{"id":44790,"date":"2026-11-17T14:23:07","date_gmt":"2026-11-17T06:23:07","guid":{"rendered":"https:\/\/www.evb.com\/?p=44790"},"modified":"2026-11-17T16:08:59","modified_gmt":"2026-11-17T08:08:59","slug":"ada-ev-charging-requirements","status":"publish","type":"post","link":"https:\/\/www.evb.com\/tr\/ada-ev-charging-requirements\/","title":{"rendered":"ABD Ticari Alanlar\u0131 i\u00e7in ADA Elektrikli Ara\u00e7 \u015earj Gereksinimleri"},"content":{"rendered":"<style>\n.evb-ada-article{font-family:inherit;color:#1f1f1f;font-size:17px;line-height:1.8;overflow-wrap:break-word}\n.evb-ada-article h2,.evb-ada-article h3{color:#0b2239;line-height:1.3}\n.evb-ada-article h2{font-size:30px;font-weight:800;margin:46px 0 14px}\n.evb-ada-article h3{font-size:22px;font-weight:700;margin:26px 0 10px}\n.evb-ada-article p{margin:0 0 18px;color:#444}\n.evb-ada-article a{color:#185fa5;text-decoration:underline;text-underline-offset:2px}\n.evb-ada-article a:focus-visible,.evb-ada-article .evb-table-wrap:focus-visible{outline:2px solid #185fa5;outline-offset:3px}\n.evb-ada-article .evb-eeat-line{margin:0 0 28px;color:#727e8a;font-size:15px;line-height:1.7}\n.evb-ada-article .evb-article-intro{border-left:3px solid #378add;padding-left:18px;margin:0 0 24px;font-size:18px;line-height:1.75}\n.evb-ada-article ul,.evb-ada-article ol{margin:0 0 18px 22px;padding:0}\n.evb-ada-article li{margin:0 0 8px}\n.evb-ada-article .evb-table-wrap{max-width:100%;overflow-x:auto;margin:18px 0 26px}\n.evb-ada-article .evb-table{width:100%;min-width:560px;border-collapse:collapse;font-size:15px}\n.evb-ada-article .evb-table caption{text-align:left;color:#0b2239;font-weight:700;padding:0 0 8px}\n.evb-ada-article .evb-table th,.evb-ada-article .evb-table td{border:1px solid #e0e5ea;padding:12px 14px;text-align:left;vertical-align:top}\n.evb-ada-article .evb-table thead th{background:#f2f5f8;color:#36485b;font-size:13px;letter-spacing:.02em}\n.evb-ada-article .evb-table tbody th{color:#0b2239;font-weight:700}\n.evb-ada-article .evb-callout{background:#0b2239;color:#fff;border-radius:8px;padding:22px 24px;margin:32px 0}\n.evb-ada-article .evb-callout h3,.evb-ada-article .evb-callout p{color:#f1f6fb}\n.evb-ada-article .evb-callout h3{margin-top:0}\n.evb-ada-article .evb-callout>:last-child{margin-bottom:0}\n.evb-ada-article .evb-callout a{color:#a7d7ff}\n.evb-ada-article .evb-article-figure{margin:24px 0 28px}\n.evb-ada-article .evb-article-figure img{display:block;width:100%;height:auto;border-radius:8px;border:1px solid #dce5ef}\n.evb-ada-article figcaption{margin-top:8px;color:#526171;font-size:.88em;line-height:1.5}\n.evb-ada-article .evb-bay-grid{display:grid;grid-template-columns:1.25fr 0.75fr 1.25fr;gap:0;border:2px solid #9ab0c4;border-radius:8px;background:#f7f9fc;overflow:hidden;font-size:13px;line-height:1.45}\n.evb-ada-article .evb-bay-col{padding:12px;border-right:2px dashed #9ab0c4;display:flex;flex-direction:column;justify-content:space-between;min-height:190px}\n.evb-ada-article .evb-bay-col:last-child{border-right:0}\n.evb-ada-article .evb-bay-aisle{background:#e7f0f8;text-align:center}\n.evb-ada-article .evb-bay-head{font-weight:700;color:#0b2239;margin:0 0 6px}\n.evb-ada-article .evb-bay-pad{border:1px solid #185fa5;background:#fff;border-radius:6px;padding:8px;margin-bottom:8px;color:#1c3d5a}\n.evb-ada-article .evb-bay-cfs{border:1px dashed #185fa5;background:#eef5fc;border-radius:4px;padding:5px 7px;margin-top:6px;font-size:12px;color:#14497a}\n.evb-ada-article .evb-bay-note{margin:0;color:#445668;font-size:12px}\n.evb-ada-article .evb-sources{font-size:15px;color:#526171}\n@media(max-width:768px){.evb-ada-article{font-size:16px}.evb-ada-article h2{font-size:24px}.evb-ada-article h3{font-size:20px}.evb-ada-article .evb-table{font-size:14px}}\n@media(max-width:560px){.evb-ada-article .evb-bay-grid{grid-template-columns:1fr}.evb-ada-article .evb-bay-col{border-right:0;border-bottom:2px dashed #9ab0c4;min-height:auto}.evb-ada-article .evb-bay-col:last-child{border-bottom:0}}\n<\/style>\n<article class=\"evb-ada-article\" lang=\"en-US\">\n  <div class=\"evb-eeat-line\">EVB.COM \u00b7 Yazar: EVB \u015earj \u00c7\u00f6z\u00fcmleri Ekibi \u00b7 G\u00fcncelleme: Kas\u0131m 2026 \u00b7 14 dakikal\u0131k okuma s\u00fcresi \u00b7 Ticari Elektrikli Ara\u00e7 \u015earj\u0131 \u00b7 DC H\u0131zl\u0131 \u015earj \u00b7 Site Eri\u015filebilirli\u011fi<\/div>\n\n  <p class=\"evb-article-intro\"><strong>ABD&#039;deki ticari elektrikli ara\u00e7 \u015farj istasyonlar\u0131, projenin uygulanmas\u0131na ili\u015fkin eyalet, yerel veya kamu finansman\u0131 kurallar\u0131n\u0131n yan\u0131 s\u0131ra, 2010 ADA Eri\u015filebilir Tasar\u0131m Standartlar\u0131na da uymal\u0131d\u0131r.<\/strong> ABD Eri\u015fim Kurulu&#039;nun Eyl\u00fcl 2024 tarihli elektrikli ara\u00e7 \u015farj istasyonlar\u0131na ili\u015fkin \u00f6nerilen kural\u0131 \u015fu anda aktif de\u011fil olarak listeleniyor, bu nedenle proje ekipleri yaln\u0131zca 2024 kural \u00f6zetlerine g\u00f6re tasar\u0131m yapmamal\u0131d\u0131r. Bunun yerine, g\u00fczergahlar, bo\u015f zemin alan\u0131, eri\u015fim mesafeleri ve \u00e7al\u0131\u015ft\u0131r\u0131labilir par\u00e7alar i\u00e7in uygulanabilir ADA teknik kurallar\u0131n\u0131 temel alarak, bunlar\u0131 Eri\u015fim Kurulu&#039;nun elektrikli ara\u00e7 tasar\u0131m \u00f6nerileriyle birle\u015ftirin ve beton d\u00f6kmeden \u00f6nce eyalet kodunun kapsam\u0131n\u0131 do\u011frulay\u0131n.<\/p>\n\n  <p>Eri\u015filebilir elektrikli ara\u00e7 \u015farj istasyonlar\u0131, genellikle in\u015faat tasar\u0131mc\u0131lar\u0131, elektrik\u00e7iler ve \u015farj cihaz\u0131 tedarik\u00e7ileri ayr\u0131 ayr\u0131 \u00e7al\u0131\u015ft\u0131\u011f\u0131nda ba\u015far\u0131s\u0131z olur. Bir \u015farj istasyonu, saha plan\u0131nda yeterince geni\u015f \u015feritlerle g\u00f6sterilse bile, bir kaide eri\u015fim koridoruna d\u00fc\u015ft\u00fc\u011f\u00fcnde, bir kald\u0131r\u0131m tekerlekli sandalye yakla\u015f\u0131m\u0131n\u0131 engelledi\u011finde veya bir kredi kart\u0131 okuyucusu 48 in\u00e7lik eri\u015fim s\u0131n\u0131r\u0131n\u0131n \u00fczerinde kald\u0131\u011f\u0131nda kullan\u0131lamaz hale gelebilir. \u015earj istasyonu geometrisi, donan\u0131m boyutlar\u0131 ve kablo y\u00f6nlendirmesinin erken a\u015famada koordine edilmesi, izin incelemesi ve teslimat s\u0131ras\u0131nda maliyetli saha \u00e7al\u0131\u015fmalar\u0131n\u0131 \u00f6nler.<\/p>\n\n  <h2 id=\"active-rules-vs-guidance\">1. Aktif Kurallar\u0131, Federal Rehberleri ve Eyalet Kanunlar\u0131n\u0131 Ayr\u0131 Ayr\u0131 Ele Almak<\/h2>\n  <p>Amerikan Engelliler Yasas\u0131&#039;n\u0131n (ADA) II. Ba\u015fl\u0131\u011f\u0131 (devlet ve yerel y\u00f6netim tesisleri) ve III. Ba\u015fl\u0131\u011f\u0131 (kamuya a\u00e7\u0131k konaklama yerleri ve ticari tesisler) uyar\u0131nca, 2010 ADA Standartlar\u0131 ba\u011f\u0131ms\u0131z bir EV \u015farj kapsam tablosu i\u00e7ermese bile, kapsama giren EV \u015farj noktalar\u0131n\u0131n eri\u015filebilir olmas\u0131 gerekmektedir. Elemanlara \u00f6zg\u00fc bir kapsam tablosu bulunmad\u0131\u011f\u0131 durumlarda, Adalet Bakanl\u0131\u011f\u0131 (DOJ) d\u00fczenlemeleri, zemin y\u00fczeyleri, a\u00e7\u0131k zemin alan\u0131, eri\u015fim mesafeleri, \u00e7al\u0131\u015ft\u0131r\u0131labilir par\u00e7alar ve eri\u015filebilir g\u00fczergahlar i\u00e7in ge\u00e7erli teknik b\u00f6l\u00fcmlere uyan &quot;makul say\u0131da&quot; eri\u015filebilir eleman gerektirmektedir. Federal kurumlar ve federal olarak finanse edilen tesisler ayr\u0131ca Mimari Engeller Yasas\u0131 (ABA) ve Revize Edilmi\u015f B\u00f6l\u00fcm 508 bilgi ve ileti\u015fim teknolojisi kurallar\u0131na da tabidir.<\/p>\n\n  <p>Bir\u00e7ok eski k\u0131lavuz, ABD Eri\u015fim Kurulu&#039;nun 3 Eyl\u00fcl 2024 tarihli \u00d6nerilen Kural Koyma Bildirimi&#039;nin (eri\u015filebilir elektrikli ara\u00e7 park yeri oran\u0131n\u0131n 1\/25 olmas\u0131n\u0131 ve kamuya a\u00e7\u0131k alanlar i\u00e7in zorunlu B\u00f6l\u00fcm 508 ileti\u015fim \u00f6zelliklerini \u00f6neren) otomatik olarak ba\u011flay\u0131c\u0131 yasa haline geldi\u011fini varsaymaktad\u0131r. Eri\u015fim Kurulu, 2027 Mali Y\u0131l\u0131 Kurum Performans Plan\u0131&#039;nda, elektrikli ara\u00e7 \u015farj istasyonlar\u0131na ili\u015fkin kural koyma s\u00fcrecinin hangi a\u015famaya getirildi\u011fini a\u00e7\u0131k\u00e7a belirtmektedir. <strong>pasif durum<\/strong>Sitenizde hangi kurallar\u0131n ge\u00e7erli oldu\u011funu d\u00f6rt katman\u0131 birlikte kontrol ederek do\u011frulay\u0131n.<\/p>\n\n  <div class=\"evb-table-wrap\" role=\"region\" aria-label=\"ABD&#039;deki elektrikli ara\u00e7 \u015farj eri\u015filebilirli\u011fi kurallar\u0131 ve k\u0131lavuzlar\u0131n\u0131n kar\u015f\u0131la\u015ft\u0131r\u0131lmas\u0131\" tabindex=\"0\">\n    <table class=\"evb-table\">\n      <caption>ABD eri\u015filebilirlik \u00e7er\u00e7evelerinin ticari elektrikli ara\u00e7 \u015farj projelerine nas\u0131l uyguland\u0131\u011f\u0131<\/caption>\n      <thead><tr><th scope=\"col\">\u00c7er\u00e7eve<\/th><th scope=\"col\">Durum (Kas\u0131m 2026&#039;da kontrol edildi)<\/th><th scope=\"col\">Neyi y\u00f6netir?<\/th><th scope=\"col\">Proje ekiplerinin do\u011frulamas\u0131 gerekenler<\/th><\/tr><\/thead>\n      <tbody>\n        <tr><th scope=\"row\">2010 ADA Eri\u015filebilir Tasar\u0131m Standartlar\u0131<\/th><td>Aktif, uygulanabilir federal temel<\/td><td>Eri\u015filebilir g\u00fczergahlar (\u00a7402\/\u00a7403), zemin y\u00fczeyleri (\u00a7302), 30 \u00d7 48 in\u00e7 net zemin alan\u0131 (\u00a7305), eri\u015fim aral\u0131klar\u0131 (\u00a7308), \u00e7al\u0131\u015ft\u0131r\u0131labilir par\u00e7alar \u2264 5 lbf (\u00a7309) ve de\u011fi\u015fiklikler (\u00a7202.3).<\/td><td>T\u00fcm eri\u015filebilir \u015farj cihazlar\u0131n\u0131n teknik \u015fartlar\u0131 kar\u015f\u0131lad\u0131\u011f\u0131ndan ve mevcut eri\u015filebilir park yeri say\u0131s\u0131n\u0131 azaltmad\u0131\u011f\u0131ndan emin olun.<\/td><\/tr>\n        <tr><th scope=\"row\">ABD Eri\u015fim Kurulu Elektrikli Ara\u00e7 Tasar\u0131m \u00d6nerileri<\/th><td>Aktif teknik destek (ba\u011flay\u0131c\u0131 olmayan)<\/td><td>11 x 20 ft \u00f6l\u00e7\u00fclerinde tuvalet kabinleri, 5 ft geni\u015fli\u011finde eri\u015fim koridorlar\u0131, ayn\u0131 seviyede \u015farj pedleri, en az iki adet engelli eri\u015fimine uygun alan ve &quot;son kullan\u0131n&quot; tabelas\u0131 \u00f6nerilir.<\/td><td>Yerel y\u00f6netmeli\u011fin yetersiz kald\u0131\u011f\u0131 durumlarda yerle\u015fim plan\u0131 \u00f6l\u00e7\u00fct\u00fc olarak kullan\u0131n; say\u0131m ve i\u015faretleme konusunda yerel yetkililerin beklentilerini do\u011frulay\u0131n.<\/td><\/tr>\n        <tr><th scope=\"row\">Eri\u015fim Kurulu Eyl\u00fcl 2024 EVSE NPRM<\/th><td>Pasif kural koyma<\/td><td>\u015earj cihaz\u0131 t\u00fcr\u00fcne g\u00f6re 1\/25 oran\u0131nda kapsam belirleme ve geni\u015f kapsaml\u0131 ileti\u015fim talimatlar\u0131 \u00f6nerilmi\u015fti.<\/td><td>\u00d6nerilen kural metnini ba\u011flay\u0131c\u0131 federal yasa olarak g\u00f6rmeyin; bunun yerine eyalet\/yerel d\u00fczeydeki benimsemeleri takip edin.<\/td><\/tr>\n        <tr><th scope=\"row\">23 CFR B\u00f6l\u00fcm 680 (NEVI ve kapsanan federal projeler)<\/th><td>Kapsam dahilindeki federal fonlu projeler i\u00e7in aktiftir.<\/td><td>Temass\u0131z \u00f6deme + telefon\/SMS eri\u015fimi (\u00a7680.106(f)), ADA uyumlu \u00e7ok dilli sorun bildirimi (\u00a7680.106(k)) ve \u00e7ekme\/ta\u015f\u0131ma API alanlar\u0131 (\u00a7680.116(c)).<\/td><td>Sat\u0131n alma i\u015fleminden \u00f6nce \u00a7680.102 uyar\u0131nca fonlaman\u0131n uygulanabilirli\u011fini do\u011frulay\u0131n ve \u00f6deme, raporlama ve API veri \u00f6zelliklerini teyit edin.<\/td><\/tr>\n        <tr><th scope=\"row\">Eyalet ve yerel bina y\u00f6netmelikleri (\u00f6rne\u011fin, CA CBC B\u00f6l\u00fcm 11B)<\/th><td>Kabul edildi\u011fi yerde uygulanabilir<\/td><td>Zorunlu park yeri say\u0131lar\u0131, minib\u00fcs\/standart\/engelli ara\u00e7 kar\u0131\u015f\u0131m\u0131, ek park kurallar\u0131 ve \u015ferit i\u015faretleme\/levha detaylar\u0131.<\/td><td>Kaliforniya Tablosu 11B-228.3.2.1&#039;i (1-4 EVCS i\u00e7in 1 minib\u00fcs alan\u0131; 5-25 i\u00e7in 1 minib\u00fcs + 1 standart alan) veya ilgili yerel IBC\/eyalet de\u011fi\u015fikliklerini kontrol edin.<\/td><\/tr>\n      <\/tbody>\n    <\/table>\n  <\/div>\n\n  <p>\u00c7al\u0131\u015fanlara \u00f6zel ara\u00e7 \u015farj istasyonlar\u0131nda dikkatlice incelenmesi gereken dar bir istisna bulunmaktad\u0131r. 2010 ADA Standartlar\u0131 \u00a7203.9 uyar\u0131nca, ticari bir tesiste yaln\u0131zca \u00e7al\u0131\u015fanlar\u0131n \u015firket veya filo ara\u00e7lar\u0131n\u0131 \u015farj etmesi i\u00e7in kurulan \u015farj cihazlar\u0131, \u00e7al\u0131\u015fan \u00e7al\u0131\u015fma alan\u0131 istisnas\u0131 kapsam\u0131nda de\u011ferlendirilebilir; ancak Eri\u015fim Kurulu, makul bir d\u00fczenleme i\u00e7in en az bir adet hareket kabiliyetine uygun \u015farj cihaz\u0131n\u0131n bulunmas\u0131n\u0131 yine de \u00f6nermektedir. \u00c7al\u0131\u015fanlar ki\u015fisel ara\u00e7lar\u0131n\u0131 orada \u015farj edebiliyorsa veya harici ticari filolar depoyu kullan\u0131yorsa, bu istisna ge\u00e7erli de\u011fildir.<\/p>\n\n  <h2 id=\"stall-dimensions-and-routes\">2. Tezgah Boyutlar\u0131n\u0131, Eri\u015fim Koridorlar\u0131n\u0131 ve Saha G\u00fczergahlar\u0131n\u0131 Planlay\u0131n<\/h2>\n  <p>Engelli eri\u015fimine uygun bir elektrikli ara\u00e7 \u015farj alan\u0131 tasarlamak, standart bir engelli park yerini i\u015faretlemekten farkl\u0131d\u0131r \u00e7\u00fcnk\u00fc elektrikli ara\u00e7 \u015farj giri\u015fleri ara\u00e7 modeline ba\u011fl\u0131 olarak \u00f6n, arka, s\u00fcr\u00fcc\u00fc veya yolcu taraf\u0131nda bulunur. Tekerlekli sandalye veya y\u00fcr\u00fcte\u00e7 kullanan bir s\u00fcr\u00fcc\u00fcn\u00fcn eri\u015fim koridoruna \u00e7\u0131kmas\u0131, \u015farj cihaz\u0131 aray\u00fcz\u00fcne ula\u015fmas\u0131 ve konekt\u00f6r\u00fc arac\u0131n \u015farj portuna ta\u015f\u0131mas\u0131 i\u00e7in yeterli alana ihtiyac\u0131 vard\u0131r.<\/p>\n\n  <h3 id=\"stall-and-aisle-geometry\">Tuvalet kabinini ve ortak kullan\u0131m koridorunu birlikte boyutland\u0131r\u0131n.<\/h3>\n  <p>ABD Eri\u015fim Kurulu, en az\u0131ndan bir ara\u00e7 \u015farj alan\u0131 bulunmas\u0131n\u0131 \u00f6nermektedir. <strong>132 in\u00e7 (11 fit) geni\u015fli\u011finde ve 240 in\u00e7 (20 fit) uzunlu\u011funda.<\/strong> biti\u015fik bir ile e\u015fle\u015ftirildi <strong>60 in\u00e7 (5 fit) geni\u015fli\u011finde eri\u015fim koridoru<\/strong> Alan\u0131n t\u00fcm uzunlu\u011fu boyunca uzanan bir \u015ferit. \u0130ki eri\u015filebilir \u015farj alan\u0131, 60 in\u00e7lik merkezi bir eri\u015fim koridorunu payla\u015fabilir. \u0130ki 8 fitlik park yerini 8 fitlik bir koridorla e\u015fle\u015ftiren standart park istisnas\u0131 (\u00a7502.2) uygulanmas\u0131ndan ka\u00e7\u0131n\u0131n, \u00e7\u00fcnk\u00fc 8 fitlik bir park yeri, yolcu taraf\u0131ndaki veya arka \u015farj giri\u015fine ula\u015fmak i\u00e7in bir araban\u0131n etraf\u0131nda manevra yapmak i\u00e7in uzak tarafta \u00e7ok az yer b\u0131rak\u0131r.<\/p>\n\n  <p>Hem ara\u00e7 \u015farj alan\u0131 hem de eri\u015fim koridoru, d\u00fcz, sa\u011flam, kaymaz ve e\u011fimleri d\u00fczg\u00fcn bir y\u00fczeye sahip olmal\u0131d\u0131r. <strong>1:48&#039;den (yakla\u015f\u0131k 2%) daha dik de\u011fil<\/strong> Herhangi bir y\u00f6nde. \u0130stasyonlar bir otopark\u0131n i\u00e7inde yer al\u0131yorsa, en az\u0131ndan \u015funu koruyun: <strong>98 in\u00e7 dikey a\u00e7\u0131kl\u0131k<\/strong> Ara\u00e7 trafi\u011fine a\u00e7\u0131k g\u00fczergah boyunca eri\u015filebilir alana ve koridora kadar uzanan ve \u015farj b\u00f6lgesini binan\u0131n veya alan\u0131n eri\u015filebilir yaya giri\u015fine en k\u0131sa pratik eri\u015filebilir g\u00fczergah \u00fczerinden (\u00a7403.5 uyar\u0131nca minimum 36 in\u00e7 net geni\u015flik) ba\u011flayan bir yol olu\u015fturun.<\/p>\n\n  <figure class=\"evb-article-figure\" id=\"accessible-bay-layout-diagram\">\n    <div class=\"evb-bay-grid\" aria-hidden=\"true\">\n      <div class=\"evb-bay-col\">\n        <div class=\"evb-bay-pad\"><strong>\u015earj Cihaz\u0131 \/ Da\u011f\u0131t\u0131c\u0131 B\u00f6lgesi<\/strong><br>Ayn\u0131 seviyede zemin (e\u011fim \u2264 1:48). A\u00e7\u0131k alan\u0131n d\u0131\u015f\u0131nda bariyerler.<\/div>\n        <p class=\"evb-bay-head\">Eri\u015filebilir Elektrikli Ara\u00e7 Dura\u011f\u0131 A<\/p>\n        <p class=\"evb-bay-note\">En az 11 ft (132 in) \u00d7 20 ft (240 in). De\u011fi\u015fken giri\u015f taraflar\u0131 i\u00e7in arac\u0131n d\u00f6nebilece\u011fi alan.<\/p>\n      <\/div>\n      <div class=\"evb-bay-col evb-bay-aisle\">\n        <div class=\"evb-bay-cfs\"><strong>Bo\u015f Zemin Alan\u0131<\/strong><br>En az 30 \u00d7 48 in\u00e7<br>\u00c7al\u0131\u015ft\u0131r\u0131labilir par\u00e7alara paralel<\/div>\n        <p class=\"evb-bay-head\">Ortak Eri\u015fim Koridoru<\/p>\n        <p class=\"evb-bay-note\">En az 5 ft (60 in\u00e7) geni\u015fli\u011finde, tam uzunlukta olmal\u0131d\u0131r. Koridor i\u00e7inde bord\u00fcr, bariyer veya kablo sarkmas\u0131 olmamal\u0131d\u0131r.<\/p>\n      <\/div>\n      <div class=\"evb-bay-col\">\n        <div class=\"evb-bay-pad\"><strong>Eri\u015filebilir G\u00fczergah (\u2265 36 in\u00e7)<\/strong><br>Kald\u0131r\u0131ma\/tesis giri\u015fine do\u011frudan ba\u011flant\u0131.<\/div>\n        <p class=\"evb-bay-head\">Eri\u015filebilir Elektrikli Ara\u00e7 Park Yeri B<\/p>\n        <p class=\"evb-bay-note\">En az 11 ft (132 in) \u00d7 20 ft (240 in). 5 ft&#039;lik koridorun payla\u015f\u0131lmas\u0131, farkl\u0131 liman y\u00f6nelimlerine olanak sa\u011flar.<\/p>\n      <\/div>\n    <\/div>\n    <figcaption>ABD Eri\u015fim Kurulu EV tasar\u0131m k\u0131lavuzuna dayal\u0131 kavramsal \u00fcstten g\u00f6r\u00fcn\u00fcm: 60 in\u00e7lik bir eri\u015fim koridorunu payla\u015fan iki adet 11 \u00d7 20 ft \u015farj istasyonu, ayn\u0131 seviyede 30 \u00d7 48 in\u00e7lik a\u00e7\u0131k zemin alan\u0131 ve engelsiz \u2265 36 in\u00e7lik eri\u015filebilir bir yol. Proje mimar\u0131yla yerel \u015ferit i\u015faretlemelerini, minib\u00fcs park yeri say\u0131lar\u0131n\u0131 ve kald\u0131r\u0131m kesimlerini teyit edin.<\/figcaption>\n  <\/figure>\n\n  <h3 id=\"same-level-pads-and-bollards\">\u015earj cihazlar\u0131n\u0131, park yerine paralel ve bariyerlerden uzak tutun.<\/h3>\n  <p>Eri\u015filebilir \u015farj cihazlar\u0131 tak\u0131n. <strong>ayn\u0131 y\u00fczey y\u00fcksekli\u011fi<\/strong> M\u00fcmk\u00fcn oldu\u011funca, \u015farj alan\u0131n\u0131 ve eri\u015fim koridorunu kald\u0131r\u0131m kenar\u0131na yak\u0131n bir yere yerle\u015ftirin; bunu ya kald\u0131r\u0131m kenar\u0131n\u0131 al\u00e7altarak ya da \u015farj pedini asfalt veya beton zeminle ayn\u0131 hizaya getirerek yapabilirsiniz. H\u0131zl\u0131 \u015farj cihaz\u0131n\u0131 y\u00fckseltilmi\u015f bir kald\u0131r\u0131m kenar\u0131n\u0131n arkas\u0131na monte etmek, kullan\u0131c\u0131lar\u0131n bir seans ba\u015flatmak i\u00e7in bir engelin \u00fczerinden uzanmalar\u0131n\u0131 veya bir rampaya t\u0131rmanmalar\u0131n\u0131 gerektirir. Mevcut bir garajda veya sokak g\u00f6r\u00fcn\u00fcm\u00fcnde yer k\u0131s\u0131tlamalar\u0131 nedeniyle kald\u0131r\u0131m kenar\u0131na montaj zorunluysa, \u015farj cihaz\u0131n\u0131 kald\u0131r\u0131m y\u00fczeyinden 25 cm (10 in\u00e7) mesafede tutun veya yaya trafi\u011fini engellemeden kablonun \u015farj istasyonuna kadar uzanabilmesini sa\u011flayacak \u015fekilde kald\u0131r\u0131mda tam eri\u015filebilir bir yol ve bo\u015f alan sa\u011flay\u0131n.<\/p>\n\n  <p>Koruyucu bariyerler ve beton tekerlek durdurucular, 60 in\u00e7lik eri\u015fim koridoruna, 30 \u00d7 48 in\u00e7lik a\u00e7\u0131k zemin alan\u0131na veya 36 in\u00e7lik y\u00fcr\u00fcme yoluna asla tecav\u00fcz etmemelidir. S\u00fcr\u00fcc\u00fclerin \u00e7elik bir dire\u011fin etraf\u0131ndan dolanmadan \u00f6n veya yan aray\u00fcze d\u00fczg\u00fcn bir \u015fekilde yakla\u015fabilmeleri i\u00e7in bariyerleri da\u011f\u0131t\u0131m cihaz\u0131n\u0131n koruyucu yanlar\u0131na yerle\u015ftirin. Ara\u00e7la yana\u015fma veya <strong>ge\u00e7i\u015fli elektrikli ara\u00e7 \u015farj\u0131<\/strong> \u00c7ekici ara\u00e7lara veya ticari kamyonlara hizmet veren d\u00fczenlemeler i\u00e7in Eri\u015fim Kurulu en az\u0131ndan \u015funu \u00f6nermektedir: <strong>16 fit \u015ferit geni\u015fli\u011fi<\/strong>Ayn\u0131 seviyede da\u011f\u0131t\u0131m \u00fcnitesi eri\u015fimi (veya kald\u0131r\u0131m kenar\u0131 a\u00e7\u0131kl\u0131\u011f\u0131) ve 5 fit uzakta park edilmi\u015f bir araca ula\u015fabilecek kablolar.<\/p>\n\n  <h3 id=\"retrofits-and-parking-counts\">Yenileme \u00e7al\u0131\u015fmalar\u0131nda gerekli engelli park yeri say\u0131s\u0131n\u0131n azalt\u0131lmas\u0131ndan ka\u00e7\u0131n\u0131n.<\/h3>\n  <p>Mevcut bir ticari otoparka \u015farj cihaz\u0131 eklenirken, 2010 ADA Standartlar\u0131 \u00a7202.3.1, eri\u015filebilirli\u011fi yeni in\u015faat minimumlar\u0131n\u0131n alt\u0131na d\u00fc\u015f\u00fcren herhangi bir de\u011fi\u015fikli\u011fi yasaklamaktad\u0131r. Mevcut zorunlu ADA park alan\u0131n\u0131 &quot;Sadece Elektrikli Ara\u00e7 \u015earj\u0131&quot; alan\u0131na d\u00f6n\u00fc\u015ft\u00fcrmek, yanl\u0131\u015fl\u0131kla m\u00fclk\u00fcn Tablo 208.2 uyar\u0131nca zorunlu eri\u015filebilir park yeri say\u0131s\u0131n\u0131n alt\u0131na d\u00fc\u015fmesine neden olabilir. Benzer \u015fekilde, Kaliforniya CBC B\u00f6l\u00fcm 11B (\u00a711B-208.1) uyar\u0131nca, eri\u015filebilir elektrikli ara\u00e7 \u015farj alanlar\u0131, standart eri\u015filebilir park alanlar\u0131na eklenir. Sadece elektrikli ara\u00e7lar i\u00e7in ayr\u0131lm\u0131\u015f alanlar belirlemeden \u00f6nce toplam tesis park yeri say\u0131s\u0131n\u0131 g\u00f6zden ge\u00e7irin.<\/p>\n\n  <h2 id=\"hardware-reach-and-operable-parts\">3. \u015earj Cihaz\u0131n\u0131n Donan\u0131m\u0131n\u0131, Eri\u015fim Mesafesini ve Kablo Uzunlu\u011funu Kontrol Edin<\/h2>\n  <p>Uyumlu \u015feritlere sahip olsa bile, bir \u015farj cihaz\u0131n\u0131n ekran\u0131, \u00f6deme terminali, acil durdurma d\u00fc\u011fmesi veya ba\u011flant\u0131 noktas\u0131 fiziksel eri\u015fimin d\u0131\u015f\u0131nda kal\u0131yorsa veya iki elle a\u011f\u0131r bir kuvvet gerektiriyorsa, ADA eri\u015filebilirlik beklentilerini kar\u015f\u0131layamaz.<\/p>\n\n  <h3 id=\"clear-floor-space-and-reach\">Zeminde yeterli bo\u015f alan oldu\u011fundan ve 48 in\u00e7lik yana uzanma mesafesi kural\u0131na uyuldu\u011fundan emin olun.<\/h3>\n  <figure class=\"evb-article-figure\">\n    <img src=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/ada-ev-stall-clear-floor-space-evb.webp\" width=\"1672\" height=\"941\" loading=\"lazy\" decoding=\"async\" alt=\"\u0130ki adet 11 x 20 ft&#039;lik elektrikli ara\u00e7 \u015farj istasyonunun, 5 ft (60 in\u00e7) geni\u015fli\u011finde bir eri\u015fim koridoru, d\u00fcz beton ge\u00e7i\u015f, d\u0131\u015f bariyerlerle \u00e7evrili engelsiz 30 x 48 in\u00e7 a\u00e7\u0131k zemin alan\u0131 ve bir EVB \u015farj cihaz\u0131nda 15 ila 48 in\u00e7 aras\u0131nda \u00e7al\u0131\u015ft\u0131r\u0131labilir eri\u015fim b\u00f6lgesini g\u00f6steren yerle\u015fim plan\u0131 ve yan eri\u015fim y\u00fckseklik diyagram\u0131.\" \/>\n    <figcaption>Kavramsal m\u00fchendislik yerle\u015fim plan\u0131 ve yan eri\u015fim kotu (2010 ADA Standartlar\u0131 \u00a7305\/\u00a7308\/\u00a7309 ve Eri\u015fim Kurulu EV k\u0131lavuzu). \u0130n\u015faat i\u015flerine ba\u015flamadan \u00f6nce tam platform kotlar\u0131n\u0131 ve UL donan\u0131m \u00e7izimlerini do\u011frulay\u0131n.<\/figcaption>\n  <\/figure>\n  <ul>\n    <li><strong>Zemin veya yer alt\u0131 bo\u015flu\u011funu temizleyin (\u00a7305):<\/strong> En az\u0131ndan \u015funu sa\u011flay\u0131n: <strong>30 \u00d7 48 in\u00e7<\/strong> \u015earj cihaz\u0131n\u0131n \u00e7al\u0131\u015ft\u0131r\u0131labilir par\u00e7alar\u0131na merkezlenmi\u015f, paralel bir yakla\u015f\u0131m i\u00e7in hizalanm\u0131\u015f, sa\u011flam, d\u00fcz (\u2264 1:48 e\u011fim) bir zemin alan\u0131 gereklidir. Alan\u0131n derinli\u011finin yar\u0131s\u0131ndan fazlas\u0131 \u00fc\u00e7 taraftan bariyerler veya bord\u00fcrlerle \u00e7evriliyse, ek geni\u015flik pay\u0131 b\u0131rak\u0131n.<\/li>\n    <li><strong>Yan eri\u015fim y\u00fcksekli\u011fi ve derinli\u011fi (\u00a7308.3.1):<\/strong> Dokunmatik ekran d\u00fc\u011fmeleri, RFID\/temass\u0131z \u00f6deme paneli, \u00f6deme kart\u0131 yuvas\u0131, acil durdurma d\u00fc\u011fmesi ve ba\u011flant\u0131 yuvas\u0131\/kilidi gibi \u00e7al\u0131\u015ft\u0131r\u0131labilir her unsur, belirli bir aral\u0131kta yer almal\u0131d\u0131r. <strong>Minimum 15 in\u00e7 ve maksimum 48 in\u00e7<\/strong> Zemin y\u00fczeyinin \u00fczerinde, \u00f6ne do\u011fru herhangi bir geri \u00e7ekilme veya kald\u0131r\u0131m engeli en fazla \u015fu kadar derinlikte olacak \u015fekilde. <strong>10 in\u00e7<\/strong>.<\/li>\n    <li><strong>Yak\u0131t da\u011f\u0131t\u0131m \u00fcnitesi istisnas\u0131 yok:<\/strong> Eri\u015fim Kurulu, 54 in\u00e7lik yak\u0131t da\u011f\u0131t\u0131m \u00fcnitesi eri\u015fim istisnas\u0131n\u0131n (\u00a7308.3 \u0130stisna 2), borunun yer alt\u0131ndan d\u00fcz bir zemine kadar uzanabildi\u011fi normal EV \u015farj istasyonlar\u0131 i\u00e7in ge\u00e7erli olmad\u0131\u011f\u0131n\u0131 a\u00e7\u0131k\u00e7a teyit etmektedir.<\/li>\n    <li><strong>Tek elle kullan\u0131m ve kuvvet (\u00a7309.4):<\/strong> Kontroller ve ba\u011flant\u0131 kilidi a\u00e7ma mandallar\u0131, s\u0131k\u0131ca kavrama, s\u0131k\u0131\u015ft\u0131rma veya bile\u011fi b\u00fckme gerektirmeden tek elle \u00e7al\u0131\u015ft\u0131r\u0131labilmeli ve \u015fu \u015fartlar\u0131 gerektirmelidir: <strong>en fazla 5 pound (22,2 N) kuvvet<\/strong>.<\/li>\n  <\/ul>\n\n  <h3 id=\"cables-and-communication\">A\u011f\u0131r DC Kablolar\u0131 ve S\u00fcr\u00fcc\u00fc Aray\u00fczlerini Y\u00f6netme<\/h3>\n  <p>Y\u00fcksek g\u00fc\u00e7l\u00fc DC h\u0131zl\u0131 \u015farj kablolar\u0131 \u00f6nemli miktarda bak\u0131r veya so\u011futucu madde a\u011f\u0131rl\u0131\u011f\u0131 ta\u015f\u0131r. Access Board, daha k\u0131sa ve daha a\u011f\u0131r DC h\u0131zl\u0131 \u015farj kablolar\u0131n\u0131n en az\u0131ndan ara\u00e7 giri\u015fine ula\u015fabilecek uzunlukta olmas\u0131n\u0131 \u00f6nermektedir. <strong>60 in\u00e7 (5 fit) uzakl\u0131kta<\/strong>Ayr\u0131ca, kablo y\u00f6netim sistemlerinin, yukar\u0131da \u00e7\u0131k\u0131nt\u0131 yapan nesneler olu\u015fturmadan (\u00a7307) veya kablolar\u0131 bariyerlere s\u0131k\u0131\u015ft\u0131rmadan gev\u015fek kablolar\u0131 yerden uzak tuttu\u011funu belirtir. Yak\u0131n ve uzak taraftaki ara\u00e7 giri\u015fleri boyunca detayl\u0131 y\u00f6nlendirme \u015femalar\u0131 ve geri \u00e7ekme mekanizmas\u0131 kabul testleri i\u00e7in EVB&#039;nin ilgili k\u0131lavuzuna bak\u0131n. <a href=\"https:\/\/www.evb.com\/tr\/ev-charger-cable-management\/\">ticari DC kablo y\u00f6netimi k\u0131lavuzu<\/a>.<\/p>\n\n  <p>Her halka a\u00e7\u0131k \u015farj istasyonu ayr\u0131ca hareket kabiliyeti gerektirmeyen ileti\u015fim eri\u015fimini de desteklemelidir: y\u00fcksek kontrastl\u0131, parlamaya dayan\u0131kl\u0131 ekranlar, yaln\u0131zca renge dayanmayan durum g\u00f6stergeleri ve net servis\/yard\u0131m ileti\u015fim se\u00e7enekleri. 23 CFR B\u00f6l\u00fcm 680 kapsam\u0131nda finanse edilen projeler i\u00e7in operat\u00f6rler, temass\u0131z banka\/kredi kart\u0131 \u00f6demesi ve otomatik \u00fccretsiz telefon veya SMS \u00f6deme se\u00e7ene\u011fi (\u00a7680.106(f)), eri\u015filebilir \u00e7ok dilli sorun bildirimi (\u00a7680.106(k)) ve \u00fc\u00e7\u00fcnc\u00fc taraf API eri\u015filebilirlik alanlar\u0131 (\u00f6rne\u011fin, bekleme yeri durumu) (\u00a7680.116(c)) sa\u011flamal\u0131d\u0131r.<\/p>\n\n  <h2 id=\"evb-hardware-layout-considerations\">4. \u015earj Cihaz\u0131 Mimarisini Eri\u015filebilir Durak Geometrisine Uyarlay\u0131n<\/h2>\n  <p>EVB&#039;nin \u00fcr\u00fcn gam\u0131nda hepsi bir arada h\u0131zl\u0131 \u015farj cihaz\u0131 ile b\u00f6l\u00fcnm\u00fc\u015f mimariye sahip \u00fcnite aras\u0131nda se\u00e7im yapmak <a href=\"https:\/\/www.evb.com\/tr\/by-charging-type\/evb-dc-ev-charging-solutions\/\">ticari DC EV \u015farj \u00e7\u00f6z\u00fcmleri<\/a> Bu durum, eri\u015filebilir bir kabinin yan\u0131nda ne kadar bo\u015f zemin alan\u0131 kald\u0131\u011f\u0131n\u0131 do\u011frudan etkiler. Bir kabinin ba\u015f\u0131na do\u011frudan yerle\u015ftirilen b\u00fcy\u00fck entegre g\u00fc\u00e7 kabinleri, dar adalar\u0131 kalabal\u0131kla\u015ft\u0131rabilir, bariyer aral\u0131klar\u0131n\u0131 engelleyebilir veya bir arac\u0131n etraf\u0131ndan daha uzun kablo g\u00fczergahlar\u0131n\u0131n ge\u00e7mesine neden olabilir.<\/p>\n\n  <p>Yay\u0131nlanan EVB donan\u0131m \u00f6zellikleri, g\u00fc\u00e7 d\u00f6n\u00fc\u015ft\u00fcrme i\u015flemini s\u00fcr\u00fcc\u00fcye bakan terminalden ay\u0131rman\u0131n dar ticari alanlarda neden faydal\u0131 oldu\u011funu g\u00f6stermektedir:<\/p>\n  <ul>\n    <li><strong>B\u00f6l\u00fcnm\u00fc\u015f terminal ve g\u00fc\u00e7 kabini kaplad\u0131\u011f\u0131 alan:<\/strong> EVB&#039;nin <a href=\"https:\/\/www.evb.com\/tr\/product-item\/720kw-liquid-cooling-dc-ev-charging-stations-with-independent-duct\/\">BSDCE b\u00f6l\u00fcnm\u00fc\u015f DC mimarisi<\/a>Do\u011frultucu kabininin \u00f6l\u00e7\u00fcleri \u015fu \u015fekildedir: <strong>1700 \u00d7 1000 \u00d7 2150 mm<\/strong> (\u2264 1100 kg), ince \u015farj terminali ise \u015fu \u00f6l\u00e7\u00fclerdedir: <strong>600 \u00d7 230 \u00d7 1700 mm<\/strong> (\u2264 110 kg) 21 in\u00e7 dokunmatik ekranl\u0131 ve 500 A&#039;ya kadar iste\u011fe ba\u011fl\u0131 s\u0131v\u0131 so\u011futmal\u0131 kablolarla daha ince ve hafif kullan\u0131m i\u00e7in tasarlanm\u0131\u015ft\u0131r. 1 metre derinli\u011findeki g\u00fc\u00e7 kabinini bir yard\u0131mc\u0131 alana ay\u0131rmak, eri\u015filebilir koridorun yak\u0131n\u0131nda yaln\u0131zca 230 mm derinli\u011finde bir da\u011f\u0131t\u0131c\u0131 alan\u0131 b\u0131rak\u0131r. <em>(Not: BSDCE&#039;nin yay\u0131nlad\u0131\u011f\u0131 belgede uluslararas\u0131 pazarlar i\u00e7in 380\u2013415 V AC giri\u015f voltaj\u0131 belirtilmi\u015ftir; ABD&#039;li al\u0131c\u0131lar Kuzey Amerika UL onayl\u0131 b\u00f6l\u00fcnm\u00fc\u015f veya entegre konfig\u00fcrasyonlar\u0131 talep etmelidir.)<\/em><\/li>\n    <li><strong>Kuzey Amerika&#039;da kullan\u0131lan hepsi bir arada DC h\u0131zl\u0131 \u015farj cihazlar\u0131:<\/strong> ABD&#039;deki ba\u011f\u0131ms\u0131z \u00fcniteler gerektiren tesisler i\u00e7in EVB&#039;nin <a href=\"https:\/\/www.evb.com\/tr\/product-item\/floor-mounted-dc-2-guns-ev-dc-fast-charger\/\">BDC 60\u2013320 kW serisi<\/a> (ve Kuzey Amerika UL ve ENERGY STAR sertifikal\u0131 BDC-D-UL konfig\u00fcrasyonlar\u0131) \u00e7ift tabancal\u0131 CCS1\/NACS se\u00e7eneklerini, POS kart \u00f6demesini, RFID eri\u015fimini, 21 in\u00e7 veya 7\/12 in\u00e7 ekran se\u00e7eneklerini, OCPP 1.6J\/2.0.1&#039;i destekler ve <strong>5 metrelik standart veya \u00f6zel \u00f6l\u00e7\u00fclerde kablo uzunluklar\u0131<\/strong> Kablo y\u00f6netimi ile. Yay\u0131nlanm\u0131\u015f bir makalede <a href=\"https:\/\/www.evb.com\/tr\/project\/usa-dc-fast-charging-21inch-display\/\">Miami, ABD&#039;de g\u00f6revlendirme<\/a>EVB, d\u0131\u015f mekanlarda net ekran g\u00f6r\u00fcn\u00fcrl\u00fc\u011f\u00fcn\u00fc ve \u00e7ift b\u00f6lmeli esnekli\u011fi \u00f6nceliklendirmek amac\u0131yla 21 in\u00e7lik dokunmatik ekrana ve IP55 koruma s\u0131n\u0131f\u0131na sahip 240 kW&#039;l\u0131k \u00e7ift \u015farjl\u0131 DC h\u0131zl\u0131 \u015farj sistemi tedarik etti.<\/li>\n  <\/ul>\n\n  <p>Montaj platformlar\u0131, temel y\u00fckseklikleri ve iste\u011fe ba\u011fl\u0131 \u00f6deme terminalleri proje sipari\u015fine g\u00f6re de\u011fi\u015fti\u011finden, yay\u0131nlanan teknik \u00f6zellik sayfalar\u0131 tek ba\u015f\u0131na sahada ADA eri\u015fim uyumlulu\u011funu garanti etmez. Eri\u015filebilir bir b\u00f6lme i\u00e7in in\u015faat \u00e7izimleri yay\u0131nlamadan \u00f6nce, sipari\u015f etti\u011finiz EVB modeli i\u00e7in tam boyut ve y\u00fckseklik \u00e7izimini isteyin ve bitmi\u015f platform y\u00fcksekli\u011finin dokunmatik ekran\u0131n etkile\u015fimli kontrollerini, POS\/RFID okuyucusunu, acil durdurma d\u00fc\u011fmesini ve konekt\u00f6r yuvas\u0131n\u0131 ayn\u0131 hizada veya alt\u0131nda tuttu\u011funu do\u011frulay\u0131n. <strong>Zeminden 48 in\u00e7 yukar\u0131da<\/strong>.<\/p>\n\n  <div class=\"evb-callout\">\n    <h3>Engelli eri\u015fimine uygun park yerleri i\u00e7in \u015farj cihaz\u0131 sipari\u015f etmeden \u00f6nce EVB&#039;ye ne g\u00f6ndermelisiniz?<\/h3>\n    <p>\u0130\u015faretlenmi\u015f park alan\u0131 d\u00fczeninizi, gerekli eyalet\/yerel park yeri say\u0131s\u0131n\u0131 (\u00f6rne\u011fin Kaliforniya CBC 11B ile standart ADA temel \u00e7izgisi aras\u0131ndaki fark gibi), planlanan zemin ve kald\u0131r\u0131m y\u00fcksekli\u011fini, park yeri ba\u015f\u0131na hedeflenen g\u00fcc\u00fc ve \u00f6deme\/kablo y\u00f6netimi gereksinimlerini payla\u015f\u0131n. EVB&#039;nin m\u00fchendislik ekibi, in\u015faat \u00e7al\u0131\u015fmalar\u0131 ba\u015flamadan \u00f6nce sipari\u015f edilebilir ABD UL\/ENERGY STAR konfig\u00fcrasyonlar\u0131n\u0131, kabin ayak izlerini, kablo uzunlu\u011fu se\u00e7eneklerini ve y\u00fckseklik \u00e7izimlerini onaylayabilir. <a href=\"https:\/\/www.evb.com\/tr\/by-charging-type\/evb-dc-ev-charging-solutions\/\">EVB&#039;nin ticari DC elektrikli ara\u00e7 \u015farj \u00e7\u00f6z\u00fcmlerini ke\u015ffedin.<\/a> veya <a href=\"https:\/\/www.evb.com\/tr\/by-industry\/commercial-parking-charging\/\">ticari otopark kurulumlar\u0131n\u0131 inceleyin<\/a>.<\/p>\n  <\/div>\n\n  <h2 id=\"handover-verification\">5. A\u00e7madan \u00d6nce Yerinde Eri\u015filebilirli\u011fi Do\u011frulay\u0131n<\/h2>\n  <p>Eri\u015filebilirlik uyumlulu\u011fu, asfalt kaplama, beton d\u00f6k\u00fcm\u00fc, bariyer montaj\u0131 ve \u015ferit i\u015faretlemesinden sonra sahada kazan\u0131l\u0131r veya kaybedilir. EVB&#039;nin a\u015fa\u011f\u0131daki be\u015f fiziksel kontrol\u00fcne ek olarak \u015funlar\u0131 da ekleyin: <a href=\"https:\/\/www.evb.com\/tr\/ev-charging-station-commissioning-checklist\/\">Elektrikli ara\u00e7 \u015farj istasyonu devreye alma kontrol listesi<\/a> Ve <a href=\"https:\/\/www.evb.com\/tr\/ev-charger-installation-requirements\/\">saha kurulum gereksinimleri<\/a> S\u00fcr\u00fcc\u00fclerin kullan\u0131m\u0131na a\u00e7\u0131lmadan \u00f6nce:<\/p>\n\n  <ol>\n    <li><strong>Her iki y\u00f6ndeki nihai e\u011fimleri \u00f6l\u00e7\u00fcn:<\/strong> Drenaj e\u011fimi veya oturma nedeniyle bitmi\u015f y\u00fczeyin 1:48 (2.08%) oran\u0131n\u0131 a\u015fmad\u0131\u011f\u0131n\u0131 do\u011frulamak i\u00e7in, eri\u015filebilir \u015farj kabini, 60 in\u00e7lik eri\u015fim koridoru ve 30 \u00d7 48 in\u00e7lik a\u00e7\u0131k zemin alan\u0131nda dijital bir seviye kullan\u0131n.<\/li>\n    <li><strong>Yerle\u015ftirilen bariyerlerle koridor ve g\u00fczergah a\u00e7\u0131kl\u0131\u011f\u0131n\u0131 kontrol edin:<\/strong> 60 in\u00e7lik eri\u015fim koridoruna, 30 \u00d7 48 in\u00e7lik alana veya tesis giri\u015fine giden \u2265 36 in\u00e7lik yola herhangi bir bariyer, tekerlek durdurucu, trafo platformu veya i\u015faret dire\u011finin girmedi\u011fini do\u011frulay\u0131n.<\/li>\n    <li><strong>Her bir hareketli par\u00e7an\u0131n y\u00fcksekli\u011fini bitmi\u015f tabandan itibaren \u00f6l\u00e7\u00fcn:<\/strong> En \u00fcstteki etkile\u015fimli dokunmatik ekran kontrol\u00fcn\u00fcn, kart okuyucu\/dokunmatik alan\u0131n, acil durdurma d\u00fc\u011fmesinin ve ba\u011flant\u0131 serbest b\u0131rakma mandal\u0131n\u0131n, zemin y\u00fczeyinden 15 ila 48 in\u00e7 yukar\u0131da ve engelsiz kenardan 10 in\u00e7 mesafede oldu\u011fundan emin olun.<\/li>\n    <li><strong>Ara\u00e7lar park halindeyken kablo eri\u015fim mesafesini ve depolama y\u00fcksekli\u011fini test edin:<\/strong> Kablolar\u0131, eri\u015fim koridoru ve yaya yolunda kablo gev\u015fekli\u011fi olmamas\u0131na dikkat ederek, yak\u0131n ve uzak taraftaki giri\u015flere tak\u0131n, ard\u0131ndan konekt\u00f6r\u00fcn yuvas\u0131na veya deste\u011fine d\u00fczg\u00fcn bir \u015fekilde geri d\u00f6nd\u00fc\u011f\u00fcn\u00fc do\u011frulay\u0131n.<\/li>\n    <li><strong>\u0130\u015faretleri, ayd\u0131nlatmay\u0131 ve a\u011f eri\u015filebilirli\u011fi etiketlerini do\u011frulay\u0131n:<\/strong> Dik park yeri i\u015faretlerinin yerel y\u00f6netmeli\u011fe uygun oldu\u011fundan (&quot;en son kullan\u0131n&quot; veya gerekti\u011finde ISA), ayd\u0131nlatman\u0131n geceleyin aray\u00fcz\u00fc ve kilidi ayd\u0131nlatt\u0131\u011f\u0131ndan ve uygulama\/OCPP listelerinin eri\u015filebilir park yeri durumunu ve \u00f6deme se\u00e7eneklerini do\u011fru \u015fekilde g\u00f6sterdi\u011finden emin olun.<\/li>\n  <\/ol>\n\n  <h2 id=\"frequently-asked-questions\">S\u0131k\u00e7a Sorulan Sorular<\/h2>\n  <h3 id=\"faq-2024-nprm\">ABD Eri\u015fim Kurulu&#039;nun 2024 tarihli elektrikli ara\u00e7 \u015farj cihaz\u0131 kural\u0131 zorunlu federal yasa haline geldi mi?<\/h3>\n  <p>Hay\u0131r. Eri\u015fim Kurulu 3 Eyl\u00fcl 2024 tarihinde bir Kural Koyma Teklifi Bildirimi yay\u0131nlam\u0131\u015f olsa da, 2027 Mali Y\u0131l\u0131 Kurum Performans Plan\u0131, kural koyma s\u00fcrecinin pasif duruma getirildi\u011fini do\u011frulamaktad\u0131r. Projelerin, y\u00fcr\u00fcrl\u00fckte olan 2010 ADA Standartlar\u0131na, II\/III. Ba\u015fl\u0131k &quot;makul say\u0131&quot; y\u00fck\u00fcml\u00fcl\u00fcklerine, federal fonlarla destekleniyorsa 23 CFR B\u00f6l\u00fcm 680&#039;e ve uygulanabilir eyalet veya belediye bina kodlar\u0131na uymas\u0131 gerekmektedir.<\/p>\n\n  <h3 id=\"faq-convert-ada-stalls\">Mevcut engelli park yerlerini elektrikli ara\u00e7 \u015farj alanlar\u0131na d\u00f6n\u00fc\u015ft\u00fcrebilir miyim?<\/h3>\n  <p>Engelli park yerlerinin yaln\u0131zca elektrikli ara\u00e7 \u015farj istasyonlar\u0131na d\u00f6n\u00fc\u015ft\u00fcr\u00fclmesi genellikle \u00f6nerilmez \u00e7\u00fcnk\u00fc 2010 ADA Standartlar\u0131 \u00a7202.3.1, eri\u015filebilirli\u011fi minimum gereksinimlerin alt\u0131na d\u00fc\u015f\u00fcren de\u011fi\u015fiklikleri yasaklamaktad\u0131r. Mevcut bir engelli park yeri yaln\u0131zca elektrikli ara\u00e7 \u015farj\u0131 i\u00e7in ayr\u0131lm\u0131\u015fsa, Tablo 208.2 park oranlar\u0131n\u0131 yeniden hesaplaman\u0131z ve ba\u015fka bir yere yedek engelli park yeri eklemeniz gerekebilir; Kaliforniya gibi eyaletlerde (CBC \u00a711B-208.1), engelli elektrikli ara\u00e7 park yerleri standart engelli park yerlerine ek olarak de\u011ferlendirilir.<\/p>\n\n  <h3 id=\"faq-isa-vs-use-last\">Eri\u015filebilir elektrikli ara\u00e7 \u015farj istasyonlar\u0131nda ISA sembol\u00fc m\u00fc yoksa &quot;En Son Kullan\u0131n&quot; i\u015faretleri mi kullan\u0131lmal\u0131?<\/h3>\n  <p>\u00d6ncelikle eyalet ve yerel y\u00f6netmelikleri kontrol edin: Kaliforniya gibi baz\u0131 yetki alanlar\u0131, belirlenmi\u015f eri\u015filebilir elektrikli ara\u00e7 park yerleri i\u00e7in \u00f6zel ISA i\u015faretlemesi ve dik levhalar zorunlu k\u0131lmaktad\u0131r. Eyalet veya yerel yasa ISA&#039;y\u0131 zorunlu k\u0131lm\u0131yorsa, ABD Eri\u015fim Kurulu, \u015farj cihazlar\u0131n\u0131n kullan\u0131lmadan kalmamas\u0131 i\u00e7in k\u00fc\u00e7\u00fck istasyonlarda yaln\u0131zca ISA rezervasyonundan ka\u00e7\u0131n\u0131lmas\u0131n\u0131 ve bunun yerine hareket kabiliyetine uygun park yeri boyutlar\u0131yla birlikte &quot;son kullan\u0131n&quot; levhalar\u0131n\u0131n kullan\u0131lmas\u0131n\u0131 \u00f6nermektedir.<\/p>\n\n  <h2 id=\"references\">Referanslar<\/h2>\n  <p>17 Kas\u0131m 2026 tarihinde eri\u015fildi.<\/p>\n  <ul class=\"evb-sources\">\n    <li><a href=\"https:\/\/www.access-board.gov\/tad\/ev\/\" rel=\"nofollow\">ABD Eri\u015filebilirlik Kurulu, Eri\u015filebilir Elektrikli Ara\u00e7 \u015earj \u0130stasyonlar\u0131 i\u00e7in Tasar\u0131m \u00d6nerileri<\/a><\/li>\n    <li><a href=\"https:\/\/www.access-board.gov\/about\/cj2027.html\" rel=\"nofollow\">ABD Eri\u015fim Kurulu, 2027 Mali Y\u0131l\u0131 Kurum Performans Plan\u0131 (Elektrikli Ara\u00e7 \u015earj \u0130stasyonlar\u0131 d\u00fczenleme durumu)<\/a><\/li>\n    <li><a href=\"https:\/\/www.ada.gov\/law-and-regs\/design-standards\/2010-stds\/\" rel=\"nofollow\">ABD Adalet Bakanl\u0131\u011f\u0131, 2010 Eri\u015filebilir Tasar\u0131m i\u00e7in ADA Standartlar\u0131<\/a><\/li>\n    <li><a href=\"https:\/\/www.access-board.gov\/ada\/\" rel=\"nofollow\">ABD Eri\u015filebilirlik Kurulu, ADA Eri\u015filebilirlik Standartlar\u0131 (\u00a7202.3, \u00a7305, \u00a7308, \u00a7309, \u00a7402, \u00a7403)<\/a><\/li>\n    <li><a href=\"https:\/\/www.ecfr.gov\/current\/title-23\/chapter-I\/subchapter-G\/part-680\" rel=\"nofollow\">23 CFR B\u00f6l\u00fcm 680, Ulusal Elektrikli Ara\u00e7 Altyap\u0131 Standartlar\u0131 ve Gereksinimleri (\u00a7680.106, \u00a7680.116)<\/a><\/li>\n    <li><a href=\"https:\/\/www.3c-ren.org\/calgreen-compliance-for-ev-charging\/\" rel=\"nofollow\">3C-REN, CALGreen, Elektrikli Ara\u00e7 \u015earj\u0131 i\u00e7in Eri\u015fim Uyumlulu\u011funu Entegre Ediyor (California CBC B\u00f6l\u00fcm 11B Tablo 11B-228.3.2.1 ve \u00a711B-208.1&#039;e at\u0131fta bulunarak)<\/a><\/li>\n    <li><a href=\"https:\/\/www.evb.com\/tr\/product-item\/720kw-liquid-cooling-dc-ev-charging-stations-with-independent-duct\/\">EVB, BSDCE Zemine Monte Edilen B\u00f6lmeli DC Elektrikli Ara\u00e7 \u015earj Cihaz\u0131 \u00d6zellikleri<\/a><\/li>\n    <li><a href=\"https:\/\/www.evb.com\/tr\/product-item\/floor-mounted-dc-2-guns-ev-dc-fast-charger\/\">EVB, BDC 60kW\u2013320kW Zemine Monte Edilen 2 \u015earj Cihazl\u0131 DC H\u0131zl\u0131 \u015earj Cihaz\u0131<\/a><\/li>\n    <li><a href=\"https:\/\/www.evb.com\/tr\/project\/usa-dc-fast-charging-21inch-display\/\">EVB, Miami, ABD 21 \u0130n\u00e7 Dokunmatik Ekranl\u0131 DC H\u0131zl\u0131 \u015earj Projesi<\/a><\/li>\n  <\/ul>\n<\/article>\n\n\n\n\n<p><\/p>","protected":false},"excerpt":{"rendered":"<p>EVB.COM \u00b7 Author: EVB Charging Solutions Team \u00b7 Updated November 2026 \u00b7 14-minute read \u00b7 Commercial EV Charging \u00b7 DC Fast Charging \u00b7 Site Accessibility U.S. commercial EV charging stations must meet the active 2010 ADA Standards for Accessible Design alongside any state, local, or public-funding rules that apply to the project. The U.S. Access [&hellip;]<\/p>","protected":false},"author":3,"featured_media":44788,"comment_status":"open","ping_status":"open","sticky":false,"template":"","format":"standard","meta":{"footnotes":""},"categories":[1],"tags":[214,205],"class_list":["post-44790","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-product-dynamics","tag-commercial-ev-charging","tag-dc-fast-charging"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.4 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ADA EV Charging Requirements for U.S. Commercial Sites - EVB<\/title>\n<meta name=\"description\" content=\"Plan ADA-compliant EV charging spaces for U.S. commercial sites: current federal rules, 2024 NPRM status, stall layout, reach ranges, and hardware checks.\" \/>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.evb.com\/tr\/ada-ev-charging-requirements\/\" \/>\n<meta property=\"og:locale\" content=\"tr_TR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ADA EV Charging Requirements for U.S. Commercial Sites - EVB\" \/>\n<meta property=\"og:description\" content=\"Plan ADA-compliant EV charging spaces for U.S. commercial sites: current federal rules, 2024 NPRM status, stall layout, reach ranges, and hardware checks.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.evb.com\/tr\/ada-ev-charging-requirements\/\" \/>\n<meta property=\"og:site_name\" content=\"EVB\" \/>\n<meta property=\"article:published_time\" content=\"2026-11-17T06:23:07+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2026-11-17T08:08:59+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/ada-ev-charging-requirements-cover-evb.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"1672\" \/>\n\t<meta property=\"og:image:height\" content=\"941\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"author\" content=\"EVB Editorial Team\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Yazan:\" \/>\n\t<meta name=\"twitter:data1\" content=\"EVB Editorial Team\" \/>\n\t<meta name=\"twitter:label2\" content=\"Tahmini okuma s\u00fcresi\" \/>\n\t<meta name=\"twitter:data2\" content=\"13 dakika\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/\"},\"author\":{\"name\":\"EVB Editorial Team\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/person\\\/fe8f0137976034abdfd2ae4f8c5682d0\"},\"headline\":\"ADA EV Charging Requirements for U.S. Commercial Sites\",\"datePublished\":\"2026-11-17T06:23:07+00:00\",\"dateModified\":\"2026-11-17T08:08:59+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/\"},\"wordCount\":2665,\"commentCount\":0,\"publisher\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/ada-ev-charging-requirements-cover-evb.webp\",\"keywords\":[\"commercial EV charging\",\"DC fast charging\"],\"articleSection\":[\"Product Dynamics\"],\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"CommentAction\",\"name\":\"Comment\",\"target\":[\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/#respond\"]}]},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/\",\"url\":\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/\",\"name\":\"ADA EV Charging Requirements for U.S. Commercial Sites - EVB\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/ada-ev-charging-requirements-cover-evb.webp\",\"datePublished\":\"2026-11-17T06:23:07+00:00\",\"dateModified\":\"2026-11-17T08:08:59+00:00\",\"description\":\"Plan ADA-compliant EV charging spaces for U.S. commercial sites: current federal rules, 2024 NPRM status, stall layout, reach ranges, and hardware checks.\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/#breadcrumb\"},\"inLanguage\":\"tr\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/ada-ev-charging-requirements-cover-evb.webp\",\"contentUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2026\\\/11\\\/ada-ev-charging-requirements-cover-evb.webp\",\"width\":1672,\"height\":941,\"caption\":\"ada ev charging requirements cover evb\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/ada-ev-charging-requirements\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.evb.com\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ADA EV Charging Requirements for U.S. Commercial Sites\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#website\",\"url\":\"https:\\\/\\\/www.evb.com\\\/\",\"name\":\"EVB\",\"description\":\"Smart EV Charging &amp; Energy Storage Solutions\",\"publisher\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.evb.com\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"tr\"},{\"@type\":\"Organization\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#organization\",\"name\":\"EVB\",\"url\":\"https:\\\/\\\/www.evb.com\\\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/logo\\\/image\\\/\",\"url\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/evb-3.png\",\"contentUrl\":\"https:\\\/\\\/www.evb.com\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/evb-3.png\",\"width\":605,\"height\":626,\"caption\":\"EVB\"},\"image\":{\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/logo\\\/image\\\/\"}},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.evb.com\\\/#\\\/schema\\\/person\\\/fe8f0137976034abdfd2ae4f8c5682d0\",\"name\":\"EVB Editorial Team\",\"image\":{\"@type\":\"ImageObject\",\"inLanguage\":\"tr\",\"@id\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"url\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"contentUrl\":\"https:\\\/\\\/secure.gravatar.com\\\/avatar\\\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g\",\"caption\":\"EVB Editorial Team\"},\"description\":\"The EVB Editorial Team creates expert content on EV charging infrastructure, commercial charging solutions, energy storage integration, and global charging projects, with input from EVB product and engineering specialists.\",\"sameAs\":[\"https:\\\/\\\/www.evb.com\\\/\"]}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ADA EV Charging Requirements for U.S. Commercial Sites - EVB","description":"Plan ADA-compliant EV charging spaces for U.S. commercial sites: current federal rules, 2024 NPRM status, stall layout, reach ranges, and hardware checks.","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.evb.com\/tr\/ada-ev-charging-requirements\/","og_locale":"tr_TR","og_type":"article","og_title":"ADA EV Charging Requirements for U.S. Commercial Sites - EVB","og_description":"Plan ADA-compliant EV charging spaces for U.S. commercial sites: current federal rules, 2024 NPRM status, stall layout, reach ranges, and hardware checks.","og_url":"https:\/\/www.evb.com\/tr\/ada-ev-charging-requirements\/","og_site_name":"EVB","article_published_time":"2026-11-17T06:23:07+00:00","article_modified_time":"2026-11-17T08:08:59+00:00","og_image":[{"width":1672,"height":941,"url":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/ada-ev-charging-requirements-cover-evb.webp","type":"image\/webp"}],"author":"EVB Editorial Team","twitter_card":"summary_large_image","twitter_misc":{"Yazan:":"EVB Editorial Team","Tahmini okuma s\u00fcresi":"13 dakika"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.evb.com\/ada-ev-charging-requirements\/#article","isPartOf":{"@id":"https:\/\/www.evb.com\/ada-ev-charging-requirements\/"},"author":{"name":"EVB Editorial Team","@id":"https:\/\/www.evb.com\/#\/schema\/person\/fe8f0137976034abdfd2ae4f8c5682d0"},"headline":"ADA EV Charging Requirements for U.S. Commercial Sites","datePublished":"2026-11-17T06:23:07+00:00","dateModified":"2026-11-17T08:08:59+00:00","mainEntityOfPage":{"@id":"https:\/\/www.evb.com\/ada-ev-charging-requirements\/"},"wordCount":2665,"commentCount":0,"publisher":{"@id":"https:\/\/www.evb.com\/#organization"},"image":{"@id":"https:\/\/www.evb.com\/ada-ev-charging-requirements\/#primaryimage"},"thumbnailUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/ada-ev-charging-requirements-cover-evb.webp","keywords":["commercial EV charging","DC fast charging"],"articleSection":["Product Dynamics"],"inLanguage":"tr","potentialAction":[{"@type":"CommentAction","name":"Comment","target":["https:\/\/www.evb.com\/ada-ev-charging-requirements\/#respond"]}]},{"@type":"WebPage","@id":"https:\/\/www.evb.com\/ada-ev-charging-requirements\/","url":"https:\/\/www.evb.com\/ada-ev-charging-requirements\/","name":"ADA EV Charging Requirements for U.S. Commercial Sites - EVB","isPartOf":{"@id":"https:\/\/www.evb.com\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.evb.com\/ada-ev-charging-requirements\/#primaryimage"},"image":{"@id":"https:\/\/www.evb.com\/ada-ev-charging-requirements\/#primaryimage"},"thumbnailUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/ada-ev-charging-requirements-cover-evb.webp","datePublished":"2026-11-17T06:23:07+00:00","dateModified":"2026-11-17T08:08:59+00:00","description":"Plan ADA-compliant EV charging spaces for U.S. commercial sites: current federal rules, 2024 NPRM status, stall layout, reach ranges, and hardware checks.","breadcrumb":{"@id":"https:\/\/www.evb.com\/ada-ev-charging-requirements\/#breadcrumb"},"inLanguage":"tr","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.evb.com\/ada-ev-charging-requirements\/"]}]},{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/www.evb.com\/ada-ev-charging-requirements\/#primaryimage","url":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/ada-ev-charging-requirements-cover-evb.webp","contentUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2026\/11\/ada-ev-charging-requirements-cover-evb.webp","width":1672,"height":941,"caption":"ada ev charging requirements cover evb"},{"@type":"BreadcrumbList","@id":"https:\/\/www.evb.com\/ada-ev-charging-requirements\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.evb.com\/"},{"@type":"ListItem","position":2,"name":"ADA EV Charging Requirements for U.S. Commercial Sites"}]},{"@type":"WebSite","@id":"https:\/\/www.evb.com\/#website","url":"https:\/\/www.evb.com\/","name":"EVB","description":"Smart EV Charging &amp; Energy Storage Solutions","publisher":{"@id":"https:\/\/www.evb.com\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.evb.com\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"tr"},{"@type":"Organization","@id":"https:\/\/www.evb.com\/#organization","name":"EVB","url":"https:\/\/www.evb.com\/","logo":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/www.evb.com\/#\/schema\/logo\/image\/","url":"https:\/\/www.evb.com\/wp-content\/uploads\/2021\/03\/evb-3.png","contentUrl":"https:\/\/www.evb.com\/wp-content\/uploads\/2021\/03\/evb-3.png","width":605,"height":626,"caption":"EVB"},"image":{"@id":"https:\/\/www.evb.com\/#\/schema\/logo\/image\/"}},{"@type":"Person","@id":"https:\/\/www.evb.com\/#\/schema\/person\/fe8f0137976034abdfd2ae4f8c5682d0","name":"EVB Editorial Team","image":{"@type":"ImageObject","inLanguage":"tr","@id":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","url":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","contentUrl":"https:\/\/secure.gravatar.com\/avatar\/6919cc4e91e3745783933e1263b15b0bed21b5e46f2b1e21643aa8b29240d0f7?s=96&d=mm&r=g","caption":"EVB Editorial Team"},"description":"The EVB Editorial Team creates expert content on EV charging infrastructure, commercial charging solutions, energy storage integration, and global charging projects, with input from EVB product and engineering specialists.","sameAs":["https:\/\/www.evb.com\/"]}]}},"_links":{"self":[{"href":"https:\/\/www.evb.com\/tr\/wp-json\/wp\/v2\/posts\/44790","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.evb.com\/tr\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.evb.com\/tr\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.evb.com\/tr\/wp-json\/wp\/v2\/users\/3"}],"replies":[{"embeddable":true,"href":"https:\/\/www.evb.com\/tr\/wp-json\/wp\/v2\/comments?post=44790"}],"version-history":[{"count":3,"href":"https:\/\/www.evb.com\/tr\/wp-json\/wp\/v2\/posts\/44790\/revisions"}],"predecessor-version":[{"id":44797,"href":"https:\/\/www.evb.com\/tr\/wp-json\/wp\/v2\/posts\/44790\/revisions\/44797"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.evb.com\/tr\/wp-json\/wp\/v2\/media\/44788"}],"wp:attachment":[{"href":"https:\/\/www.evb.com\/tr\/wp-json\/wp\/v2\/media?parent=44790"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.evb.com\/tr\/wp-json\/wp\/v2\/categories?post=44790"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.evb.com\/tr\/wp-json\/wp\/v2\/tags?post=44790"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}