sau nu ajunge cu u\u0219urin\u021b\u0103 la priza vehiculului:<\/p>\n\n  <ol>\n    <li><strong>Recomand\u0103rile CharIN pentru priza MCS \u0219i situa\u021bia flotelor mixte:<\/strong> <a href=\"https:\/\/www.charin.global\/media\/pages\/technology\/knowledge-base\/0c2cc2c8da-1747654352\/250508_whitepaper_megawatt_charging_system_2.0.pdf#page=15\" rel=\"nofollow\">Documentul tehnic CharIN despre sistemul de \u00eenc\u0103rcare de ordinul megawa\u021bilor (MCS) 2.0 (pag. 15 \u0219i 17)<\/a> recomand\u0103 amplasarea prizei vehiculului greu pe <strong>partea st\u00e2ng\u0103 a vehiculului<\/strong>, \u00een spatele axei celei mai avansate. Produc\u0103torii consulta\u021bi au indicat pozi\u021bii longitudinale \u00eentre <strong>2.0 m \u0219i 4.8 m<\/strong> de la partea frontal\u0103 a vehiculului. Documentul recomand\u0103 o lungime maxim\u0103 a cablului de <strong>15 m<\/strong>, \u00eens\u0103 raza efectiv\u0103 trebuie verificat\u0103 \u00een func\u021bie de terminal \u0219i traseul cablului. Pick-up-urile \u0219i furgonetele electrice actuale, dar \u0219i camioanele cu prize CCS1\/CCS2 din genera\u021bii precedente, au prize \u00een st\u00e2nga, \u00een dreapta, \u00een fa\u021b\u0103 sau \u00een spate.<\/li>\n    <li><strong>Verificarea pe teren a razei cablului standard de 5 m:<\/strong> Multe terminale DC de mare putere sunt livrate cu un cablu standard de <strong>5 m (16.4 ft)<\/strong> . Din lungime nu se poate stabili dac\u0103 un cablu de 5 m ajunge la un camion sau ansamblu sta\u021bionat, nici folosind reperul U.S. Access Board de 5 ft \u00eentre vehicul \u0219i terminal. Verifica\u021bi <strong>toleran\u021ba de oprire, punctul \u0219i \u00een\u0103l\u021bimea ie\u0219irii cablului, coordonatele exacte ale prizei \u0219i cursa mecanismului de retragere sau a bra\u021bului pivotant<\/strong>. Pentru flotele cu prize pe ambele p\u0103r\u021bi, evalua\u021bi insule cu acces bilateral sau sisteme suspendate de gestionare a cablurilor.<\/li>\n    <li><strong>Preg\u0103tirea tubulaturilor pentru MCS:<\/strong> C\u00e2nd s\u0103pa\u021bi \u0219an\u021buri pe coridoarele de marf\u0103 pentru terminale CCS2\/CCS1 de 350\u2013500 kW, evalua\u021bi tubulaturi de \u00eenalt\u0103 tensiune de rezerv\u0103 \u0219i capacitatea funda\u021biilor, astfel \u00eenc\u00e2t extinderea la <a href=\"https:\/\/www.evb.com\/ro\/mcs-vs-ccs-for-electric-trucks-2026-engineering-roi-grid-reality\/\">sisteme de \u00eenc\u0103rcare de ordinul megawa\u021bilor (MCS \u00een compara\u021bie cu CCS)<\/a> s\u0103 nu impun\u0103 t\u0103ierea platformelor deja finisate.<\/li>\n  <\/ol>\n\n  <h2 id=\"hardware-architecture-and-evb-selection\">5. Alegerea \u00eentre \u00eenc\u0103rc\u0103toare DC separate \u0219i integrate<\/h2>\n\n  <p>Dac\u0103 mai multe locuri folosesc acela\u0219i dulap de putere \u00een afara insulei, compara\u021bi sistemele separate EVB BSDC720 \u0219i BDCS. Dac\u0103 dou\u0103 locuri al\u0103turate cu trecere direct\u0103 pot folosi un \u00eenc\u0103rc\u0103tor de pe insul\u0103, analiza\u021bi EVB BDC240-D. Cei doi conectori \u00eempart o putere total\u0103 de 240 kW. Marca\u021bi pe plan pozi\u021biile ambelor prize \u0219i verifica\u021bi dac\u0103 le ating cablurile cu cele dou\u0103 vehicule sta\u021bionate.<\/p>\n\n  <p class=\"evb-table-title\" id=\"tbl-evb-hardware-title\">Compara\u021bia \u00eenc\u0103rc\u0103toarelor DC EVB pentru amplasamente cu trecere direct\u0103<\/p>\n  <div class=\"evb-table-wrap\" role=\"region\" aria-labelledby=\"tbl-evb-hardware-title\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <thead>\n        <tr>\n          <th scope=\"col\">Model &amp; configura\u021bie<\/th>\n          <th scope=\"col\">Puterea sistemului &amp; a conectorilor<\/th>\n          <th scope=\"col\">Dimensiunile echipamentelor &amp; lungimea cablului<\/th>\n          <th scope=\"col\">Alimentare AC, standarde &amp; protocoale<\/th>\n          <th scope=\"col\">Utilizare pe amplasament &amp; puncte de verificat<\/th>\n        <\/tr>\n      <\/thead>\n      <tbody>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/ro\/product-item\/720kw-liquid-cooling-dc-ev-charging-stations-with-independent-duct\/\">BSDC720-250D5<\/a><br>(sistem DC separat de 720 kW)<\/th>\n          <td>Sistemul furnizeaz\u0103 p\u00e2n\u0103 la <strong>720 kW<\/strong> \u00een total, cu un v\u00e2rf de <strong>500 kW<\/strong> pe terminal. Pentru 500 kW pe un conector sunt necesari aproximativ 1,000 V la vehicul, 500 A la conector \u0219i putere alocat\u0103 suficient\u0103 terminalului. Op\u021biunea <strong>0\u2013500 A cu r\u0103cire cu lichid<\/strong> este disponibil\u0103 cu <strong>CCS2 \/ GB\/T<\/strong> numai. <strong>CCS1 \/ NACS<\/strong> asisten\u021b\u0103 <strong>0\u2013250 A<\/strong> cu cabluri r\u0103cite cu aer (150\u20131,000 V DC). CHAdeMO accept\u0103 0\u2013150 A la 150\u2013500 V DC. Terminalele cu unul sau doi conectori accept\u0103 p\u00e2n\u0103 la 10 conectori \u00een sistem. Verifica\u021bi cum distribuie terminalul ales puterea c\u00e2nd ambii conectori sunt utiliza\u021bi.<\/td>\n          <td>Terminal de \u00eenc\u0103rcare: <strong>600 &times; 230 &times; 1,700 mm<\/strong> (&le;110 kg). Dulap redresor: 1,700 &times; 1,000 &times; 2,150 mm (&le;1,100 kg). Cablu standard: <strong>5 m<\/strong>; IP55, IK10 (ecran IK08).<\/td>\n          <td><strong>380\u2013415 V AC<\/strong>, 3P+N+PE, 50\/60 Hz, curent nominal de intrare de <strong>1,100 A<\/strong>; EN IEC 61851-1\/-23\/-24\/-21-2; OCPP 1.6J.<\/td>\n          <td><strong>Situri comerciale cu mai multe locuri \u0219i popasuri pentru camioane.<\/strong> Pentru un amplasament nord-american, preciza\u021bi tensiunea de alimentare, tensiunea vehiculului \u0219i tipul conectorului. Dac\u0103 ave\u021bi nevoie de 480 V AC \u0219i de certificare UL, \u00eentreba\u021bi dac\u0103 exist\u0103 un model cu documenta\u021bia aferent\u0103. Cere\u021bi EVB s\u0103 confirme curentul CCS1\/NACS, distribuirea puterii \u00eentre conectori \u0219i op\u021biunile pentru cabluri mai lungi sau suspendate.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/ro\/product-item\/floor-mounted-split-dc-megawatt-charging-system\/\">BDCS500\u2013BDCS2000<\/a><br>(sistem modular DC separat de 500 kW\u20132 MW)<\/th>\n          <td><strong>500 \/ 1,000 \/ 1,500 \/ 2,000 kW<\/strong> cu dulapuri redresoare modulare; un singur <strong>MCS<\/strong> conector (0\u20131,250 V DC, <strong>0\u20131,500 A<\/strong> cu r\u0103cire cu lichid) ori doi conectori <strong>CCS2<\/strong> (150\u20131,000 V DC, <strong>0\u2013650 A<\/strong> fiecare, r\u0103ci\u021bi cu lichid).<\/td>\n          <td>Dulapuri redresoare modulare (&le;730 kg pe modul de 500 kW, p\u00e2n\u0103 la &times;4); terminal de \u00eenc\u0103rcare &le;110 kg (verifica\u021bi \u00een documenta\u021bia proiectului planul exact W &times; D &times; H al funda\u021biei). Cablu standard: <strong>5 m<\/strong>; IP55, IK10 (ecran IK08).<\/td>\n          <td><strong>380\u2013415 V AC<\/strong>, 3P+N+PE, 50\/60 Hz (curent nominal de intrare 760\u20133,039 A); randament &ge;97%; EN IEC 61851-1\/-23\/-24\/-21-2; OCPP 1.6J.<\/td>\n          <td><strong>Coridoare TEN-T din UE pentru vehicule grele vizate de AFIR \u0219i centre de \u00eenc\u0103rcare de ordinul megawa\u021bilor pentru camioane.<\/strong> Comunica\u021bi EVB puterea nominal\u0103 a transformatorului, cerin\u021bele vehiculelor \u0219i traseul prev\u0103zut al cablurilor pentru confirmarea configura\u021biei de putere, a op\u021biunilor ISO 15118 \u0219i a razei cablurilor. Pentru un proiect nord-american, verifica\u021bi dac\u0103 este disponibil un model de 480 V cu certificarea UL necesar\u0103.<\/td>\n        <\/tr>\n        <tr>\n          <th scope=\"row\"><a href=\"https:\/\/www.evb.com\/ro\/product-item\/floor-mounted-dc-2-guns-ev-dc-fast-charger\/\">BDC240-D<\/a><br>(\u00eenc\u0103rc\u0103tor DC de pardoseal\u0103 de 240 kW, cu doi conectori)<\/th>\n          <td><strong>240 kW \u00een total<\/strong>, distribui\u021bi dinamic c\u00e2nd se \u00eencarc\u0103 dou\u0103 vehicule. CCS1, CCS2, GB\/T \u0219i NACS accept\u0103 150\u20131,000 V DC \u0219i p\u00e2n\u0103 la 250 A. CHAdeMO accept\u0103 150\u2013500 V DC \u0219i p\u00e2n\u0103 la 150 A. Puterea furnizat\u0103 fiec\u0103rui vehicul depinde de tensiune, de curentul solicitat \u0219i de puterea disponibil\u0103 la conector.<\/td>\n          <td>Dulap: <strong>800 &times; 800 &times; 1,800 mm<\/strong> (&le;440 kg). Lungime cablu standard: <strong>5 m<\/strong>. Carcas\u0103: IP55.<\/td>\n          <td><strong>380\u2013415 V AC<\/strong>, trifazat cu neutru \u0219i conductor de protec\u021bie, 50\/60 Hz. Curent nominal de intrare: <strong>365 A<\/strong>. IEC 61851-1, -23 \u0219i -24. OCPP 1.6J.<\/td>\n          <td><strong>Dou\u0103 locuri al\u0103turate cu trecere direct\u0103 care folosesc acela\u0219i \u00eenc\u0103rc\u0103tor.<\/strong> Rezerva\u021bi spa\u021biu pentru u\u0219ile dulapului \u0219i st\u00e2lpii de protec\u021bie. Pentru un amplasament de 480 V, comunica\u021bi EVB tensiunea de serviciu, certificarea necesar\u0103 \u0219i perechea de conectori, astfel \u00eenc\u00e2t EVB s\u0103 poat\u0103 stabili configura\u021bia potrivit\u0103.<\/td>\n        <\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n  <p class=\"evb-table-note\">Desc\u0103rca\u021bi fi\u0219ele tehnice pentru <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2025\/12\/BENY-Datasheet%EF%BC%88Beny-720kW-Floor-Mounted-Split-DC-EV-Charger-Station%EF%BC%89-2025.12.25.pdf\">BSDC720-250D5 v20251225-01 (PDF)<\/a>, <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/04\/BENY-Datasheetof-Split-Megawatt-Power-DC-EV-Charger-500kW-to-2MW%EF%BC%88BDCS%EF%BC%892026.03.03.pdf\">BDCS500\u20132000 v20260310-01 (PDF)<\/a>\u0219i <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet%EF%BC%88Beny-2-Guns-DC-EV-Charging-Station%EF%BC%892025.12.29.pdf#page=6\">BDC240-D (pagina 6 din PDF)<\/a>. Cele dou\u0103 sisteme separate \u0219i configura\u021bia BDC240-D din tabel sunt destinate amplasamentelor sub 2,000 m \u0219i temperaturilor ambiante \u00eentre &minus;30 \u0219i +50 &deg;C. Confirma\u021bi \u00een oferta proiectului certificarea UL sau documenta\u021bia CE aplicabil\u0103, op\u021biunile ISO 15118, lungimea cablurilor \u0219i planul ancorelor de funda\u021bie.<\/p>\n\n  <h2 id=\"rfq-and-design-verification-checklist\">6. Proiectarea sta\u021biei cu trecere direct\u0103 &amp; lista de verificare pentru cererea de ofert\u0103<\/h2>\n\n  <div class=\"evb-checklist\">\n    <h3>Opt verific\u0103ri \u00eenaintea autoriza\u021biilor de construire &amp; a comenzilor de echipamente<\/h3>\n    <ol>\n      <li><strong>Calculul vehiculului de proiectare &amp; verificarea anvelopei traiectoriei:<\/strong> Documenta\u021bi lungimea exact\u0103 a vehiculului de proiectare \u0219i rezervele din fa\u021b\u0103 \u0219i spate, apoi rula\u021bi AutoTURN sau un program echivalent de la bordura cobor\u00e2t\u0103 p\u00e2n\u0103 la ie\u0219ire pentru a verifica abaterea remorcii, balansul din spate \u0219i distan\u021ba fa\u021b\u0103 de st\u00e2lpii copertinei.<\/li>\n      <li><strong>Num\u0103rul de locuri cu trecere direct\u0103 din modelarea cozilor:<\/strong> Dimensiona\u021bi benzile din sosirile de v\u00e2rf ale camioanelor \u0219i vehiculelor cu remorc\u0103, durata sta\u021bion\u0103rii \u0219i a\u0219teptarea acceptabil\u0103. Prevede\u021bi ie\u0219iri drepte independente, astfel \u00eenc\u00e2t vehiculul din spate care a terminat \u00eenc\u0103rcarea s\u0103 nu r\u0103m\u00e2n\u0103 blocat de cel din fa\u021b\u0103.<\/li>\n      <li><strong>Verific\u0103ri separate de accesibilitate:<\/strong> \u00cen Statele Unite, verifica\u021bi l\u0103\u021bimea locului (&ge;16 ft \/ 4,880 mm), nivelarea sau bordurile cobor\u00e2te, spa\u021biul liber ADA &sect;305, orientarea, ad\u00e2ncimea \u0219i \u00een\u0103l\u021bimea de acces &sect;308 \u0219i posibilitatea racord\u0103rii la un vehicul la 5 ft (1,525 mm). \u00cen afara Statelor Unite, aplica\u021bi normele na\u021bionale.<\/li>\n      <li><strong>Protec\u021bie la impact compatibil\u0103 cu accesul:<\/strong> Confirma\u021bi cu AHJ cerin\u021bele locale IFC &sect;312.2 sau cerin\u021bele pe baz\u0103 de performan\u021b\u0103 &sect;312.3. Alinia\u021bi st\u00e2lpii de protec\u021bie \u00een lateralul terminalului sau utiliza\u021bi bariere aprobate f\u0103r\u0103 a ocupa spa\u021biul pentru scaunele rulante.<\/li>\n      <li><strong>Verificarea zonelor periculoase pentru amplasamentul mixt:<\/strong> Verifica\u021bi carburan\u021bii prezen\u021bi, racordurile de umplere, aerisirile, edi\u021bia normelor \u00een vigoare (NFPA 30A \/ NEC art. 514 \/ ATEX) \u0219i planul de clasificare aprobat de AHJ. Echipamentele EVSE \u0219i \u00eentreaga mi\u0219care a cablului trebuie s\u0103 r\u0103m\u00e2n\u0103 \u00een zonele neclasificate.<\/li>\n      <li><strong>Amplasarea dulapului de putere \u00een afara insulei:<\/strong> Verifica\u021bi degaj\u0103rile de pe platforma dulapului redresor (spa\u021biu de lucru NEC &sect;110.26 \/ IEC), deschiderea u\u0219ilor, protec\u021bia la impact \u0219i fluxul de r\u0103cire \u00een afara benzilor active pentru camioane.<\/li>\n      <li><strong>Validarea razei reale a cablului:<\/strong> Verifica\u021bi dac\u0103 lungimea cablului standard de <strong>5 m<\/strong> ajunge la priz\u0103 \u00een raport cu toleran\u021ba de oprire, \u00een\u0103l\u021bimea ie\u0219irii, coordonatele prizei \u0219i cursa mecanismului de retragere. Dac\u0103 este cazul, specifica\u021bi \u00een cererea de ofert\u0103 un cablu mai lung sau suspendat.<\/li>\n      <li><strong>Puterea amplasamentului \u0219i limitele conectorilor.<\/strong> Corela\u021bi tensiunea \u0219i curentul nominal de intrare AC ale \u00eenc\u0103rc\u0103torului cu alimentarea disponibil\u0103. Pentru BDC240-D, comunica\u021bi EVB perechea de conectori \u0219i puterea necesar\u0103 fiec\u0103rui vehicul cu ambele locuri ocupate. Rezerva\u021bi tubulaturi pentru extindere.<\/li>\n    <\/ol>\n  <\/div>\n\n  <div class=\"evb-callout\">\n    <h3>Proiecta\u021bi o sta\u021bie cu trecere direct\u0103 sau o baz\u0103 pentru camioane electrice?<\/h3>\n    <p>Trimite\u021bi echipei tehnice EVB planul, componen\u021ba flotei \u0219i alimentarea electric\u0103 disponibil\u0103. Echipa poate ajuta la amplasarea terminalelor, verificarea razei cablurilor \u0219i adaptarea curentului conectorilor la vehicule. Include\u021bi cerin\u021bele regionale de aprobare. Consulta\u021bi \u00een portofoliul EVB <a href=\"https:\/\/www.evb.com\/ro\/by-vehicle-type\/electric-truck-charging\/\">solu\u021biile de \u00eenc\u0103rcare pentru camioane electrice<\/a> \u0219i <a href=\"https:\/\/www.evb.com\/ro\/by-industry\/fleet-charging\/\">solu\u021bii de \u00eenc\u0103rcare pentru flote<\/a>sau cere\u021bi o ofert\u0103 pentru proiect.<\/p>\n    <a class=\"evb-cta-btn\" href=\"https:\/\/www.evb.com\/ro\/ev-charger-customization\/\">Solicita\u021bi o ofert\u0103 pentru amplasarea sta\u021biei cu trecere direct\u0103 &amp; echipamente<\/a>\n  <\/div>\n\n  <h2 id=\"frequently-asked-questions\">7. \u00centreb\u0103ri frecvente<\/h2>\n\n  <h3>C\u00e2t de lat trebuie s\u0103 fie un loc de \u00eenc\u0103rcare cu trecere direct\u0103?<\/h3>\n  <p>\u00cen Statele Unite, U.S. Access Board arat\u0103 c\u0103 locurile cu trecere direct\u0103 nu trebuie marcate individual. Recomand\u0103 o l\u0103\u021bime de cel pu\u021bin <strong>16 ft (4,880 mm)<\/strong> \u0219i un cablu care poate ajunge la un vehicul parcat la <strong>5 ft (1,525 mm)<\/strong> de \u00eenc\u0103rc\u0103tor. \u00cen afara Statelor Unite, dimensiona\u021bi l\u0103\u021bimea dup\u0103 standardele na\u021bionale aplicabile vehiculelor grele \u0219i accesibilit\u0103\u021bii.<\/p>\n\n  <h3>Cum se calculeaz\u0103 lungimea unui loc cu trecere direct\u0103 pentru un pick-up cu remorc\u0103 sau un cap tractor cu semiremorc\u0103?<\/h3>\n  <p>Porni\u021bi de la lungimea exact\u0103 a vehiculului de proiectare \u0219i ad\u0103uga\u021bi rezerve de oprire \u00een fa\u021b\u0103 \u0219i \u00een spate. De exemplu, un pick-up cu remorc\u0103 de 50 ft plus 5 ft \u00een fa\u021b\u0103 \u0219i 5 ft \u00een spate necesit\u0103 <strong>60 ft (18.3 m)<\/strong> pentru locul drept; un camion articulat din UE de 16.5 m plus 2.5 m \u00een fa\u021b\u0103 \u0219i \u00een spate necesit\u0103 <strong>21.5 m<\/strong>; un ansamblu din Statele Unite de 73.5 ft plus 10 ft \u00een fa\u021b\u0103 \u0219i \u00een spate necesit\u0103 <strong>93.5 ft (28.5 m)<\/strong>. Verifica\u021bi apoi tangentele de intrare \u0219i ie\u0219ire \u0219i abaterea remorcii prin simularea anvelopei traiectoriei.<\/p>\n\n  <h3>Cum se \u00eempac\u0103 st\u00e2lpii de protec\u021bie la impact cu cerin\u021bele de accesibilitate ale unei insule cu trecere direct\u0103?<\/h3>\n  <p>Verifica\u021bi separat protec\u021bia orizontal\u0103 la impact \u0219i cerin\u021bele capitolului 3 ADA. St\u00e2lpii din o\u021bel umplu\u021bi cu beton, alinia\u021bi \u00een amonte \u0219i \u00een aval de terminal, ori o barier\u0103 conform IFC &sect;312.3 aprobat\u0103 de AHJ protejeaz\u0103 dulapul f\u0103r\u0103 a bloca spa\u021biul liber la nivel &sect;305, direc\u021bia de apropiere sau zonele de acces &sect;308.<\/p>\n\n  <h3>Pot \u00eenc\u0103rc\u0103toarele rapide cu trecere direct\u0103 s\u0103 \u00eempart\u0103 amplasamentul cu pompe de motorin\u0103 sau benzin\u0103?<\/h3>\n  <p>Da, cu condi\u021bia ca EVSE standard pentru locuri nepericuloase s\u0103 fie \u00een zone neclasificate. Separarea depinde de carburant (benzin\u0103 sau motorin\u0103) \u0219i de edi\u021bia codului adoptat local (NFPA 30A \/ NEC art. 514 \u00een SUA, Directiva ATEX 1999\/92\/EC \u0219i norme na\u021bionale \u00een Europa). Compara\u021bi at\u00e2t carcasa echipamentului, c\u00e2t \u0219i \u00eentreaga anvelop\u0103 de mi\u0219care a cablului cu planul de clasificare aprobat de AHJ.<\/p>\n\n  <h3>De ce multe sta\u021bii cu trecere direct\u0103 iau \u00een calcul \u00eenc\u0103rc\u0103toare DC separate \u00een locul dulapurilor integrate?<\/h3>\n  <p>La BSDC720, dulapul redresor de <strong>1,700 &times; 1,000 &times; 2,150 mm<\/strong> poate sta pe o platform\u0103 separat\u0103. Pe insul\u0103 r\u0103m\u00e2ne terminalul compact de <strong>600 &times; 230 &times; 1,700 mm<\/strong> l\u00e2ng\u0103 vehicul. Compara\u021bi pe planuri l\u0103\u021bimea insulei, spa\u021biul de service, protec\u021bia la impact \u0219i costurile pe durata vie\u021bii cu cele ale unei instala\u021bii integrate.<\/p>\n\n  <h3>Un cablu de \u00eenc\u0103rcare de 5 m ajunge la un loc cu trecere direct\u0103?<\/h3>\n  <p>Nu presupune\u021bi c\u0103 5 m (16.4 ft) sunt suficien\u021bi f\u0103r\u0103 s\u0103 modela\u021bi geometria. Verifica\u021bi abaterea de la pozi\u021bia de oprire, \u00een\u0103l\u021bimea ie\u0219irii cablului, pozi\u021bia exact\u0103 a prizei \u0219i cursa de retragere \u00een raport cu distan\u021ba necesar\u0103 \u00eentre vehicul \u0219i terminal (de exemplu 5 ft conform U.S. Access Board). Pentru prize \u00een pozi\u021bii diferite, prevede\u021bi insule bilaterale ori cabluri mai lungi sau suspendate.<\/p>\n\n  <h2 id=\"references\">8. Standarde principale \u0219i referin\u021be tehnice<\/h2>\n  <ul>\n    <li><a href=\"https:\/\/www.access-board.gov\/tad\/ev\/#pull-through-ev-charging-stations-design\" rel=\"nofollow\">U.S. Access Board \u2014 Recomand\u0103ri de proiectare pentru sta\u021biile de \u00eenc\u0103rcare accesibile (sta\u021bii cu trecere direct\u0103)<\/a>: marcaje, l\u0103\u021bime de &ge;16 ft (4,880 mm) a locului \u0219i raz\u0103 de conectare de 5 ft (1,525 mm) (consultat la 24 noiembrie 2026).<\/li>\n    <li><a href=\"https:\/\/www.access-board.gov\/ada\/chapter\/ch03\/#308-reach-ranges\" rel=\"nofollow\">U.S. Access Board \u2014 Capitolul 3 din standardele ADA (&sect;305 Suprafa\u021ba liber\u0103 la sol &amp; &sect;308 Zone de acces)<\/a>: spa\u021biu liber la nivel, direc\u021bie frontal\u0103 ori paralel\u0103 de apropiere, ad\u00e2ncimea obstacolului \u0219i acces la comenzi (consultat la 24 noiembrie 2026).<\/li>\n    <li><a href=\"https:\/\/ops.fhwa.dot.gov\/freight\/publications\/size_regs_final_rpt\/index.htm\" rel=\"nofollow\">Federal Highway Administration din Statele Unite (FHWA) \u2014 Programul privind dimensiunile \u0219i masele vehiculelor comerciale<\/a> &amp; <a href=\"https:\/\/mutcd.fhwa.dot.gov\/\" rel=\"nofollow\">Manualul FHWA privind dispozitivele uniforme de control al traficului (MUTCD)<\/a>: limite federale pentru dimensiunile vehiculelor comerciale \u0219i principii de semnalizare rutier\u0103 (consultat la 24 noiembrie 2026).<\/li>\n    <li><a href=\"https:\/\/driveelectric.gov\/\" rel=\"nofollow\">U.S. Joint Office of Energy and Transportation \u2014 Orient\u0103ri pentru \u00eenc\u0103rcarea public\u0103 &amp; comercial\u0103 a vehiculelor electrice<\/a>: resurse pentru proiectarea amplasamentelor, planificarea coridoarelor \u0219i accesibilitate (consultat la 24 noiembrie 2026).<\/li>\n    <li><a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/1996\/53\/oj\/eng\" rel=\"nofollow\">Uniunea European\u0103 \u2014 Directiva 96\/53\/EC a Consiliului (anexa I)<\/a>: dimensiunile maxime autorizate (lungime articulat\u0103 16.50 m, tren rutier 18.75 m, \u00een\u0103l\u021bime 4.00 m) \u0219i anvelopa de virare (raz\u0103 exterioar\u0103 de 12.50 m \/ interioar\u0103 de 5.30 m; consultat la 24 noiembrie 2026).<\/li>\n    <li><a href=\"https:\/\/eur-lex.europa.eu\/eli\/reg\/2023\/1804\/oj\" rel=\"nofollow\">Uniunea European\u0103 \u2014 Regulamentul (UE) 2023\/1804 (AFIR), articolul 4<\/a>: termene obligatorii pentru amplasarea grupurilor de re\u00eenc\u0103rcare pentru vehicule grele \u00een 2025, 2027 \u0219i 2030 pe re\u021belele TEN-T centrale \u0219i globale (consultat la 24 noiembrie 2026).<\/li>\n    <li><a href=\"https:\/\/eur-lex.europa.eu\/eli\/dir\/1999\/92\/oj\/eng\" rel=\"nofollow\">Uniunea European\u0103 \u2014 Directiva 1999\/92\/EC (Directiva ATEX privind locurile de munc\u0103)<\/a>: cerin\u021be minime pentru clasificarea atmosferelor explozive periculoase \u00een amplasamente mixte (consultat la 24 noiembrie 2026).<\/li>\n    <li><a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-70-standard-development\/70\" rel=\"nofollow\">NFPA 70 (Codul electric na\u021bional \u2014 articolele 110.26, 514 &amp; 625)<\/a> &amp; <a href=\"https:\/\/www.nfpa.org\/codes-and-standards\/nfpa-30a-standard-development\/30a\" rel=\"nofollow\">NFPA 30A (Codul pentru instala\u021biile de distribu\u021bie a carburan\u021bilor \u0219i atelierele de repara\u021bii)<\/a>: circuite de transfer de energie c\u0103tre vehicule electrice, spa\u021bii libere pentru lucr\u0103ri electrice \u0219i clasificarea zonelor cu carburan\u021bi (consultat la 24 noiembrie 2026).<\/li>\n    <li>International Code Council (ICC) \u2014 Codul interna\u021bional de incendiu (IFC), sec\u021biunea 312 (protec\u021bia la impactul vehiculelor): st\u00e2lpi prescri\u0219i \u00een &sect;312.2 \u0219i bariere verificate dup\u0103 performan\u021b\u0103 \u00een &sect;312.3 (verifica\u021bi edi\u021bia local\u0103 cu AHJ).<\/li>\n    <li><a href=\"https:\/\/webstore.iec.ch\/en\/publication\/33644\" rel=\"nofollow\">IEC 61851-1:2017<\/a> (Sistem de \u00eenc\u0103rcare conductiv\u0103 a vehiculelor electrice, partea 1) &amp; <a href=\"https:\/\/webstore.iec.ch\/en\/publication\/29958\" rel=\"nofollow\">IEC 60364-7-722:2018<\/a> (Instala\u021bii electrice de joas\u0103 tensiune \u2014 alimentarea vehiculelor electrice; consultat la 24 noiembrie 2026).<\/li>\n    <li><a href=\"https:\/\/www.charin.global\/media\/pages\/technology\/knowledge-base\/0c2cc2c8da-1747654352\/250508_whitepaper_megawatt_charging_system_2.0.pdf#page=15\" rel=\"nofollow\">CharIN \u2014 Document tehnic pentru sistemul de \u00eenc\u0103rcare de ordinul megawa\u021bilor (MCS) 2.0 (pag. 15 &amp; 17)<\/a>: priza recomandat\u0103 \u00een st\u00e2nga camionului, distan\u021ba de 2.0\u20134.8 m de la partea frontal\u0103 la priz\u0103 raportat\u0103 de produc\u0103tori \u0219i precizarea privind cablul de 15 m (consultat la 24 noiembrie 2026).<\/li>\n    <li>Fi\u0219e tehnice de produs EVB: <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2025\/12\/BENY-Datasheet%EF%BC%88Beny-720kW-Floor-Mounted-Split-DC-EV-Charger-Station%EF%BC%89-2025.12.25.pdf\">BSDC720-250D5, sta\u021bie de \u00eenc\u0103rcare DC separat\u0103 de 720 kW (v20251225-01)<\/a> \u0219i <a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/04\/BENY-Datasheetof-Split-Megawatt-Power-DC-EV-Charger-500kW-to-2MW%EF%BC%88BDCS%EF%BC%892026.03.03.pdf\">BDCS500\u20132000, \u00eenc\u0103rc\u0103tor DC separat de ordinul megawa\u021bilor (v20260310-01)<\/a> (consultat la 24 noiembrie 2026).<\/li>\n    <li><a href=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/01\/BENY-Datasheet%EF%BC%88Beny-2-Guns-DC-EV-Charging-Station%EF%BC%892025.12.29.pdf#page=6\">\u00cenc\u0103rc\u0103tor DC EVB BDC240-D cu doi conectori, fi\u0219a modelului (versiunea 20251229-01, pagina 6 din PDF)<\/a> (consultat la 25 noiembrie 2026).<\/li>\n  <\/ul>\n<\/div>","protected":false},"excerpt":{"rendered":"<p>EVB.COM &middot; Author: EVB Charging Solutions Team &middot; Updated November 2026 &middot; 15-minute read &middot; Pull-Through EV Charging &middot; Commercial DC Fast Charging &middot; Electric Trucks Pull-through EV charging station design lets electric trucks and towing rigs drive straight in and straight out without unhitching or reversing. Size each straight bay from your actual design-vehicle [&hellip;]<\/p>\n","protected":false},"author":3,"featured_media":44856,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[26],"tags":[214,172,487,236],"class_list":["post-44861","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-blog","tag-commercial-ev-charging","tag-electric-truck-charging","tag-pull-through-ev-charging","tag-split-dc-charger"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Pull-Through EV Charging Station Design for Trucks | EVB<\/title>\n<meta name=\"description\" content=\"Plan pull-through EV charging stations for trucks and trailers, check bay dimensions and clearances, and compare split and all-in-one DC fast chargers.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.evb.com\/ro\/pull-through-ev-charging-station-design\/\" \/>\n<meta property=\"og:locale\" content=\"ro_RO\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Pull-Through EV Charging Station Design for Trucks | EVB\" \/>\n<meta property=\"og:description\" content=\"Plan pull-through EV charging stations for trucks and trailers, check bay dimensions and clearances, and compare split and all-in-one DC fast chargers.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.evb.com\/ro\/pull-through-ev-charging-station-design\/\" \/>\n<meta property=\"og:site_name\" content=\"EVB\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-25T05:05:41+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-25T05:05:50+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1600\" \/>\n\t<meta property=\"og:image:height\" content=\"900\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"EVB Editorial Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Scris de\" \/>\n\t<meta name=\"twitter:data1\" content=\"EVB Editorial Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Timp estimat pentru citire\" \/>\n\t<meta name=\"twitter:data2\" content=\"19 minute\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/\"},\"author\":{\"name\":\"EVB Editorial Team\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/person\\\/fe8f0137976034abdfd2ae4f8c5682d0\"},\"headline\":\"Pull-Through EV Charging Station Design: Dimensions, Layout &amp; Split-DC Hardware for Trucks &amp; Towing\",\"datePublished\":\"2026-11-25T05:05:41+00:00\",\"dateModified\":\"2026-11-25T05:05:50+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/\"},\"wordCount\":3924,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/evb-pull-through-ev-charging-station-design-cover.webp\",\"keywords\":[\"commercial EV charging\",\"electric truck charging\",\"Pull-Through EV Charging\",\"split DC charger\"],\"articleSection\":[\"Blog\"],\"inLanguage\":\"ro-RO\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/\",\"url\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/\",\"name\":\"Pull-Through EV Charging Station Design for Trucks | EVB\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/evb-pull-through-ev-charging-station-design-cover.webp\",\"datePublished\":\"2026-11-25T05:05:41+00:00\",\"dateModified\":\"2026-11-25T05:05:50+00:00\",\"description\":\"Plan pull-through EV charging stations for trucks and trailers, check bay dimensions and clearances, and compare split and all-in-one DC fast chargers.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#breadcrumb\"},\"inLanguage\":\"ro-RO\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"ro-RO\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/evb-pull-through-ev-charging-station-design-cover.webp\",\"contentUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/evb-pull-through-ev-charging-station-design-cover.webp\",\"width\":1600,\"height\":900,\"caption\":\"evb pull through ev charging station design cover\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/pull-through-ev-charging-station-design\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.evb.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Pull-Through EV Charging Station Design: Dimensions, Layout &amp; Split-DC Hardware for Trucks &amp; Towing\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#website\",\"url\":\"https:\\\/\\\/www.evb.com\\\/\",\"name\":\"EVB\",\"description\":\"Smart EV Charging &amp; Energy Storage Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.evb.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"ro-RO\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\",\"name\":\"EVB\",\"url\":\"https:\\\/\\\/www.evb.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ro-RO\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/evb-3.png\",\"contentUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/evb-3.png\",\"width\":605,\"height\":626,\"caption\":\"EVB\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/person\\\/fe8f0137976034abdfd2ae4f8c5682d0\",\"name\":\"EVB Editorial Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"ro-RO\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"caption\":\"EVB Editorial Team\"},\"description\":\"The EVB Editorial Team creates expert content on EV charging infrastructure, commercial charging solutions, energy storage integration, and global charging projects, with input from EVB product and engineering specialists.\",\"sameAs\":[\"https:\\\/\\\/www.evb.com\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Proiectarea sta\u021biilor de \u00eenc\u0103rcare cu trecere direct\u0103 pentru camioane | EVB","description":"Proiecta\u021bi sta\u021bii de \u00eenc\u0103rcare cu trecere direct\u0103 pentru camioane \u0219i remorci, verifica\u021bi dimensiunile \u0219i degaj\u0103rile \u0219i compara\u021bi \u00eenc\u0103rc\u0103toarele rapide DC cu arhitectur\u0103 separat\u0103 \u0219i cele integrate.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.evb.com\/ro\/pull-through-ev-charging-station-design\/","og_locale":"ro_RO","og_type":"article","og_title":"Pull-Through EV Charging Station Design for Trucks | EVB","og_description":"Plan pull-through EV charging stations for trucks and trailers, check bay dimensions and clearances, and compare split and all-in-one DC fast chargers.","og_url":"https:\/\/www.evb.com\/ro\/pull-through-ev-charging-station-design\/","og_site_name":"EVB","article_published_time":"2026-11-25T05:05:41+00:00","article_modified_time":"2026-11-25T05:05:50+00:00","og_image":[{"width":1600,"height":900,"url":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp","type":"image\/webp"}],"author":"EVB Editorial Team","twitter_card":"summary_large_image","twitter_misc":{"Scris de":"EVB Editorial Team","Timp estimat pentru citire":"19 minute"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#article","isPartOf":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/"},"author":{"name":"EVB Editorial Team","@id":"https:\/\/www.evb.com\/#\/schema\/person\/fe8f0137976034abdfd2ae4f8c5682d0"},"headline":"Pull-Through EV Charging Station Design: Dimensions, Layout &amp; Split-DC Hardware for Trucks &amp; Towing","datePublished":"2026-11-25T05:05:41+00:00","dateModified":"2026-11-25T05:05:50+00:00","mainEntityOfPage":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/"},"wordCount":3924,"commentCount":0,"publisher":{"@id":"https:\/\/www.evb.com\/#organization"},"image":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#primaryimage"},"thumbnailUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp","keywords":["commercial EV charging","electric truck charging","Pull-Through EV Charging","split DC charger"],"articleSection":["Blog"],"inLanguage":"ro-RO","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/","url":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/","name":"Proiectarea sta\u021biilor de \u00eenc\u0103rcare cu trecere direct\u0103 pentru camioane | EVB","isPartOf":{"@id":"https:\/\/www.evb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#primaryimage"},"image":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#primaryimage"},"thumbnailUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp","datePublished":"2026-11-25T05:05:41+00:00","dateModified":"2026-11-25T05:05:50+00:00","description":"Proiecta\u021bi sta\u021bii de \u00eenc\u0103rcare cu trecere direct\u0103 pentru camioane \u0219i remorci, verifica\u021bi dimensiunile \u0219i degaj\u0103rile \u0219i compara\u021bi \u00eenc\u0103rc\u0103toarele rapide DC cu arhitectur\u0103 separat\u0103 \u0219i cele integrate.","breadcrumb":{"@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#breadcrumb"},"inLanguage":"ro-RO","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/"]}]},{"@type":"ImageObject","inLanguage":"ro-RO","@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#primaryimage","url":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp","contentUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/evb-pull-through-ev-charging-station-design-cover.webp","width":1600,"height":900,"caption":"evb pull through ev charging station design cover"},{"@type":"BreadcrumbList","@id":"https:\/\/www.evb.com\/pull-through-ev-charging-station-design\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.evb.com\/"},{"@type":"ListItem","position":2,"name":"Pull-Through EV Charging Station Design: Dimensions, Layout &amp; Split-DC Hardware for Trucks &amp; Towing"}]},{"@type":"WebSite","@id":"https:\/\/www.evb.com\/#website","url":"https:\/\/www.evb.com\/","name":"EVB","description":"Solu\u021bii inteligente de \u00eenc\u0103rcare EV \u0219i stocare a energiei","publisher":{"@id":"https:\/\/www.evb.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.evb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"ro-RO"},{"@type":"Organization","@id":"https:\/\/www.evb.com\/#organization","name":"EVB","url":"https:\/\/www.evb.com\/","logo":{"@type":"ImageObject","inLanguage":"ro-RO","@id":"https:\/\/www.evb.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.evb.com\/wp-content\/uploads\/2021\/03\/evb-3.png","contentUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2021\/03\/evb-3.png","width":605,"height":626,"caption":"EVB"},"image":{"@id":"https:\/\/www.evb.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.evb.com\/#\/schema\/person\/fe8f0137976034abdfd2ae4f8c5682d0","name":"Echipa editorial\u0103 EVB","image":{"@type":"ImageObject","inLanguage":"ro-RO","@id":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","caption":"EVB Editorial Team"},"description":"Echipa editorial\u0103 EVB creeaz\u0103 con\u021binut de specialitate despre infrastructura de \u00eenc\u0103rcare a vehiculelor electrice, solu\u021bii de \u00eenc\u0103rcare comercial\u0103, integrarea stoc\u0103rii energiei \u0219i proiecte de \u00eenc\u0103rcare la nivel global, cu contribu\u021bii din partea speciali\u0219tilor EVB \u00een produse \u0219i inginerie.","sameAs":["https:\/\/www.evb.com\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.evb.com\/ro\/wp-json\/wp\/v2\/posts\/44861","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.evb.com\/ro\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.evb.com\/ro\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.evb.com\/ro\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.evb.com\/ro\/wp-json\/wp\/v2\/comments?post=44861"}],"version-history":[{"count":1,"href":"https:\/\/www.evb.com\/ro\/wp-json\/wp\/v2\/posts\/44861\/revisions"}],"predecessor-version":[{"id":44869,"href":"https:\/\/www.evb.com\/ro\/wp-json\/wp\/v2\/posts\/44861\/revisions\/44869"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.evb.com\/ro\/wp-json\/wp\/v2\/media\/44856"}],"wp:attachment":[{"href":"https:\/\/www.evb.com\/ro\/wp-json\/wp\/v2\/media?parent=44861"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.evb.com\/ro\/wp-json\/wp\/v2\/categories?post=44861"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.evb.com\/ro\/wp-json\/wp\/v2\/tags?post=44861"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}